MEAN WELL RSP-1500 1500W Single Output Power Supply Instruction Manual
- June 5, 2024
- MEAN WELL
Table of Contents
MEAN WELL RSP-1500 1500W Single Output Power Supply
Features
- Universal AC input/ Full range
- Built-in active PFC function
- High efficiency up to 91%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 6000W (3+1)
- Built-in remote ON-OFF control/ remote sense/
- auxiliary power/ power OK signal
- Protections: Short circuit/ Overload/Over voltage /Over temperature
- Optional conformal coating
- 5 years warranty
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- Digital broadcasting
- RF application
SPECIFICATION
MODEL| RSP-1500-5| RSP-1500-12| RSP-1500-15|
RSP-1500-24| RSP-1500-27| RSP-1500-48
---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 5V| 12V| 15V| 24V| 27V| 48V
RATED CURRENT| 240A| 125A| 100A| 63A| 56A| 32A
CURRENT RANGE| 0 ~ 240A| 0 ~ 125A| 0 ~ 100A| 0 ~ 63A| 0 ~ 56A| 0 ~ 32A
RATED POWER| 1200W| 1500W| 1500W| 1512W| 1512W| 1536W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 150mVp-p| 150mVp-p|
150mVp-p| 150mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 4.5 ~ 5.5V| 10 ~ 13.5V| 13.5 ~ 16.5V| 20 ~ 26.4V| 24
~ 30V| 43 ~ 56V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1500ms, 100ms at full load
HOLD UP TIME (Typ.)**| 10ms at full load| 14ms at full load| 16ms at full
load
INPUT
| VOLTAGE RANGE| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| 0.95/230VAC 0.98/115VAC at full load
EFFICIENCY (Typ.)| 80%| 87%| 87%| 90%| 90%| 91%
AC CURRENT (Typ.)| 17A/115VAC 8A/230VAC
INRUSH CURRENT (Typ.)| 30A/115VAC 60A/230VAC
LEAKAGE CURRENT| <2.0mA / 240VAC
PROTECTION
| ****
OVERLOAD **Note.4**
| 105 ~135% rated output power
Protection type : Constant current limiting unit will shut down o/p voltage
after 5sec. Re-power on to recover
OVER VOLTAGE
| 5.75 ~ 6.75V| 13.8 ~ 16.8V| 17 ~ 20.5V| 27.6 ~ 32.4V| 31 ~ 36.5V| 57.6 ~
67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION
| OUTPUT VOLTAGE PROGRAMMABLE(PV)| Adjustment of output voltage
is allowable to 70 ~ 100% of nominal output voltage. Please refer to the
Function Manual.
CURRENT SHARING| Up to 6000W or (3+1) units. Please refer to the
Function Manual.
AUXILIARY POWER| 12V@0.1A(Only for Remote ON-OFF control)
REMOTE ON-OFF CONTROL| Please see the Function Manual.
REMOTE SENSE| Compensate voltage drop on the load wiring up to 0.3V.
Please refer to the Function Manual.
ALARM SIGNAL OUTPUT| Power OK signal. Please see the Function Manual.
ENVIRONMENT
| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 5)
| SAFETY STANDARDS| UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS
EN/EN62368-1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32)| Class B
Radiated| BS EN/EN55032 (CISPR32)| Class A
Harmonic Current| BS EN/EN61000-3-2| —–
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN55024, BS EN/EN61000-6-2, BSMI CNS13438
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT / Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS
| MTBF| 265.3K hrs min. Telcordia SR-332 (Bellcore) ; 90.3K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 27812783.5mm (LWH)
PACKING| 3.0Kg; 4pcs/13Kg/1.19CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Static Characteristics
MODEL
INPUT
| 5V| 12V| 15V
---|---|---|---
100~264VAC
| 1200W
240A
| 1500W
125A
| 1500W
100A
90VAC
| 960W
192A
| 1200W
100A
| 1200W
80A
MODEL
INPUT
| 24V| 27V| 48V
100~264VAC
| 1512W
63A
| 1512W
56A
| 1536W
32A
90VAC
| 1209.6W
50.4A
| 1209.6W
44.8A
| 1228.8W
25.6A
Derating Curve
Efficiency vs Load (48V Model)
Function Manual
Remote Sense
The Remote Sense compensates voltage drop on the load wiring up to 0.3V
Output Voltage Programming (or, PV / remote voltage programming / remote
adjust / margin programming / dynamic voltage trim)
In addition to the adjustment via the built-in potentiometer, the output
voltage can be trimmed to 70~100%(Typ.) of the nominal voltage by applying
EXTERNAL RESISTANCE
Connect an external resistor between TRIM(pin4) & -S(pin3 or pin4 or pin5) on CN1 or CN2, and +S & +V, -S & -V also need to be connected.
Remote ON-OFF
Remote ON-OFF is activated by the configuration with respect to CN1,CN2 and
CN3 as shown in the following diagram.
Connection Method
| Fig. 3.2(A)| Fig. 3.2(B)| Fig. 3.2(C)
---|---|---|---
SW Logic| Output on| SW Open| SW Open| SW Close
Output off| SW Close| SW Close| SW Open
Alarm Signal Output
Alarm signal is sent out through “POK” & “P OK GND” and pins on CN3. Please
acknowledge an external voltage source is required for this function
Function | Description | Output of alarm(P OK) |
---|
__
__
P OK
| The signal is “Low” when the power supply is above 65% of the rated output voltage, or say, Power OK| Low
(0.5V max at 10mA)
The signal turns to be “High” when the power supply is under 65% of the rated output voltage, or say,
Power Fail
| High or open
(External applied voltage 10mA max.)
1500W Single Output Power Supply
Current Sharing with Remote Sense
RSP-1500 has the built-in active current sharing function and can be connected
in parallel, up to 4 units, to provide higher output power as exhibited below
:
- The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
- Difference of output voltages among parallel units should be less than 0.2V.
- The total output current must not exceed the value determined by the following equation: Maximum output current at parallel operation=(Rated current per unit) (Number of unit)××0.9
Mechanical Specification
CN1 and CN2 are connected internally.
Pin No. | Function | Description |
---|---|---|
1 | RCG | Remote ON-OFF Ground |
2 | RC2 | Remote ON-OFF |
3,5,7 | -S | Negative sensing for remote sense |
4 | TRIM | Connection for output voltage programming |
6 | LS(Current Share) | Current Share |
8 | +S | Postive sensing for remote sense |
Control Pin No. Assignment (CN3) : HRS DF11-6DP-2DS or equivalent
Mating Housing | HRS DF11-6DS or equivalent |
---|---|
Terminal | HRS DF11-**SC or equivalent |
Pin No. | Function |
--- | --- |
1 | P OK GND |
2 | P OK |
3 | RCG |
4 | AUXG |
5 | RC1 |
6 | AUX |
AC Input Terminal Pin No. Assignment
Pin No. | Assignment | Diagram | Maximum mounting torque |
---|---|---|---|
1 | FG |
|
18Kgf-cm
2| AC/N
3| AC/L
Installation Manual
Please refer to : http://www.meanwell.com/manual.html