CAL-ROYAL 8000V Vertical Rod Exit Device Reversible Installation Guide

June 3, 2024
CAL-ROYAL

CAL ROYAL - logo

8000V VERTICAL ROD EXIT DEVICE-RERVERSIBLE
INSTALLATION INSTRUCTIONS
LHR door shown , RHR door opposite

8000V Vertical Rod Exit Device Reversible

CAL ROYAL 8000V Vertical Rod Exit Device Reversible - Featured
Image

  1. Turn the threaded rod clockwise about 15mm to 20mm into the bottom latch
  2. Push the bar first and then pull the threaded rod in order to turn it 5mm to 10mm into the connection anticlockwise
  3. Push the top latch in order to turn the threaded rod anticlockwise 1 5 mm to 20mm into the top latch
  4. Push the bar again and turn the threaded rod into the connection clockwise about 5mm to 10mm
  5. Test the movement, and then tighten the nut , put on all the other parts.
    CAL ROYAL 8000V Vertical Rod Exit Device Reversible -
fig5

CAL ROYAL 8000V Vertical Rod Exit Device Reversible -
fig6CAL ROYAL 8000V Vertical Rod
Exit Device Reversible - fig7CAL ROYAL
8000V Vertical Rod Exit Device Reversible - fig8

  1. Turn the threaded rod clockwise about 15mm to 20mm into the bottom latch
  2. Push the bar first and then pull the threaded rod in order to turn it omm to 10mm into the connection anticlockwise
  3. Push the top latch in order to turn the threaded rod anticlockwise 15mm to 20mm into the top latch
  4. Push the bar again and turn the threaded rod into the connection clockwise about 5mm to 10 mm
  5. Test the movement, and then tighten the nut put on all the other parts. CAL ROYAL 8000V Vertical Rod Exit Device Reversible - fig13

CAL ROYAL 8000V Vertical Rod Exit Device Reversible -
fig14CAL ROYAL 8000V Vertical Rod
Exit Device Reversible - fig15

  1. Turn the threaded rod clockwise about 15mm to 20mm into the bottom latch
  2. Push the bar first and then pull the threaded rod in  order to turn it omm to 10mm into the connection anticlockwise
  3. Push the top latch in order to turn the threaded rod anticlockwise 15mm to 20mm into the top latch
  4. Push the bar again and turn the threaded rod into the connection clockwise about 5mm to 10 mm
  5. Test the movement, and then tighten the nut put on all the other  parts.
    CAL ROYAL 8000V Vertical Rod Exit Device Reversible -
fig20