CAL-ROYAL ADB-702 Automatic Door Bottoms Installation Guide

June 5, 2024
CAL-ROYAL

ADB-702
Automatic Door Bottom ITEM/FINISH:

ADB-702

LENGTH: 36”
VINYL INSERT
MILL FINISH ALUMINUM

Installation Guidelines:

  1. Cut the ADB (Automatic Door Bottom) according to the required length.
    Make sure to only cut from the side with no plunger.
    For surface application: Cut the ADB approximately 1/32” shorter than the opening of the door. The cut must be beveled 1/8“, see illustration 3.
    For Semi-Mortise application: ADB must be the same length as the door, less than 1/32”.
    Reminder: If the door is fire labeled, mortise preparation must be done by the door manufacturer to ensure compliance with door standards.
    Note: The cut should not be less than 1-1/2” before the set screw. See Illustration 4.

  2. Place the ADB on the push side of the door. Make sure that the bottom of the aluminum is parallel to the surface of the floor. You may use a 1/4” to 3/8” height shim to keep the unit off the floor during installation.

  3. Fasten unit with screws provided. The ideal clearance between the unit and finished floor is 3/8”.

  4. Set the ADB by turning the actuating plunger clockwise or counterclockwise until the rubber seal gasket touches the floor surface.

  5. Lastly, install the endplate on both ends of ADB.

a) Surface Mounted: the plunger contacts the stop.See illustration #1.

b) Semi-Mortised: the plunger contacts the rabbet. See illustration #2.

ILLUSTRATION 1

CAL ROYAL ADB-702 Automatic Door Bottoms - Figure
6 ILLUSTRATION 2

TOOLS REQUIRED

  • Measuring Tape
  • Marker
  • Power Tools
  • Screw Driver
  • Cutting Tools

PACKAGING INCLUDES

  • (1) Automatic Door Bottom
  • End Plate
  • Screw Pack

SURFACE MOUNTED OR SEMI-MORTISED APPLICATION

SURFACE MOUNTED
SEMI MORTISEDCAL ROYAL ADB-702 Automatic Door Bottoms - Figure
2CAL ROYAL ADB-702 Automatic Door
Bottoms - Figure 5

ILLUSTRATION 4 (Trimming Guideline)

CAL ROYAL ADB-702 Automatic Door Bottoms - Figure 7

TESTING / RATINGS:

GASKETING MATERIAL FOR FIRE DOORS INTENDED FOR APPLICATION TO UL LISTED STEEL FRAMES AND/OR CLASSIFIED STEEL COVERED  COMPOSITE TYPE, AND HOLLOW METAL TYPE FIRE DOORS RATED UP TO 3HRS; WOOD AND PLASTIC COVERED COMPOSITE TYPE FIRE DOORS  ATED UP TO 1-1/2 HRS; AND WOOD CORE TYPE FIRE DOORS RATED UP TO 20 MINUTES.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

CAL-ROYAL User Manuals

Related Manuals