proceq GS8000 Pro Subsurface Mapping User Guide

June 17, 2024
proceq

GS8000 Pro Subsurface Mapping

proceq GS8000 Pro Subsurface Mapping Quick Start Guide & Product Certificates

Proceq GS8000 Pro

A|
---|---
B|
C|
D|
E|
F|
G|
H|
I|
J|
K|

Included
Optionalproceq GS8000 Pro Subsurface Mapping - Fig 1proceq GS8000 Pro Subsurface Mapping - Fig 2 a. The product can be operated while powered by the battery pack, an off-the- shelf power bank (5V DC 2A), or a USB 2.0 charger and USB C Charging Cable.proceq GS8000 Pro Subsurface Mapping - Fig 3 b. Insert the AA rechargeable batteries while ensuring correct polarity. Alternatively, you can use non-rechargeable AA batteries. Warning: do not charge non-rechargeable AA batteries!proceq GS8000 Pro Subsurface Mapping -
Fig 4

c. During storage for longer than 3 months, do not leave the batteries in the battery pack.
Remove by following the reverse procedure.proceq GS8000 Pro Subsurface
Mapping - Fig 5d. Green: charging; off: charging complete; red: AA cells incorrectly inserted or temperature limit exceeded (wait or disconnect)
(2.1) Optional assemblyproceq GS8000 Pro Subsurface Mapping - Fig
6proceq GS8000 Pro Subsurface Mapping - Fig
7 .e Take care to avoid injury to fingers when connecting.
f. Verify that the battery pack is securely connected to your base unit

4.Create your account:
Open your browser and type: https://www.screeningeagle.com/
Then Select te voice: Workspace on the right up corner .
In alternative scan the QR-Code. 5. Select the voice:
Workspace on the right up cornerproceq GS8000 Pro Subsurface Mapping - Fig
86. You have been redirected to how workspace page.
Press on the botton: Create an Accountproceq GS8000 Pro Subsurface Mapping -
Fig 97. Insert your data and Submit.
The approval process will take few minutesproceq GS8000 Pro Subsurface
Mapping - Fig 108. Download the app “Flaw Detector Live” on the Apple® App Storeproceq GS8000 Pro Subsurface Mapping - Fig
11proceq GS8000 Pro Subsurface Mapping - Fig
12https://www.proceq.com
g. Scanning the QR code with an Internet connected tablet is only needed once, for the initial setup.proceq GS8000 Pro Subsurface Mapping - Fig
14

h. The user should refer to appropriate textbooks on the subject of ultrasonic testing and thickness gauging for more information. It is important that you understand and observe this information to avoidany operator errors that might lead to false test results. Such false results could result in personal injuries or asset damage.
This instrument is to be used only for testing materials in an industrial environment. Any use for medical applications or any other purpose is not permitted.proceq GS8000 Pro Subsurface Mapping - Fig
15 i. The cable connectors to be plugged in to the UT8000 device must be of type Lemo00.
To avoid the risk of electric shock, do not touch the inner conductor of the Lemo00 connectors. Up to 400 V can be present on the inner conductor .
j. The IP67 protection will be permanently lost if the Wi-Fi connector seal is broken open
k. Always use equipment and accessories that meet Proceq specifications. Using incompatible, broken or poor-quality equipment could cause malfunction and/or damage, or human injury.proceq GS8000 Pro Subsurface Mapping - Fig
16

l . Verify that the base unit is securely attached on the belt holder or tablet holder.
m. Proceq makes no claims regarding the strength of the magnets and is not responsible for damaged equipmentproceq GS8000 Pro Subsurface Mapping - Fig
17Scanning the QR code with an Internet connected tablet is only needed once, for the initial setup.
UK Declaration of Conformity
Products…………… Proceq UT8000 Flaw Detector
Proceq Part Numbers……….. 7931×500
Manufacturer………………. Procegq SA, Ringstrasse 2 8603 Schwerzenbach, Switzerland
The object of the declaration described above is in conformity with relevant statutory tequirements and designated standards:
Electrical Equipment (Safety) Regulations 2016 /…………S.1. 2016:1101
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements EN 61010-1:2010
Radio Equipment Regulations 2017 SA. 2017:1206
Wideband transmission EN ETS! 300 328 V2.2.2
Ground- and Wall- Probing Radar applications EN 302 066 V2.1.1
ElectroMagnetic Compatibility (EMC) standard for radio equipment EN ETSI 301 489-17 and services V3.2.0
The Batteries and Accumulators (Placing on the Market) S.1. 2008:2164
Regulations 2008
The Restriction of the Use of Certain Hazardous Substances in $.1. 2012; 2032
Electrical and Electronic Equipment Regulations 2012
Technical documentation for the assessment of electrical and  electronic products with respect to the restriction of hazardous substances EN 50581:2012

Schwerzenbach, 01.0kt.2022

Patrick Waller
Declaration of Conformity
Products Proceq UT8000 Flaw Detector
Proceq Part Numbers 7931×500
Manufacturer Proceg SA, Ringstrasse 2 8603 Schwerzenbach, Switzerland
We confirm that the product named above is in conformity with RoHS, WEEE and the following directives and standards:
Low voltage directive 2014/35/EU
Safety requirernents, General requirements EN 61010-1:2015 / IEC 61010- 1:2010
Radio Equipment directive 2014/53/EU
Wideband transmission EN ETSI 300 328 V2.22
Ground: and Wall- Probing Radar applications EN 302 066 V2.1.1
EMC Part 17: standard for radio equipment and services EN ETS! 301 489-17 V3.2.0
Battery directive 2006/66/EC
RoHS directive 2011/65/EU & 2015/863/EU
Assessment of electrical and electronic products with respect to EN IEC 63000-2018
RoHS
Fcc CFR47 Part 15
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Industry Canada RSS standards. To comply with FCC and Industry Canada RF radiation exposure limits for general population, the transmitter with its antenna must be installed such that a minimum separation distance of 20 cm is always maintained between the radiator (antenna) and all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.
Schwerzenbach, 31.Jul.2022

Patrick Waller

Swiss Made Declaration
Product: Proceq UT8000
Proceq Part Numbers: 793 10 500
Manufacturer: Proceq SA
Ringstrasse 2, 8603 Schwerzenbach, Switzerland
We confirm that the products named above were developed and manufactured in Switzerland and fulfill the requirements needed for the declaration “Made in Switzerland” or “Swiss Made”.
The requirements for industrial products are specified in detail in the National Swiss Trademark Protection Statute (Art. 47-50, MSchG) covering goods and services.
Schwerzenbach, 20.05.2019
Patrick Waller
Chief Operating Officer
Notice
This document (incl. Quick Start Guide and Product Certificates) constitutes an integral part of Proceq’s General Terms and Conditions of Sale and General Terms and Conditions of Rental, together with any other guideline, precautions, policies and conditions which Proceq has made and may make available to you at www.proceg.com/downloads, as amended from time to time (the Documents). Proceq reserves the right to change without notice any information, specifications and recommendations contained in this document and in any of the associated Documents.
You shall observe and be solely responsible for the safe and lawful use of and your own conduct while using this product, and any consequences thereof. The use and operation of this product is at your own discretion and risk. Proceq hereby disclaims any and all loss, liability or damages resulting from or out of your use of the product. Please ensure you operate and use this product only for purposes that are proper and in accordance with the instructions given herein together with all safety and health precautions, applicable laws, tules, regulations, and as provided for in any of the Documents.

The English version of the content remains the official version.
All translated content should bear an appropriate notice to this effect.
v.1.1
For safety and liability information, please check www.screeningeagle.com /safety-and-liability
Subject to change. Copyright © Proceq SA. All rights reserved.

ASIA-PACIFIC
Screening Eagle Singapore Pte. Ltd.
1 Fusionopolis Way
Connexis South Tower #20-03
Singapore 138632
T +65 6331 4151| EUROPE
Screening Eagle Technologies AG
Ringstrasse 2
8603 Schwerzenbach, Zurich
Switzerland
T +41 43 355 38 00| USA, CANADA & CENTRAL AMERICA
Screening Eagle USA Inc.
4001 West Parmer Lane
Suite 125
Austin, TX 78727
United States
T +1 724 512 0330
---|---|---
CHINA
Proceq Trading Shanghai Co. Ltd.
Part of Screening Eagle
Room 701, 7th Floor, Golden Block
407-1 Yishan Road, Xuhui District
200030 Shanghai
China
T +86 21 6317 7479| UK
Screening Eagle UK Limited
The Bradfield Centre
184 Cambridge Science Park Road
CB4 0GA, Cambridge
United Kingdom
T +44 1223 981905| Screening Eagle USA Inc.
117 Corporation Drive
Aliquippa, PA 15001
United States
T +1 724 512 0330
| MIDDLE EAST AND AFRICA
Proceq Middle East and Africa
Part of Screening Eagle
Sharjah Airport International
Free Zone, P.O.Box: 8365
United Arab Emirates
T +971 6 5578505| SOUTH AMERICA
Proceq SAO Equipamentos de
Mediçao Ltda.
Part of Screening Eagle
Rua Paes Leme, 136, cj 610
Pinheiros, Sao Paulo
SP 05424-010
Brasil
T +55 11 3083 3889

82079301 | 11.2019
ScreeningEagle.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals