Assembly Instructions

item no:51110-51112-51113 start here

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly

Drawin g 1 – Shade Assembly HINKLEY 51110 Argo 1 Light 8 Inch Tall
Bathroom Sconce - fig 1 Note: make sure the brackets are installed in the correct orientation in order for the shade to secure properly.

  1. To start assembly secure top of bracket (B) to socket body (1) using screws (5)
  2. Repeat process for all four brackets.
  3. Next slip screw (3) through hole in bottom of bracket and hole in shade (2)
  4. Secure bracket to shade using ball knob (4)
  5. Repeat steps 3 and 4 for all four brackets
  6. Follow mounting instructions on the next page to complete installation

Wall Mounting Instructions

Item No: 51110-51112-51113
start here

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.

Drawing 1 – Mounting strap preperationHINKLEY 51110 Argo 1 Light 8 Inch Tall
Bathroom Sconce - fig 2

  1. Prepare mounting strap (A) by threading two machine screws (B) (provided), into back of gull wing section of mounting strap (A) -see Drawing 1.
    • Be sure the holes into which the screws are threaded match the spacing of holes (D) in the back plate (1) – see Drawings 1 and 2.

  2. Attach mounting strap (A) to junction box (J), (mounted in wall) using two (8-32) screws 1” long (C), NOT PROVIDED – see Drawing 2.

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Drawing 2 – Mounting strap installationHINKLEY 51110 Argo 1 Light 8
Inch Tall Bathroom Sconce - fig 3Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to assembly instructions for the purchased fixture to complete any assembly required.

  1. To attach fixture to the wall slip screws (B), in the mounting strap (A), through holes (D) in backplate (1) – see
    Drawing 2.

  2. Thread on barrel knobs (F) and tighten till canopy is flat against the wall.

  3. Fixture can now be lamped accordingly.

wiring grounding instructions

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
wiring instructions
Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Drawing 1 – Flush Mount Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — – see Drawings 2 or 3.

  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).

  3. Cover open end of connectors with silicone sealant to form a watertight seal.
    If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

  4. Please refer to the grounding instructions below to complete all electrical connections.

Drawing 2 – Chain Hung HINKLEY 51110 Argo 1 Light 8 Inch Tall Bathroom
Sconce - fig 5grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.
Drawing 3 – Post-Mount HINKLEY 51110 Argo 1 Light 8 Inch Tall Bathroom
Sconce - fig 6

Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.

33000 Pin Oak Parkway,
Avon Lake, OH 44012
800.446.5539 / 440.653.5500