luminii BAR-XX Linear Illumination System Instruction Manual
- June 4, 2024
- luminii
Table of Contents
BAR-XX Linear Illumination System
Instruction Manual
Models BAR-XX
Please read all instructions prior to installation and keep them for future reference!
- PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
- USE ONLY WITH A CLASS 2 POWER UNIT.
- 24 VOLTS DC.
- SUITABLE FOR DAMP LOCATIONS.
- SURFACE MOUNT ONLY
- SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPACE.
- INHERENTLY PROTECTED
|
---|---
Bara w/ magnetic mounting| Bara w/ fixed mounting clip or drywall clip
|
Bara w/ 9/16” mounting T-bar clip| Bara w/ 15/16” mounting T-bar clip
*LUMINII RESERVES THE RIGHT TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Magnetic Installation
Note : Prior to installation all 24VDC wires must be present near the
fixture. Refer to the power supply installation instructions for additional
information.
Note : More than one person is recommended for this installation.
1.1 If necessary make any pass-through holes for wire lead/connector to the
surface, depending on the power feed option.
1.2 Clean the surface area thoroughly from any debris. Must be made of steel
or a ferrous metal
1.3 Snap the fixture onto the metal surface. If the necessary fixture can
easily be removed by pulling off the surface and repositioning correctly.
2.1 Follow one of the two options to connect the fixture to the power supply.
Option 1 – Secure female quick connect to male quick connect. Feed male
quick connects wire through the conduit to the power supply.
Option 2- Feed wire whip to the power supply.
3.1 Connect +24 VDC red wire from the fixture to the power supply +24 VDC
red wire with a wire nut.
Connect -24VDC black wire from the fixture to power supply -24VDC black wire
with a wire nut.
Fixed Mounting Clip Installation
Note : Prior to installation all 24VDC wires must be present near the
fixture. Refer to the power supply installation instructions for additional
information.
Note : More than one person is recommended for this installation.
|
---|---
1.1 Determine the location of where the fixture(s) will be installed. Lay the
fixture(s) on the surface, and make any necessary reference marks for the
fixed mounting clips. Make marks 4” from each end of the fixture(s) and also
every 30” in between.| 1.2 Drill holes using a 0.180” Ø drill bit.
| |
1.3 Insert plastic drywall anchors, hammering flush
to the drywall surface.| 1.4 Place bracket over drywall anchor and fasten to
drywall using a #4 SS screw, .075” long.| 1.5 Clip on the light fixtures
.1 Align the light fixture to one side of the clips and make sure the fixture
is held.
.2 Snap on the other side.
2.1 Follow one of the two options to connect the fixture to the power supply.
Option 1 – Secure female quick connect to male quick connect. Feed male
quick connects wire through the conduit to the power supply.
Option 2 – Feed wire whip to the power supply.
3.1 Connect +24 VDC red wire from the fixture to the power supply +24 VDC red
wire with a wire nut.
Connect -24VDC black wire from the fixture to the power supply -24VDC black
wire with a wire nut.
T-Bar Clip Installation
Note : Prior to installation all 24VDC wires must be present near the
fixture. Refer to the power supply installation instructions for additional
information.
Note : More than one person is recommended for this installation.
1.1 Prior to installing the fixture on the grid, reference the back of the
fixture to take into consideration end caps & power feed. In addition, take
into account the lead wires they are slightly off-centered.
1.2 Then align & rotate to secure each t-bar clip to the track. Install a
t-bar clip 4″ from each end of the fixture and also one every 30″ in between
the fixture.
1.3 Clip on the light fixtures
1. Align the light fixture to one side of the clips, and make sure the
fixture is held.
2. Snap on the other side.
2.1 Follow one of the two options to connect the fixture to the power supply.
Option 1 – Secure female quick connect to male quick connect. Feed male
quick connects wire through the conduit to the power supply.
Option 2 – Feed wire whip to the power supply.
3.1 Connect +24 VDC red wire from the fixture to the power supply +24 VDC red
wire with a wire nut.
Connect -24VDC black wire from the fixture to the power supply -24VDC black
wire with a wire nut.
Drywall Installation
Note : Prior to installation all 24VDC wires must be present near the
fixture. Refer to the power supply installation instructions for additional
information.
Note : More than one person is recommended for this installation.
1.1 Determine the location of where the fixture(s) will be installed. Lay the
fixture(s) on the surface, and make any necessary reference marks for the fixed
mounting clips. Make marks 4″ from each end of the fixture(s) and also every
30″ in between.
1.2 Lay the fixed clip onto the reference mark points. Drill a 3/16” hole and
insert the drywall anchor. Lay down the clips and secure with the screw.
1.3 Clip on the light fixtures
1. Align the light fixture to one side of the clips, and make sure the
fixture is held.
2. Snap on the other side.
2.1 Follow one of the two options to connect the fixture to the power supply.
Option 1 – Secure female quick connect to male quick connect. Feed male
quick connects wire through the conduit to the power supply.
Option 2 – Feed wire whip to the power supply.
3.1 Connect +24 VDC red wire from the fixture to the power supply +24 VDC red
wire with a wire nut.
Connect -24VDC black wire from the fixture to the power supply -24VDC black
wire with a wire nut.
power supplies at the end of the run
power supplies in the middle of the run
consecutive layout, NOT RECOMMENDED
REV0.3
08102022
PLENUM FOR **SUCH USE IN
ACCORDANCE
WITH UL2043**
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
info@luminii.com
www.luminii.com
Documents / Resources
|
luminii BAR-XX Linear Illumination
System
[pdf] Instruction Manual
BAR-XX, Linear Illumination System, BAR-XX Linear Illumination System,
Illumination System
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>