AKO-54041A Emergency Alarm for Lifts Instructions
- May 15, 2024
- AKO
Table of Contents
AKO-54041A Emergency Alarm for Lifts
Product Information
Features
- Provides alarm and emergency lighting in lift cabins during power cuts
- Complies with European standard EN 81-1
- Includes electronic alarm and rechargeable batteries
- Output for emergency lighting lamps (6V, up to 500mA) and a permanent output (6V, up to 40mA)
- AKO-54041A model includes an auxiliary relay for remote device activation
Specifications
- Lamps: 2 dial E10, 6V, 200mA
- Dimensions: 111mm x 77mm x 26mm
Product Usage Instructions
Installation
Refer to the installation diagram for AKO-54041A, AKO-5404C, and AKO-5406 for proper placement and dimensions.
Operation
During a power cut, emergency lighting in the lift cabin will activate automatically. The electronic alarm will continue to operate using its own battery power. When the power is restored,the lighting turns off, and the unit starts recharging automatically.
Maintenance
Regularly clean the equipment surface using a soft cloth, soap, and water. Avoid abrasive detergents, petrol, alcohol, or solvents.
FAQ
- Q: Can the AKO-5404C be installed outside of the lift cabin?
- A: Yes, the AKO-5404C can be installed outside the cabin or at a distance where the alarm signal is required.
- Q: How does the AKO-54041A differ from the AKO-5406 model?
- A: The AKO-54041A includes an auxiliary relay for remote device activation, whereas the AKO-5406 does not have this feature.
Description
The purpose of the AKO-5404C is to provide the cabins of lifts with alarm and
emergency lighting in case of a power cut. They provide sufficient power to
operate the emergency lighting and the powerful electronic alarm, whether or
not there is voltage in the mains supply. This equipment comply with European
standard EN 81-1
Features
The power supply set includes an electronic alarm and recharge automatically
their batteries. It is possible to instal outside of the cabin or at a long
distance where the alarm signal is needed. It has an output to supply 6 V up
to 500 mA to the emergency lighting lamps and a permanent one of 6 V up to 40
mA. The AKO-54041A have and auxiliar relay to act remote devices.
Advertencias
- If the equipment is used without adhering to the manufacturer’s instructions, the device safety requirements could be compromised.
- Always disconnect the power supply to do the wiring. For disconnection, the power supply circuit must be equipped with at least a 2 A,
230 V switch, located near the device and marked as an alarm cut-off device. The cables shall enter through the indicated part and shall be of type H05V-K or H05VVV-F. The 230 V~ connection area must be kept clear of any external elements. The cross-section to be used will depend on the local regulations in force, but must never be less than 1.5 mm2.
Installation
- Secure the alarm unit with 4 screws (A).
- Remove the connection cover (B) by pressing on the sides (C).
- Connect the cables according to the wiring diagram and replace the connection cover (B).
- AKO-5406: Fixing screws max. 4 mm diameter (D).
Remote optional alarm connection
Allowed distance between units: up to 200 m, with 1 mm2 minimum cable
- AKO-54041A
- AKO-5404C
Wiring
Operation
In case of a power cut, the lighting inside the lift cabin comes automatically, the electronic alarm continues in operation due to its own power source from batteries. When the supply is restored, the lighting goes off and the unit begins to recharge automatically.
Maintenance
Clean the surface of the equipment with a soft cloth, soap and water. Do not use abrasive detergents, petrol, alcohol or solvents.
Technical specifications
AKO-54041A / AKO-5404C
-
Power supply.. ……………………………………..230 V~ ± 10%, 50/60 Hz %
-
Maximum input power……. …………………………………3 VA~
-
Nominal current ………………………………………………..17 mA~
-
Relay NO……….. ………………………………………………… 24 V 8 A cos ϕ =1
-
Emergency lighting output………. ……………………………6 V, max. 500 mA
-
Permanent output. ……………………………………………6 V, max. 40 mA
-
Autonomy time…. …………………………………….> 1 hour
-
Sound level… …………………………………………………..> 90 dB from 1 m
-
Batteries. ……………………………………………….. 5 of Ni-Cd, 1,2 V, 0.7 Ah
-
Working ambient temperature ………………………………………… 5 ºC to 40 ºC
-
Storage ambient temperature ……………………………………..-20 ºC to 50 ºC
-
Working relative humidity….. ……………………. < 90 %
-
Overvoltage category…. ……………. II s/ EN 61010-1
-
Installation category… …………….. II s/ EN 61010-1
-
Pollution degree ……………………………….. II s/ EN 61010-1
Dimensions ……………………………..212 mm x 139 mm x 52 mm -
Expected maximum altitude above sea level. ………………….. 2000 m
-
Intended use …………………………………… Indoor
-
Installation…. ………………..Use 3.9 x 32 mm sheet metal screws with 5 dowels.
-
Double isolation between power supply, secondary circuit and relay output.
AKO-5406
- Lamps ………………………………..2 dial E10, 6 V, 200 mA
- Dimensions. …………………..111 mm x 77 mm x 26 mm
Read User Manual Online (PDF format)