Features

  • Constant Voltage + Constant Current mode output
  • Plastic housing with Class II design
  • Built-in active PFC function
  • Class 2 power unit
  • Fully encapsulated with IP67 level
  • Typical lifetime>50000 hours
  • 5 years warranty

Applications

LED panel lighting
LED downlight
LED decorative lighting
LED tunnel lighting
Moving sign

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

LPF-40 series is a 40W AC/DCLED driver featuring the dual modes constant voltage and constant current output. LPF-40 operates from 90 305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the hign efficiency up to 90%, with the fanless design, the entire series is able to operate for -40C~ +80’C case temperature under free air convection. The entire series is rated with IP67 ingress protection level and is suitable to work for a variety of applications at dry, damp or wet locations.

Model Encoding

MEAN-WELL-LPF-40-Series-Constant-
Voltage-3

Specifications

MODEL| LPF-40-12| LPF-40-15| LPF-40-20| LPF-40-24| LPF-40-30| LPF-40-36| LPF-40-42| LPF-40-48| LPF-40-54
---|---|---|---|---|---|---|---|---|---





OUTPUT

| DC VOLTAGE| 12V| 15V| 20V| 24V| 30V| 36V| 42V| 48V| 54V
CONSTANT CURRENT REGION Note.2| 7.2 ~12V| 9 ~ 15V| 12 ~ 20V| 14.4 ~ 24V| 18 ~ 30V| 21.6 ~ 36V| 25.2 ~ 42V| 28.8 ~ 48V| 32.4 ~ 54V
RATED CURRENT| 3.34A| 2.67A| 2A| 1.67A| 1.34A| 1.12A| 0.96A| 0.84A| 0.76A
RATED POWER Note.5| 40.08W| 40.08W| 40W| 40.08W| 40.2W| 40.32W| 40.32W| 40.32W| 41.04W
RIPPLE & NOISE (max.) **Note.3| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 250mVp-p| 250mVp-p| 250mVp-p| 350mVp-p
VOLTAGE TOLERANCE Note.4| ±4.0%| ±4.0%| ±4.0%| ±4.0%| ±4.0%| ±4.0%| ±4.0%| ±4.0%| ±4.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±1.5%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME Note.6| 1000ms, 80ms / 115VAC      500ms, 80ms / 230VAC
HOLD UP TIME (Typ.)**| 16ms/230VAC           16ms/115VAC








INPUT

| VOLTAGE RANGE Note.5| 90 ~ 305VAC         127 ~ 431VDC

(Please refer to “STATIC CHARACTERISTIC” section)

FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load

(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)

TOTAL HARMONIC DISTORTION| THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)

(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)

EFFICIENCY (Typ.)| 84%| 85%| 86%| 87%| 88%| 88%| 88.5%| 90%| 90%
AC CURRENT| 0.6A / 115VAC         0.3A / 230VAC         0.25A/277VAC
INRUSH CURRENT(Typ.)| COLD START 50A(twidth=210 μ s measured at 50% Ipeak) at 230VAC ; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC




PROTECTION

| OVER CURRENT| 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 15 ~ 17V| 17.5 ~ 21V| 23 ~ 27V| 28 ~ 35V| 34 ~ 40V| 41 ~ 49V| 46 ~ 54V| 54 ~ 63V| 59 ~ 66V
Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover




ENVIRONMENT

| WORKING TEMP.| Tcase=-40 ~ +80℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+80℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes



SAFETY & EMC

| SAFETY STANDARDS Note.8| UL8750, CSA C22.2 No. 250.0-08, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384,EAC TP TC 004, IP67, J61347-1, J61347-2-13,GB19510.1,GB19510.14 approved ; design refer to UL60950-1
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION **Note.8| Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load≧60%) ; BS EN/EN61000-3-3, GB17743 and GB17625.1,EAC TP TC 020
EMC IMMUNITY**| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Line 2KV), EAC TP TC 020


OTHERS

| MTBF| 3597.9K hrs min.      Telcordia SR-332 (Bellcore) ;  438.9Khrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 162.54332mm (LWH)
PACKING| 0.44Kg; 32pcs/15.08Kg/0.93CUFT
Note:| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 C of ambient temperature.
2. Please refer to “DRIVING METHODS OF LED MODULE”.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire teminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance: includes set up tolerance, line regulation and load regulation.
5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
6. Length of set up time is measured at first cold start. Turning ONOFF the driver may lead to increase of the set up time.
7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
3. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch
without pemanently connected to the mains.
9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly t point (or TMP, per DLC), is about 75C or less.
10. Please refer to the warranty statement on MEAN WELLs website at http://www.meanwell.com
11. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5 C/1000m with fan models for operating altitude higher than 2000m(6500f).
12. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
xProduct Liability Disclaimer: For detailed information please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

MEAN-WELL-LPF-40-Series-Constant-
Voltage-4

DRIVING METHODS OF LED MODULE
This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs. MEAN-WELL-LPF-40-Series-Constant-
Voltage-5

OUTPUT LOAD vs TEMPERATURE 

MEAN-WELL-LPF-40-Series-Constant-
Voltage-6

STATIC CHARACTERISTIC

POWER FACTOR (PF) CHARACTERISTICMEAN-WELL-LPF-40-Series-Constant-
Voltage-7

※De-rating is needed under low input voltage

TOTAL HARMONIC DISTORTION (THD)

48V Model, Tcase at 70℃

EFFICIENCY vs LOAD

LPF-40 series possess superior working efficiency that up to 90% can be reached in field applications

※ 48V Model, Tcase at 70℃MEAN-WELL-LPF-40-Series-Constant-
Voltage-8

LIFE TIME 

MEAN-WELL-LPF-40-Series-Constant-
Voltage-9

MECHANICAL SPECIFICATION

MEAN-WELL-LPF-40-Series-Constant-
Voltage-10

Recommend Mounting DirectionMEAN-WELL-LPF-40-Series-Constant-
Voltage-11

INSTALLATION MANUAL

Please refer to:http://www.meanwell.com/manual.html

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals