COMPCOOLER COMP-DCHB-25 Quick Release Double Chambers Hydration Bladder User Manual
- June 5, 2024
- COMPCOOLER
Table of Contents
Quick Release Double Chambers
Hydration Bladder
Model: COMP-DCHB-25/40
Rev. A
Operation Manual
Compcooler Technology
Jan. 2021
COMPCOOLER Introduction:
Compcooler Technology specializes in working on personal cooling & heating systems for harsh conditions. Compcooler has established its resume as a manufacturer of Military, Electronic, and Medical cooling equipment. The employees at Compcooler’s state-of-the-art manufacturing facility have been producing liquid heating & cooling systems for over 15 years. Quality system: ISO9001 and AS9100 registered facility. Certifications for major items: CE, FCC, UL, PSE, CB, FDA.
Product Categories
- Personal ICE Water Circulation Systems
- Micro Refrigeration Chiller Units
- Liquid Heating & Cooling Chiller
- Liquid Cooling & Heating Garment
- Industrial Chiller Unit Module
- Customized Cooling Systems
Certifications for major items
Quality System
for facility
BACKGROUND OF PERSONAL COOLING SYSTEM
In conditions of extreme heat, people may be at risk of heat stress when the body is under stress from overheating. Heat stress is not only a serious condition for workers, but it can result in occupational illnesses and injuries, heat-related discomforts and illnesses include heat exhaustion, heat cramps, heat rash, or even heat stroke. Symptoms can range from profuse sweating to dizziness, cessation of sweating, and collapse. At greatest risk of heat stroke are the elderly, children, and people with medical conditions, however, even young and healthy individuals can succumb to heat if they participate in strenuous physical activities during hot weather. It will need immediate action to cool the person until help arrives.
LIQUID CIRCULATION COOLING SYSTEM
A liquid circulation cooling system is an active cooling solution, it can cool
the body temperature fast to decrease the incidence of thermal stress and heat
stroke while increasing comfort, safety, focus, and endurance. A liquid
circulation system includes a liquid circulation unit and a cooling garment.
Mini a pump circulates cold water from the chiller or ICE bladder to cooling
channels embedded on the cooling garment and continuously flows around the
body, it will keep the user’s body temperature at a comfortable and safety
range.
BENEFITS OF LIQUID COOLING SYSTEM
Reduction in body core temperature increased duration. Reduction in skin
temperature, decrease in hydration needs Reduction in heart rate, improve
mental acuity Reduction in sweat rate, maintain physical performance
COMPCOOLER Personal ICE Water Circulation Cooling System (PICS)
PICS includes a liquid circulation unit and liquid cooling garment. A mini pump circulates the cold ICE water from the bladder to a micro-tubing cooling channel embedded on the liner of the garment, it continuously flows around the body to reduce body core temperature and keep the user at a comfortable cool range in hot conditions.
Detachable Bladder: 1.5L, 2.0L, 3.0L, and 4.0L (Hydration)
Cooler Unit: 6L, 25L Cooler
Pump Control Unit:
ON/OFF mode: cold water circulation only
Flow control mode: 3 levels of water flow control
Temp control mode: precise temp control for circulation of liquid
Liquid Temperature range: 2°C-10°C (36 °F -50 °F ) Cooling time:
1-3 hours for 1.5L frozen bladder
3-6 hours for 3.0L frozen bladder
4-8 hours for 6L ICE Cooler
8-12 hours for 25L ICE Cooler
Operation Ambient: 10°C-65°C (36 °F -148 °F )
Quick Release Double Chambers Hydration Bladder
Model: COMP-DCHB-25/40
Introduction:
COMPCOOLER double chambers ICE Bladder was designed for personal ICE water cooling systems, it includes two chambers, the main chamber with a roll-top is for water freeze, and the other chamber with a screw-top is for cool water circulation.
Bladder Size and Applications
- 2.5L Hydration Bladder: Backpack Single Compartment and UniVest
- 4.0L Hydration Bladder: Backpack Single and double compartments
Bladder Size and Applications
- 2.5L Hydration Bladder: Backpack Single Compartment and UniVest
- 4.0L Hydration Bladder: Backpack Single and double compartments
COMPCOOLER, PERSONAL THERMAL TECHNOLOGY
Preparation: Unit Connection and Primary Circulation
Bladder Connection:
Fill water into Roll-Top, connect the bladder Outlet/Inlet #2 grey quick
fitting with backpack unit.
Checking: bladder no leaks, quick fittings connection is fine,
Vest Connection:
Connect backpack unit with cooling vest, once you hear a click, it’s in
position.
Checking: Vest no leaks, quick fittings connection is fine.
Start circulation:
Press the On/Off switch, Pump circulates water from the bladder into the micro
tubing cooling channels of the cooling vest, then return to the bladder. The
user may see the water flow back to the bladder from Inlet #2 Grey fitting.
Checking: Battery works fine, the pump works fine.
Mode A:
Cool Water Circulation and Hydration
Temp Range: 15℃ -20℃ (59℉-68℉) Frozen Bladder
Step I: Bladder Freeze
Fill water from the Roll-Top to the fill line. No water into Screw Tap before
the freeze.
Step II: Circulation Water
Fill circulation water from Screw-top
Step III: Bladder Connection
Connect the frozen bladder Outlet/Inlet #1 Blue quick fitting with backpack
unit
Step Ⅳ: Start circulation Press On/Off Switch, and the pump starts to
circulation, and the user may feel the cooling in 2-3 minutes
Cooling Performance :
Cooling time: 3-4 hours by 2.5L Bladder 5-6 hours by 4.0L Bladder
Temp Range: 15℃ -20℃ (59℉-68℉)
Hydration: ICE melts more than 60%
Mode B
Cold Water Circulation Temp Range: 2℃ -5℃ (36℉-41℉) Frozen Bladder
Step I: Bladder Freeze
Fill water into the Roll-Top to fill the line.
Step II: Circulation Water
Fill a small amount of circulation water from Roll-Top Waiting for 5-8 minutes
till Outlet/Inlet#2 fitting melt, then go to the next step.
Step III: Bladder Connection
Connect the frozen bladder Outlet/Inlet #2 Grey quick fitting with backpack
unit
Step Ⅳ: Start circulation
Press On/Off Switch, the pump starts to circulation, the user may feel the
cooling in 60 seconds
Cooling Performance
Cooling time: 2-3 hours by 2.5L Bladder
4-5 hours by 4.0L Bladder
Temp Range: 2℃ -5℃ (36℉-41℉)
Hydration: Not Available
Mode C:
Quick Cold Water Circulation
Temp Range: 4℃ -6℃ (39℉-43℉)
ICE Cubes
Step I: Bladder Freeze
Fill ICE Cubes from Roll-Top.
Step II: Circulation Water
Fill a small amount of circulation water from Roll-Top
Step III: Bladder Connection
Connect the frozen bladder Outlet/Inlet #2 Grey quick fitting with backpack
unit
Step Ⅳ: Start circulation
Press On/Off Switch, the pump starts to circulation, the user may feel the
cooling in 60 seconds
Cooling Performance
Cooling time: 1-2 hours by 2.5L Bladder 2-3 hours by 4.0L Bladder
Temp Range: 4℃ -6℃ (39℉-43℉)
Hydration: Not Available
Safety:
It is important to become thoroughly familiar with the manual and operating characteristics of the unit. It is the owner’s responsibility to assure proper operator training, installation, operation and maintenance of the unit. Observe all warnings can result in injury to the operator and severe mechanical damage to the unit.
Warranty:
Compcooler Warrants to the Original Purchaser that products sold shall be free
from defects material and workmanship for warranty period not exceed one year
from the date
of shipment. Compcooler agrees to correct the original user of this product,
either by repair or at the manufacturer’s election by replacement. This
warranty shall not apply if the defect or malfunction was caused by accident,
neglect, unreasonable use, improper service, or other causes not arising out
of defects in material or workmanship. The manufacturer’s sole obligation
under this warranty is limited to the repair or replacement of a defective
product and shall not, in any event, be liable for any incidental or
consequential damages of any kind resulting from the use or possession of this
product.
Personal Thermal Technology,
Keep your body cool and comfortable in harsh conditions!
COMPCOOLER, PERSONAL THERMAL TECHNOLOGY
www.compcooler.com
info@compcooler.com
IS09001 AS9100 Certified Facility