Brennenstuhl MULTI 6050 MH Mobiler LED Hybrid Strahler
SAFETY INSTRUCTIONS
- Always check the product for damage before use. Never use the product in case of any damage. In case you find the product to be damaged, please refer to an electrician or the manufacturer’s service address.
- Do not use the product in potentially explosive atmospheres – danger of death!
- Keep the floodlight away from children. Children are not aware of the risks posed by electric current.
- For operating the floodlight, only use original rechargeable batteries of the following manufacturers: Bosch, Dewalt, Makita, Metabo (CAS), Milwaukee. Use of other rechargeable batteries may cause damage. Only use the supplied connection cable to operate the hybrid function.
- Please never look directly into the light.
- A destroyed protective cover cannot be replaced. The floodlight has to be disposed of.
- The outer flexible line of this lamp may be exchanged and is available as accessory.
- The product is not IP65-compliant (dust-protected and protected against splashing water)
- with removed battery protective cover. The protective cover can only be used up to and including ProCORE 18 V 8.0 Ah. Without closed protective cover IP20.
TECHNICAL DATA
- Protection class: II
- IP class/shock resistance: IP65, IK08
- Temperature range: -10 °C to +40 °C
- Connection cable: H07RN-F 2×1,0
- Mains plug MULTI 6050 MH: Schuko
- Mains plug MULTI 6052 MH: CH
Types: | MULTI 6050 MH / MULTI 6052 MH |
---|---|
Compatible battery types: | Bosch Professional batteries 18 V/2-12 Ah |
Dewalt, Makita, Metabo (CAS), Milwaukee (18 V rechargeable batteries)
Nominal voltage:| 100-240 V~ 50/60 Hz
Power consumption:| 60 W
Max. current:| 0.8 A
Power factor:| > 0.9
Max. projected area:| 684 cm2
Dimensions:| 25.6x16x27.5 cm
Dimensions of protective cover:| 6.8×10 cm
Weight:| 3.25 kg
This product is suitable for indoor and outdoor lighting purposes.
COMMISSIONING
Place the floodlight on a dry and level surface. The adjustable bracket can be
used to set various inclinations for the floodlight.
INSERTING AND REMOVING THE BATTERY
The floodlight is intended for operation with the subsequently listed
batteries: brennenstuhl® professional line battery AB 1805
Bosch battery GBA 18 V x.x Ah Professional
Bosch ProCORE 18 V (up to a max. of 12 Ah) Professional
Dewalt 18 Volt rechargeable batteries
Makita 18 Volt rechargeable batteries
Metabo (CAS) 18 Volt rechargeable batteries
Milwaukee 18 Volt rechargeable batteries
The adapter can be inserted easily and quickly. To do so, open the lock (Fig. 1a) and fold the battery cover to the side (Fig. 1a). Now insert the suitable adapter (Fig. 1c) into the Brennenstuhl interface (Fig. 1b) and lock it using the red locking mechanism (Fig. 1d). Insert the charged 18 Volt rechargeable battery into the battery holder from the side (Fig. 1e) until it noticeably engages in the end position. To remove the rechargeable battery, press the battery unlocking button and pull the rechargeable battery out of the battery holder to the side. Afterward, close the cover again (Fig. 1f). To ensure IP65 (dust-protected and protected against splashing water), the floodlight may only be operated with correctly closed battery cover. If the device is not used for a longer period of time, remove the rechargeable battery.
The floodlight can also be operated without battery cover up to 12 Ah rechargeable batteries; in this case, the IP class will, however, be reduced to IP20 and the floodlight may only be operated in a dry environment. To do so, open the battery cover locking (Fig. 1f). Afterwards, remove the battery cover.
OPERATION OF THE HYBRID MAINS FLOODLIGHT WITH RECHARGEABLE BATTERY
To switch the floodlight on, press the button at the back (Fig. 2). Press the switch multiple times (Fig. 2) to set the brightness to 100%, then 75%, 50%, then 25% and then “off”. Keep the button pressed (Fig. 2) to continuously reduce or increase the brightness. The lower the brightness selected, the longer the floodlight will burn. If the switch is left in any of its “on” positions for longer than 5 seconds, then pressing it once again will always turn it off. If the rechargeable battery is almost flat and the connection cable is not connected, the LED floodlight will flash 5 times. Afterwards, the floodlight remains on for approx. 10 minutes with 50% brightness before it is switched off by the deep discharge protection function. If the connection cable is connected while the floodlight is switched on (Fig. 3), the floodlight will flash 3 times and then automatically switch into mains operation with 100% light.
OPERATION OF THE HYBRID FLOODLIGHT WITH POWER SUPPLY
The floodlight can be connected to the power supply using the supplied plug-in cable via the connection socket at the back side (Fig. 3). To switch the floodlight on, operate the button on the back (Fig. 2). Press the switch multiple times (Fig. 2) to set the brightness to 100%, then 75%, 50%, then 25% and then “off”. Keep the button pressed (Fig. 2) to continuously reduce or increase the brightness. If the switch is left in any of its “on” positions for longer than 5 seconds, then pressing it once again will always turn it off. If the floodlight is connected to the mains, the rechargeable battery is not charged. If the floodlight is connected to the power supply, the floodlight is operated with mains voltage by default. In case of power failure or if the device is unplugged from the mains, the floodlight will automatically switch to battery operation if a rechargeable battery with sufficient charging is inserted into the battery holder. This is signalled by the floodlight flashing three times.
CHARGING THE RECHARGEABLE BATTERY
Only use one of the manufacturer’s original charging device: Bosch, Dewalt, Makita, Metabo (CAS), Milwaukee.
TRIPOD MOUNTING
By means of the holes in the holding bracket, the floodlight can be mounted on a Brennenstuhl tripod.
SCOPE OF DELIVERY
Floodlight, plug-in connection cable, 4 multi adapters: Bosch, Makita, Metabo, Milwaukee/Dewalt, bag.
ACCESSORIES
Suitable accessories are available on our homepage www.brennenstuhl.com.
CLEANING
Before cleaning, disconnect the product from the power supply.
Do not use solvents, caustic cleaning agents or similar products.
Only use a dry or slightly moistened cloth for cleaning.
MAINTENANCE
ATTENTION: The LED lamp does not contain components that require
maintenance. The light source of this lamp cannot be replaced. If the light
source has reached the end of its service life, the entire lamp has to be
replaced. The lamp may not be opened.
Dispose of electric appliances in an environmentally friendly manner! Electric
appliances must not be disposed of in household waste! The European Directive
2012/19/EU on Waste Electrical and Electronic Equipment rules that used
electric appliances should be collected separately and recycled in an
environmentally friendly manner. For possibilities of disposal of the used
appliance, please contact your local or municipal administration.
MANUFACTURER
Hugo Brennenstuhl GmbH & Co. KG
Seestraße 1-3 · D-72074 Tübingen
H. Brennenstuhl S.A.S.
4 rue de Bruxelles ∙ F-6717 Bernolsheim
lectra technik ag
Blegistrasse 13 · 6340 Baar
For more information, we recommend the Service/FAQs section on our homepage
www.brennenstuhl.com.
References
- The domain name luce.se is for sale | Dan.com
- brennenstuhl® | Licht- und Stromverteilung
- brennenstuhl® | Licht- und Stromverteilung
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>