Product Information:
- Product Name: CTBRCB03JM03-PC Lighting Controller
- Output Wattage: 600W Max
- Universal Voltage: 120-277VAC
- Dimming Controller Type: 0-10Vdc Type / Channels
- RF Communication Type: 1/2 Knockout Mount IP66
- Input Surge Protection: Yes
- Overall Size: Not specified
- Weight: 15 lbs
- Sound Rating: Not specified
- Service Life: Not specified
- Warranty: Not specified
Product Usage Instructions:
- Step 1: Check the input voltage and frequency. The input voltage should be in the range of 120-277VAC with a frequency of 50-60Hz.
- Step 2: Connect the input wires to the power source. The input current should not exceed 5A.
- Step 3: Connect the output wires to the luminaire. The maximum load should not exceed 600W.
- Step 4: Install the lighting controller using the mounting type suitable for your application.
- Step 5: Connect the dimming controller and RF communication type according to your requirements.
- Step 6: Ensure input surge protection is in place.
- Step 7: Turn on the power source and operate the device as per your requirements.
Note: Always refer to the product manual for detailed instructions and safety precautions before using the device.
Lighting Controller
- Output Wattage: 600W Max.
- Universal Voltage (120-277VAC)
- 0-10V Luminaire
- 1/2” Knockout Mount
- IP66
- FCC ID : 2AJ9LCTRCB0XJM0XXXX
General Specifications
Fulham’s EliteBlue commissioning app can be found on the Apple app store by
searching “EliteBlue”. For web app, please visit
https://eliteblue.fulham.com
Complete commissioning manual can be found at:
https://www.fulham.com/PDFs/eliteBlue-commissioning-manual.pdf
Power Metering Accuracy
Category| Parameters| Unit (range)| Resolu on/ Accuracy Devia on (%)| Data
erasable
---|---|---|---|---
Power Metering- Grid Side
| Maximum AC Mains Voltage| V (108-305V)| 2%| Y
AC Mains Voltage| V (108-305V)| 2%| /
AC Mains Current| mA (80-5000) mA| 2%| /
Frequency| Hz (50 – 60)| 2%| /
Power Factor| (0 – 1) step 0.01| 2%| /
Input Power| W (10-600)| 2%| /
Apparent Power| W (10-600)| 4%| /
Lifetime Input Energy| Wh (0 – 429496729.3)| 2%| N
Resettable Energy| Wh (0 – 429496729.3)| 2%| Y
Lifetime Apparent Energy| Wh (0 – 429496729.3)| 4%| N
Resettable Apparent Energy| Wh (0 – 429496729.3)| 4%| Y
Average Mains Voltage| V (0-310)| 2%| Y
Average Mains Current (mA)| mA (0 – 15000)| 2%| Y
Average Frequency| Hz (0 – 60)| 2%| Y
Diagnos c – Bridge
| Bridge Operating Time| hrs (0 – 1193046)| 4%| N
Bridge Load On/Off Cycle| Counter (0 – 16777213)| 4%| N
Bridge Temperature| °C (0°C – +90°C)| 5%| /
Bridge Temperature w/Hours| °C (0°C – +90°C)| 5%| N
Mechanical Data
Mount screw: #10-24*1 inch
Mounting hole for threaded pipe: 7/8” (22mm)
Notes:
- Driver has two (2) mounting tabs with a round hole in each.
-
Fasten a screw through the mounting tab if mounted on a flat surface.
Overall DimensionsLength| 5.17” [131.5mm]
Width| 2.26 ” [57.6 mm]
Height| 1.29 ”
[33mm]
Wire Length
AC Input (White/Black)| 12.4” [315mm]
LED Output
(Red/Black)
| 12.4” [315mm]
Control 0-10V (Pink/Purple/ Orange)| 12.4” [315 mm]
RJ12
| 17.3” [440 mm]
Ground (Green/Yelow)
| 12.4” [315 mm]
Wiring Diagram
Color Tuning Wiring
Non Color Tuning Wiring
Notes:
Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-rated
construction.
FCC Caution
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received,including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Restoring Factory Settings
- To reset the unit you will need to place and hold a magnet for 10 seconds on the reset icon on the location of the unit shown in the image below.
- Once the magnet has been placed the Indicator Light will stay lit and begin to flash until it shuts off indicating that the unit has been successfully reset.
- Remove the magnet from the unit, the Indicator Light will light up and flash repeatedly
- The unit is now ready to be provisioned.
SPECIFICATION INSTRUCTIONS
Part Number Matrix
Product Image: LED Driver
Packaging
Master Carton
OUTER DIMENSION
L| W| H
18.26”(464mm)| 14.33”(364mm)| 7.48”(190mm)
Net
Weight
| Gross
Weight
| QUANTITY
23.14 lbs. (10.5kg)| 24.69lbs. (11.2 kg)| 30pcs.
Fulham co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.:
1-323-779-2980 Fax.:
1-323-754-9060.
order@fulham.com
www.fulham.com
Specifications subject to change without notice.
References
- Fulham: Lighting Solutions | LED Drivers | Ballasts | Emergency | Modules
- Fulham: Patents
- Fulham EliteBlue Commissioning
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>