AKO-14545 Wizard Digital Table Clock User Guide
- June 5, 2024
- AKO
Table of Contents
AKO-14545 Wizard Digital Table Clock User Guide
1- Warnings
-If the equipment is used without adhering to the manufacturer’s instructions the device safety requirements could be compromised.
-The installation location of the equipment must be protected from vibrations, water and corrosive gases where the ambient temperature does not exceed the value featured in the technical data.
-To ensure a correct reading the probe must be located away from external effects.
-The power circuit should be equipped with a switch for its disconnection of at least 2 A, 230 V, situated near the appliance.
The cables will be fed in from the rear and will be types H05VV-F or H05V-K.
-The section to be used will depend on the local standard in force, 2 however must never be less than 1 mm .
-The wiring cables for the contact relays must have a section of 2.5 2 mm .
-Make the connection before plugging in the terminals to the equipment (See Fig.A).
ATTENTION: The equipment is not compatible with AKO-14917 (external communication module) and AKO-14918 (programming key).
2- Installation
3- Quick start
4- “WIZARD” table
The “WIZARD” table in the appendix is divided into 3 groups of columns. The first describes the different installation types (number of compressors and fans, if they have an inverter, etc.) associated with the INI option. The second group specifies the function assigned to each relay depending on the INI option selected. The third group specifies the function assigned to each digital input depending on the INI option selected.
Installation type
*The meaning of each
function is described in the “WIZARD” appendix
5- Operation
ESC key
In the programming menu, exit the parameter without saving changes, return to
previous level or exit programming.
SET key
By pressing this key for 1 second the probe display units change (according to
parameter C09). Pressing it for 10 seconds accesses the programming menu. In
the programming menu, it accesses the level shown on the display or, during
the setting of a parameter accepts the new value.
▲ UP key
By pressing this key for 1 second probe 2 is displayed for 5 seconds (or probe
1, according to parameter P02). By pressing a second time the probe ambient
temperature value will be shown (only if I07 or I08=3). In the programming
menu it allows scrolling around the different levels, or during the setting of
a parameter, changing its value.
▼ DOWN key
Pressing this key returns the equipment to its normal operation after an alarm
which require a reset (the causes which triggered the alarm must have
disappeared).
In the programming menu it allows scrolling around the different levels, or during the setting of a parameter, changing its value.
6- Operation start-up
Upon being supplied with power the equipment will start up in WIZARD mode (INI / 1 flashing), press ▲ or ▼ to select the most suitable option for the installation type, check the options in the “WIZARD” appendix. The wizard configures the equipment parameters and assigns the input and output functions according to the installation type chosen.
7- Technical specifications
8- Table of parameters and messages
The Def. column indicates the ex-works configured default parameters. The pressure values featured on the table are expressed in bar and those for temperature in ºC. If the wizard meanwhile selects another set of units (parameter C09), the equipment will make the conversion automatically.
AKO ELECTROMECÁNICA , S.A.L. Avda. Roquetes, 30-38 08812 · Sant Pere de Ribes. Barcelona · Spain. www.ako.com
We reserve the right to supply materials that might vary slightly to those described in our Technical Sheets. Updated information is available on our website.
Read User Manual Online (PDF format)