Laptop Direct 210860 Solar Inversion Power Supply System User Manual
- June 12, 2024
- Laptop Direct
Table of Contents
Laptop Direct 210860 Solar Inversion Power Supply System User Manual
Dear consumer
Thank you very much for choosing our products! Before using this product, please read this manual carefully, including installation, use and troubleshooting and important information and advice. Please properly keep this manual!
Product Features
- Excellent performance because of double CPU intelligent control technology;
- A wide range of applicable loads because of pure sine wave AC output
- The mains supply mode /battery mode can be set for flexible
- Convenient and practical 5VDC-USB output port and 12VDC output port;
- Digital LCD and LEDs for visualization of operation status of the equipment
- Overcharge protection and over discharge protection for a longer battery life;;
- Safe and reliable with intelligent exhaust fan control
- Overall automatic protection and alarms including AC output overload protection . short circuit protection . etc
Installation and Storage instructions
Unpacking inspection
- Open the package, check whether the product accessories is complete, including: a host controller, a user manual
- Check whether the device is damaged in transit, if you find damaged, please do not start machine and inform your shipper and dealer.
Installation and Storage matters need attention
-
Install equipment should be operated by a professional personal, or
performed by the local distributor. -
During transportation, it need taking appropriate protective measures. When the equipment is moved to high temperature environment from low temperature environment may appear water, in order to ensure safety so it must be completely dry before use.
-
Do not expose the device to damp, flammable and explosive, dust mass and harsh environments; Do not cover and blocking the air vents, so that having good heat dissipation;
-
Battery switch on backboard should be under off state when the machine is not be used for a long time.
Product appearance diagram and introduction
Front panel diagram
Backboard diagram introduction
Introduction:
- Fan:
- AC Output (Max. 10A)
- AC Input holder:
- AC Input
Solar energy charge/discharge LED indicator state introduction
LED display | Introduction |
---|---|
Solar | Green |
Twinkle | Charging controller to prepare… |
Extinguish | Charge controller is in standby… |
Battery | Green/Redtwotone |
reminder;
Green quickflashing| Battery voltage charge protection;
Green light| Battery voltage normal
Orange(Red+green light)| Battery voltage low voltage reminder;
Red light| Battery voltage under-voltage protectionreminder;
DCOutput| Yellow| Quickflashing| DC load current overload or short circuit
Light| DC output voltage normal
Twinkle| DC load current overload
Extinguish| Power off DC output
Inverter LCD display/ operation introduction
LCD display and function key operation interface can display the equipment working state, such as: input/output voltage, frequency, the mains supply mode, inversion mode, battery capacity, loads capacity, alarming reminder etc.
Alarm warning instruction
Equipment normaloperation | Buzzingforbid | Default state, no buzzing |
---|---|---|
Buzzingopen | Buzzer alarm 4 time per 15 seconds indicate the equipment under |
batterypack inverter mode.
Battery pack highvoltage alarm| Buzzer alarm 4 times per second, indicate
highvoltage
Battery pack lowvoltage alarm| Buzzer alarm 2 times per second, indicate
lowvoltage
Over temperaturealarm| Buzzer alarm 2 seconds pause| 1 second
Electric generator connection announcements
If connect electric generator, it needs operate as below:
- Start up electric generator and after it running stable, make electricgenerator output power connect into the equipment input terminal, thenmakesure the equipment output is no-load, then start up the equipment.
- After the equipment starting, then connect load one by one
- We suggest electric generator capacity should be 2~3 times of thisequipment
Equipment parameter introduction
LCD
& splay| Function introduction
| AC input voltage parameter
| 8 RACOutput frequency parameter
| AC output voltage parameter
**| Working mode selection
The mains supply preferred
mode| Battery preferred mode
1 U a’| nj u JET
Battery icon introduction**
LCD icon| State| Battery voltage/12V; A (Ins)
| Twinkle| <10.5V; A
| Out| I Open the buzzer
Fault/abnormal icon reminder
| | | Fault/abnormal reminder
Load icon introduction
LCD
display| Function introduction
| Output loads overload reminder
CNIIII LOAD
| | 0%-25%| 25 /0— 50%| 50%-75%| 75% — I 00%
| | | | | |
Working mode icon introduction
LCD display| Function introduction
| The mains supply icon
| AC-DC icon
|
| DC-AC icon
|
Buzzing icon introduction
| Lighten| Prohibit the buzzer
| |
Panel key function/LCD setup introduction
Working mode icon introduction
LCD
display| Function introduction
| The mains supply icon
| AC-DC icon
|
| DC-AC icon
|
Buzzing icon introduction
| Lighten| Prohibit the buzzer
| |
LCD display introduction
Working mode introduction
| Working
mode| Running state
---|---|---
| | Mains supply preferred mode, after the device starts, the grid input under
normal operation, the equipment
| The mains| through the grid bypass regulator to supply power to
| supply|
| preferred
mode| the load, at the same time power battery;When there is having too
high/low/serious distortion of the grid , equipment will make battery energy
through internal module transfer into high quality electricity for load.
| | Battery priority mode, the device for the first time started, the mains
input under normal operation of equipment for mains priority mode, but no
battery power.When the battery in the external charging device (such as solar
charging system) after adequate
| Battery| electricity, equipment automatically converted to
| preferred| battery energy through internal module into high
| mode| quality electricity for load;When the battery power down to low
voltage threshold, the equipment and the mains shunt voltage to supply power
to the load, but no battery power.This pattern is mainly for new energy power
generation system design(such as wind power system)
- Solar:Solar module input terminals
- Battery:External battery input terminals(selectable)
- Battery Switch:built-in battery switch
Front panel introduction
Instructions
- Inverter LCD display / operation interface
- Solar: Solar input state indicator
- Battery: Battery mode indicator
- DC Output: :5VDC-USB、12VDC output indicator
- 5VDC-USB、12VDCoutput ON/OFF switch
- 12VDC Output:12VDCoutput terminal
- 5VDC Output:5VDC-USB output terminal
System connection diagram
Instructions
For external battery pack input switch, please select current of 2P breaker is or above 60A; For solar module input switch, please select current of breaker is or above 30A
Operating instructions
Open/Run
- Check the solar components which has accessed to the equipment terminal voltage and polarity are correct; Such as external expansion of the battery, battery also needs to check its terminal battery end polarity is correct
- Close the built-in battery on backboard breaker“⑦–Battery Switch”,if connect external expansion battery, will also make the circuit breaker connecting in series be closed stat, then the front panel“⑩—Battery”light,“⑪
- DC Output”indicator light state depends on battery voltage/capacity
- Make breaker on solar array connecting in series be closed state, where there is sunshine on solar energy components, the “⑨ – Solar” on the front panel light is lit, the photovoltaic components with built-in controller charge for battery power;
- Long press the button “ON/OFF” for 2 seconds, release after buzzers once,the machine starts AC output, then long press the button “ON/OFF” for 2 seconds, release after buzzer once,the machine close AC output。
Operational considerations:
When start the equipment, please operate breaker as following sequence, first
close the battery circuit breaker, and then close solar module input circuit
breaker; Closing device, first disconnect the solar component input circuit
breaker, and then disconnect the battery circuit breaker;
Using considerations:
When solar module is under disconnection and not be used for long time, it
should be under close state for built-in battery circuit breaker on backboard
:” ⑦-Battery Switch”, it also should be disconnect its anode connection wiring
circuit breaker if it have external battery pack, in order to avoid batter
deep discharge loss( built-in controller has power loss when standby):
Simple fault judgment and processing
Warning: Internal of the machine has high pressure!Don’t openit own,and try to do the repair or maintenance, so as not to risk electric shock
Fault | possible reasons | solution |
---|
When the machine have
enough light
point-blank
photovoltaic modules,
“Solar” indicator light is
not lit| Photovoltaiccomponent cable array
open circuitop| Please check on whether
both ends of the pv ray
wiring is correct, the
contact is reliable or not.
“DC output”indicator
light flash, DC no
output| DC loads overload or
short circuit| Check loads and
connection and restart
equipment
The mains supply from
time to time| Input fuse damaged| Change the same fuse
Machine load time
reduced| Not enough for battery charging| Make sure battery MI of
charge normally
The machine can’t be
started| Machine overload| Removal of critical load
bum-in, and can’t be charged full| Please connect with CSR so that getting
batterychanging module
The mains input line
or the battery cables
poor contact| Check and connect again
Starting up alarm| Battery power is not
enough| Make sure battery MI of
power normally
Overload| Removal of critical load
Buzzer is 2 seconds but
stop I second| Internal over
temperature alarm| Check whether the fan and
cooling hole is blocked
Fan working sometimes
quickly, sometimes
slow| Internal temperature is .higher than 45 degreesturn fast, slow turning
less than 42 degrees|
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>