CAL-ROYAL INT-440 Weather Seal Door Accessories Installation Guide
- June 5, 2024
- CAL-ROYAL
Table of Contents
CAL-ROYAL INT-440 Weather Seal Door Accessories
Adhesive Gasketing Seal around the door
Installation Guidelines for INT-440 Adhesive Gasketing
Door Frame Preparation:
Clean the door frame thoroughly with a good cleaning agent that removes any
particles that can affect the adherence of the gasket, dust, or cleanser
build-up. Check the frame surface if it is completely dry before installation.
Always use a cleaning agent that is not a petroleum base.
Preferred schedule for installation:
The best time (schedule) to install the ADHESIVE GASKET is when most of the
major work in construction has been completed or change occupancy maintenance
field of work. Where area is already in the cleaning phase of the project
timetable. This is important to avoid foreign particles on the frame and the
adhesive during installation.
Important Reminder and Notice:
- When handling the adhesive gasket, avoid extending or expanding the item. It may deform in size or affect the quality of the item.
- Apply steady straight pressure when installing the gasket. Use appropriate tools like seam roller to strengthen the gasket.
- Avoid expanding the material when applying pressure using roller.
- Inspect the gasket adhesion after a few hours that it has been installed.
- Make sure to apply enough pressure when putting the gasket in the HEAD JAMB.
Packaging includes:
- Frame cleaner (1 pc)
- Seal sticker (1pc)
Tools Required:
- Cutting tools
- Rugs
Installation Procedure:
- Measure the exact length of the hinge jamb, strike jamb, and header jamb before cutting the seal.
- Cut both ends of the upper corner of the gasket at 45°angle.
- Peel off roughly 18” of backing from the adhesive gasket strip. Be careful not to touch the adhesive or drag it on the ground.
- Place the adhesive gasket as illustrated below. DO NOT STRETCH MATERIAL. The use of a hand roller is highly recommended.
- Remove the next 18” of paper backing and repeat step #3 until the entire length of the seal is installed. If a pre-cut length overruns a top or side, stretching has occured. Remove it immediately and reapply.
- Once installed, apply firm pressure along the entire surface of the product to ensure proper adhesion to the frame.
- Check if the gasket is properly mounted around the perimeter of the door, thus prevents the foreign particles from coming inside and also helps to save energy from the HVAC system.
**** 6605 Flotilla Street, City of Commerce, CA 90040 U.S.A. | Website: www .cal-royal.com | Email: sales@cal-royal.com Phone: 323-888-6601 ; 800-876-9258 | Fax: 323-888-6699 ; 800-222-3316