SloanLED 701269-RGB3M1-MB Spectrum RGB/RGBW Module Installation Guide

June 5, 2024
SloanLED

SloanLED Spectrum RGB/RGBW Module
Installation Guide for 701269-RGB3M1-MB and 701269-RGBW3M1-MB
Installation Guide

701269-RGB3M1-MB Spectrum RGB/RGBW Module

WARNING: Risk of electrical shock. New installation and LED Retrofit Kit installation to require knowledge of sign electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. Follow all NEC and local codes. SloanLED Spectrum RGB/RGBW The module is not suitable for submersion or direct exposure to water for extended periods of time.
For New Installation, proceed with Step 1 below. For Retrofit Installations, begin with Retrofit Instructions on page 2.

New Installation

  1. Tools required: Measuring tape, wire strippers. Optional: Drill, screwdriver.SloanLED 701269 RGB3M1 MB Spectrum RGB RGBW Module - NOTE: Modules must be mounted in an enclosed sign. This
    product is not suitable for immersion or direct exposure to water for extended periods of time.

  2. Components list:
    • SloanLED Spectrum RGB/RGBW Module, model numbers 701269-RGB3M1-MB or 701269-RGBW3M1-MB
    • SloanLED 12 V Class 2 output power supply (refer to “SloanLED Power Supply Guide for Sign Products” for appropriate 12 V power supply models)
    • UL approved 18 AWG or larger diameter supply wire
    • UL-approved wire connectors appropriate for wire gauge used
    • UL approved 5-conductor cable
    • Optional for mounting: Electrical grade silicone, #6 (M3) sheet metal screws, or 1/8″ (3 mm) aluminum rivets
    • 12 V 4-channel RGBW LED controllerSloanLED 701269 RGB3M1 MB Spectrum RGB
RGBW Module - 1

  3. Layout: To populate the sign, refer to SloanLED Spectrum RGB and RGBW Module density guidelines as well as the power supply loading chart below to determine the appropriate number of modules and power supplies.

  4. Peel and stick: Clean the inside sign with rubbing alcohol and allow it to dry. Using a predetermined layout and LED placement from Step 3, remove the tape backing and stick modules into place. Ensure modules are firmly attached.SloanLED 701269 RGB3M1 MB Spectrum RGB RGBW Module - 3

  5. Fasteners: If desired, modules can be secured with #6 (3.5 mm) pan head sheet metal screws.SloanLED 701269 RGB3M1 MB Spectrum RGB RGBW Module - 4

  6. Connections: Modules may be connected in series or parallel.
    NOTE: It is recommended to connect no more than half of the maximum 60 W power supply capacity in series to minimize line loss.SloanLED 701269
RGB3M1 MB Spectrum RGB RGBW Module - 5 WARNING: Connect Yellow wire to 12V+ from the power supply or RGBW controller. Connect Red, Green, Blue, and White wires to DC-, or appropriate terminals of RGBW controller. Reverse polarity connections may damage LEDs and will void the product warranty.

  7. Cap all unused wires:
    The strand of modules should not be looped to create a closed circuit.SloanLED 701269 RGB3M1 MB Spectrum RGB RGBW Module -
6

  8. Connect the power supply to the first module on string: See the power supply install guide for more information regarding power supply installation.SloanLED 701269 RGB3M1 MB Spectrum RGB RGBW Module - 7

Retrofit Instructions for Existing Signs

GENERAL-PURPOSE RETROFIT SIGN CONVERSION.
FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS.
KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY THE INSTRUCTIONS ARE PRESENT.

WARNING: Risk of fire or electric shock. Install this kit only in host signs that have been identified in the installation instructions, and where the input rating of the retrofit kit does not exceed the input rating of the sign. Installation of this LED retrofit kit may involve drilling or punching holes into the structure of the sign. Check for enclosed wiring and components to avoid damage to wiring and electrical parts.

  1. Identify sign to be retrofit and ensure branch circuits supplying existing sign are within voltage range for LED power supply.
    Refer to the components list (page 1) and “12 VDC Power Supply Capacity Chart” (page 3).

  2. Remove existing lighting equipment intended to be replaced, such as neon or fluorescent, and all power supplies, transformers, or ballasts.
    Remove existing neon and all standoffs to leave an empty channel letter can. NOTE: All materials removed must be disposed of in accordance with applicable local, state, and federal laws.

  3. If required by local, state, or national electrical code, install a new disconnect switch.

  4. Determine suitability and structural integrity of existing signs after removal of existing lighting equipment. If retrofit does not require the making of any new holes, do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. If existing holes are present in a wet or outdoor location sign, repair and seal any unused openings in the electrical enclosure. Openings greater than 0.5″ (12.7 mm) diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with nonhardening caulk.

  5. Clean the inside of the sign using a non-oil-based cleaner. Follow all manufacturer’s instructions and ensure the inside of the sign is dry before proceeding with the installation. This is an important step for good adhesion of SloanLED channel letter module mounting tape.

  6. To populate the sign, refer to SloanLED Spectrum RGB and RGBW Module density guidelines as well as the power supply capacity chart to determine an appropriate number of modules and power supplies. A list of acceptable power supply models is shown in the supplemental “SloanLED Power Supply Guide for Sign Products”.

  7. Follow all instructions on page 1 under “New Installation” to properly install LED modules.

  8. Connect modules to power supply output as shown on page 2 under “New Installation”.

  9. Connect power supply input as outlined in the power supply installation guide in accordance with local, state, and national electrical codes by qualified personnel. Refer to the power supply install guide included with the power supply for details.

  10. If required, install a disconnect switch in accordance with local, state, and national electrical codes by qualified personnel.

12 VDC Power Supply Capacity Chart

Maximum feet (meters) / modules

| SloanLED Spectrum RGB Module| SloanLED Spectrum RGBW Module
Power output| RGB
(1.5/ft, 4.9/m)| RGBW
(1.5/ft, 4.9/m)
20 W| 17.3 (5.28) / 26 mods| 12.6 (3.9) / 19 mods
25 W
(EU/ROW ONLY)| 21.3 (6.5) / 32 mods| 16 (4.9) / 24 mods
30 W
(EU/ROW ONLY)| 26.0 (7.93) / 39 mods| 19.3 (5.9) / 29 mods
60 W| 53.3 (16.3)/ 80 mods| 40.0 (12.2)/ 60 mods
2 × 60 W| 2 × 53.3 (16.3)/ 80 mods| 2 × 40.0 (12.2)/ 60 mods
2 × 75 W
(EU/ROW ONLY)| 2 × 64.7 (19.72)/ 97 mods| 2 × 48.7 (14.8)/ 73 mods
Power used per ft (m) in watts| 1.04 W (3.38)| 1.38 W (4.53)

Capacities based on 90% of power supply output.
NOTE: Refer to “SloanLED Power Supply Guide for Sign Products” for appropriate 12 V power supply models.

Scan QR code to download SloanLED Power Supply Guide for Sign Products

SloanLED 701269 RGB3M1 MB Spectrum RGB RGBW Module -
qrhttps://sloanled.com/downloads/SloanLEDPowerSupplyGuideForSignProducts.pdf

Extension of Power Supply Leads
If a longer lead wire from the power supply to LED modules is needed, an extension can be used. The extension should be kept as short as possible, i.e., under 15 ft for 18 AWG UL Listed PLTC (4.6 m for 1 mm² PLTC) or under 50 ft for 14 AWG UL Listed PLTC (15.2 m for 2.5 mm² PLTC).

Troubleshooting

NOTE: A licensed electrician should perform all applicable steps.

The entire sign or leg does not light after complete installation| Check the connection from the power supply lead to the first module. Make sure the polarity of connections made at the power supply lead and any jumper wire is correct.
---|---
Still does not light| Check the output voltage of the power supply using a voltmeter. The output voltage should be DC 12.0 V ± 0.5 V. If there is no output voltage, have a licensed electrician check the input voltage. Make sure the power supply is connected correctly and getting primary power. If the power supply is connected properly and getting primary power and there is still no output voltage, try a different power supply.
Still does not light| If the power supply is getting primary power and the modules don’t light, there may be a short in the secondary wiring. Check all connections and cap all loose wires.
The beginning of a leg lights, but the entire leg does not light or lights intermittently| The primary cause of a portion of a SloanLED Spectrum RGB/RGBW Module leg not lighting or lighting intermittently is a bad connection or reverse polarity connection between the modules that light and the modules that don’t light. Check this connection.

SloanLED 701269 RGB3M1 MB Spectrum RGB RGBW Module - 8Customer service and technical support
SloanLED Headquarters
5725 Olivas Park Drive, Ventura, CA, USA
888.747.4LED (888.747.4533) • info@SloanLED.com
SloanLED.com
P/N 402892 Rev C 2022-03-21
SloanLED Europe b.v.
Argonstraat 110, 2718 SN Zoetermeer, NL
+31 88 12 44 900 • Europe@SloanLED.com

SloanLED logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals