HYUNDAI HUM 282 Air Humidifier Instruction Manual
- June 5, 2024
- HYUNDAI
Table of Contents
HUM 282 INSTRUCTION MANUAL
Dear customer, thank you for purchasing our product. Please read the operating instructions carefully before putting the appliance into operation and keep these instructions including the warranty, the receipt, and, if possible, the box with the internal packing.
GENERAL SAfETy INSTRUCTIONS
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Before replacing accessories or accessible parts, which move during operation, before assembly and disassembly, before cleaning or maintenance, turn off the appliance and disconnect it from the mains by pulling the power cord from the power socket!
- Do not leave the appliance plugged in power supply without supervision!
- If the power cord of the appliance is corrupted, it has to be replaced by the manufacturer, its service technician or a similarly qualified person so as to prevent dangerous situations.
- Never use the appliance if its power cord or plug is damaged, if it does not work properly if it fell down and was damaged and it is leaking. In this case, take the appliance to a special service to check its safety and proper function.
- The appliance is designed exclusively for private use and for envisaged purposes. This appliance is not fit for commercial use.
- Keep it away from sources of heat, direct sunlight, humidity (never dip it into any liquid), and sharp edges. Do not use the appliance with wet hands. If the appliance is humid or wet, unplug it immediately. Do not put it in water.
- When cleaning or putting it away, switch off the appliance and always pull out the plug from the socket (pull on the plug, not the cable) if the appliance is not being used and remove the attached accessories.
- Do not operate the machine without supervision. If you should leave the workplace, always switch the machine off or remove the plug from the socket (pull the plug itself, not the lead).
- Check the appliance and the cable for damage on a regular basis. Do not use the appliance if it is damaged.
- Pay careful attention to the following “Special Safety Instructions for this unit“.
SPECIAL SAfETy INSTRUCTIONS fOR THIS UNIT
- Operate the appliance only in accordance with the specifications on the rating plate.
- Do not attempt to refill the humidifier without first unplugging the unit from it‘s electrical outlet. Be sure to pull by the plug and not the cord.
- NEVER drop or insert any object into any openings. DO NOT place hands, face, or body directly over or near Moisture Outlet while the unit is in operation. DO NOT cover Moisture Outlet or place anything over it while the unit is operating.
- Always place the humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended under the humidifier. NEVER place it on a surface that may become damaged by exposure to water and moisture (i.e. finished floor).
- DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage, particularly to wallpaper.
- NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit.
- NEVER use detergents, petrol, glass cleaner, furniture polish, paint thinner, or other household solvents to clean any part of the humidifier.
- Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF
- Don’t add into the water any additives that is not produced or supervised by the supplier.
- Keep the cleaning agents away from children.
- Any alternations or refit of the humidifier without specific authorization of the supplier may cause inconveniences or harms to users.
- Turn off the humidifier and pull out the power plug in case of any abnormal sounds or smells during the operation.
- Keep cleaning agents away from your mouth and eyes. If your mouth and eyes come into contact with the cleaning agents by accident, please wash with tap water immediately, or an immediate medical check-up is required in case the circumstance is serious.
- Turn off the machine and pull out the power plug before cleaning, refilling or moving the machine.
- Don’t touch the water in the water basin or any components in the water with any parts of your body when the humidifier is working.
- Don’t turn on the humidifier when there is no water in the water basin.
- Don’t scrape the transducer with hard objects.
- Prevent the water from flowing or spilling into the interiors of the base to avoid any damage to the components.
- Don‘t use the humidifier in high-humidity environments such as bathrooms etc.
- Don’t put the humidifier on the floor being made of wood or bamboo and also similar materials.
- Do not add any Additives such as bath salt or bath oil into the water.
- Place the unit on a flat surface and keep the machine at least 2 meters far away from the furniture and the other electrical appliances.
DESCRIPTION Of THE CONTROLS
P1 Power switch (ON/OFF)
P2 Watter tank
P3 Low water indicator (red), power light (green)
P4 Moisture outlet
P5 Base
P6 Control knob of the setting of mist
INSTRUCTIONS fOR USE
OPERATION PRINCIPLE
Ultrasonic humidifiers atomize the water into ultramarine of about 1-5um using
the ultrasonic high-frequency oscillation principle and diffuse the water mist
into the air by means of the pneumatic device to uniformly humidify the air.
As a proven technology, ultrasonic technology has been widely used in various
fields.
FEATURES AND FUNCTION
- Automatic lack-water security protection: The water level protection switch will stop the transducer from atomizing when the water level in the water basin is below the pre-calculated level to protect the transducer from being burned down, while the power light is still on, with the blower fan keeps working.
- Mist volume is adjustable to make you comfortable.
- Transparent water tank to ensure the water level is visible.
- High efficiency in humidification with large output.
- Low energy consumption, saves 85-90 percent of the electricity of a normal stream humidifier.
- Long lifetime
IDEAL HUMIDITy LEVEL
Relative humidity refers to the ratio of the water content to the saturated
vapor content in the air under a specific temperature and in a specific space.
It is generally marked as %RH, such as 45%RH. Air always contains water vapor
and its percentage varies with the temperature. The higher the temperature is,
the more water vapor is absorbed by the air. That is why we use the concept of
relative humidity. In winter, when the outdoor cold air enters the room, it
will be heated up to a temperature adaptable to the indoor air, and the
relative humidity will drop at the same time. In order to maintain a healthy
interior ambient humidity, adding the water or water vapor into the air
artificially is required—that is air humidification.
Ideal Relative Humidity Levels under Various Conditions (for reference only):
- Ideal ambient humidity for people: 45% RH—65% RH
- Ambient humidity is most favorable for disease prevention and treatment: 40% RH—55% RH
- Computer and communication appliances: 45% RH—60% RH
- Furniture and musical instruments: 40% RH—60% RH
- Libraries, art galleries, and museums: 40% RH—60 RH
The function of Ultrasonic Humidifier:
- To increase and to regulate the relative humidity of the room air
- To eliminate electrostatic charges
- To prevent different diseases
- To keep your appearance fit and protect your skin
- To adjust room temperature
OPERATION INSTRUCTION
DIRECTION fOR USE
- This humidifier should be placed under ambient temperature for half an hour before it is put into use for the first time.
- The desired operating environment for this humidifier is: temperature: 5 – 40 °C and relative humidity 80%RH max.
- Use clean water with temperature below 40 °C, purified water is recommended.
- Check the water basin, make sure it is clear.
CONTROL
- When you use the humidifier for the first time, please take it out from the package.
- Spin the cover of the water tank to open it, pour water into it then screw it down.
- Connect the appliance to the electricity supply. Turn on by power switch P1, the power light turns on (green). Set the steam of mist by turning the control knob (P6) to select slight or heavy mist volume.
- When you clean the machine or pour out the water, you should put a container on the outfall, spin the cover to open it and pour the water into the container. When the machine is clean, please screw down the cover again.
TROUBLESHOOTING GUIDE
In case your humidifier does not work properly, please examine your machine before asking for maintenance service.
Fault Symptom | Analysis of causes | Failure Recovery Method |
---|---|---|
Power light on, the air is blown but no mist. | No water in the tank. | Fill the |
water into the tank.
The cover of the water level protection switches is not closed properly.|
Reinstall the cover.
The peculiar smell of mist.| New machine.| Keep the water tank unco- vered in
a cool place for 12 hours.
Dirty Water or water stored in the tank for a long time.| Clean the water tank
and refill
the tank.
The power light on but no blow or no mist.| Water levels are too high in the
tank.| Keep the water in an ordinary level.
Small mist output.| The transducer is dirty.| Clean the transducer.
Dirty water or water stored in the tank for a long time.| Clean the water tank
and refill the water.
Abnormal noises.| Resonance is caused by insufficient water in the water
basin.| Add water into the basin.
Resonate with the surface where the unit is placed.| Place the unit in the
steady surface or ground.
In case the humidifier is still unable to work normally after the above treatment, please contact the supplier or local maintenance center. We will provide you with wholehearted services.
CLEANING AND MAINTENANCE
In case when the water is hard which means the water contains too much calcium and magnesium, they can cause a “white powder” problems and give heavy scales on the surface of the water basin, transducer, and the inner surface of the water tank. Scales on the surface of the transducer will unable the unit works properly.
We recommend:
- Use cold boiled water or distilled water.
- Clean the transducer, water tank, and basin unit every week.
- Change the water in the water tank more often to keep it fresh.
- Make sure to pull out the water from the water tank and dry the water basin before you store the unit unused for a long period of time.
- Clean the whole unit, and make sure that all parts of the unit are dried completely before being unused for a long period of time.
- Do not use the chemical for cleaning.
How to clean the transducer:
- Put 5-10 drops of cleaning abluent on the surface of the transducer, wait for 2-5 minutes;
- Brush out the scale on the surface.
- Rinse the transducer with clean water.
How to clean the basin unit:
- Cleaning the water basin with a soft cloth and the cleaning abluent if there is a scale in it.
- If the scale is covered on the security switch, drop the cleaning abluent on the scale and clean it out with the brush.
- Rinsing the water basin with clean water.
Technical specifications
- Ultrasonic air humidifier
- Operating time for 7 – 22 hours without filling water
- Elegant look
- Very silent
- Adjustable output circulation
- Container volume 2,2 l
- Low consumption
- Tick over protection
- Color: white-blue
- Noise level: < 35 dB
- Power drain: 30W
- Size: 21,5 x 24 x 17,5 cm
- Weight: 0,9 kg
Input in off mode is < 0,50 W.
we reserve the right to change technical specifications.
WARNING: Do not use this product near water, or in wet areas to avoid
fire or injury of electric current. Always turn off the product when you don’t
use it or before a revision.
There aren’t any parts in this appliance that are reparable by consumers.
Always appeal to a qualified authorized service. The product is under
dangerous tension.
Old electrical appliances, used batteries, and accumulators disposal
This symbol appears on the product, on the product accessories or on the
product packing means that the product must not be disposed of as household
waste. When the product/ battery durability is over, please, deliver the
product or battery (if it is enclosed) to the respective collection point,
where the electrical appliances or batteries will be recycled. The places,
where the used electrical appliances are collected, exist in the European
Union and in other European countries as well. By proper disposal of the
product, you can prevent possible negative impacts on the environment and
human health, which might otherwise occur as a consequence of improper
manipulation with the product or battery/ accumulator. Recycling of materials
contributes to the protection of natural resources. Therefore, please, do not
throw the old electrical appliances and batteries/ accumulators in the
household waste. Information, about where it is possible to leave the old
electrical appliances for free, is provided at your local authority, at the
store where you have bought the product. Information, on where you can leave
the batteries and accumulators for free, is provided to you at the store, at
your local authority.
Licensed by Hyundai Corporation, Korea.
Documents / Resources
|
HYUNDAI HUM 282 Air
Humidifier
[pdf] Instruction Manual
HUM 282, Air Humidifier, Humidifier, Air Cleaner, Air Purifier
---|---
References
- Úvod - ECOBAT
- Úvod | ELEKTROWIN, a.s.
- Úvod - Envidom
- Hyundai Electronics– Hyundai CZ
- SEWA - OZV | elektroodpad | batérie | obaly
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>