Alecto SA-16 Smoke Detectors User Manual

October 30, 2023
Alecto

Alecto SA-16 Smoke Detectors

Alecto SA-16 Smoke Detectors

Smoke detector for domestic use

The SA-16 is a smoke detector set for discovery of fire in the first stage. If smoke develops, the SA-16 will give a loud beep of at least 85dB (A). As part of the link function all the smoke alarms within range will sound the alarm. We advice to test the smoke detectors weekly using the test button on the detectors. Save this manual in a safe place or inside of the electricity meter cupboard.

RECOMMENDED INSTALLATION LOCATIONS FOR THE SA-16:

  • Install the first smoke detector near the bedroom. Ensure that it is placed so, if it would detect fire, at least one exit route would still be accessible. We recommend to place one alarm near each potential blockade of your exit route, so you are alerted before a fire would block off escape.
  • Use multiple smoke detectors to increase safety and ensure an alert before the escape route is blocked.
  • Install at least one smoke detector on each floor of your house.
  • Install at least one smoke detector in each room where people smoke or where there is equipment that may potentially cause a fire.
  • Smoke and heat will first move upwards towards the ceiling; after that the smoke and heat will travel horizontally.
  • Install the detector on the ceiling. Except for rooms smaller than 1m, you should stay at least 50 cm away from the wall and 60cm from any corner. Smoke and heat do not gather in such corners, preventing the detector from alerting you on time.

DO NOT INSTALL IN THE FOLLOWING LOCATIONS:

  • The kitchen; Steam from cooking might give a false alarm.
  • The shower or bathroom; water damp might cause a false alarm and the moist environment might damage the detector.
  • The garage: The car exhaust might cause a false alarm.
  • In front of a fan or nearby the exhaust of an air conditioner or heater.
  • In a ceiling nook.
  •  In rooms where the temperature could reach below 0°C or beyond 40°C.
  • Do not paint or otherwise cover this smoke detector.

INSTALLATION INFORMATION:

Attach the ceiling plate using the included plugs and screws to the ceiling on a location of choice. Wall mounting is not recommended for smoke detection. Put the 9V block battery in the smoke detector. Then put the detector to the ceiling plate and, twist clockwise to lock it in place. Perform a first test by holding the test key for 3 seconds. Also see the paragraph: “Testing”.
INSTALLATION INFORMATION

IMPORTANT:
For optimal operation, we recommend mounting the smoke detector on the ceiling. See also the installation instructions. If ceiling mounting is not possible, we recommend that you place the smoke detector in the middle of a wall. The installation location must be in the natural airflow of the room and free of side walls or slope.

USING, TESTING AND MAINTENANCE

Using

The smoke detector works if the 9V battery has been placed and the SA-16 has been mounted to the ceiling. The unit can only be mounted to the plate if the battery has been installed. The LED underneath the test button will now flash ± every 30 seconds. Once smoke is detected, the alarm will sound. Once the smoke disappears, the smoke alarm will stop automatically.

Hush function

The Hush function allows the user to decrease the smoke detectors sensitivity during an alarm. By pressing the “HUSH/TEST” button 2 – 3 sec the smoke detector is decreased for a period of 9 minutes. The red led flashes 1x every 9 seconds in Hush mode. After 9 minutes the smoke detector resets to its default sensitivity. For example, this can be used when the smoke detector gives alarm during cooking.

Time-out function

The time-out function allows you to preventively lower the sensitivity of the smoke detector. By pressing the “HUSH/TEST” button 2 – 3 sec without an active alarm, you reduce the smoke detectors sensitivity for 9 minutes. The red LED lights up 1x every 9 seconds during Hush mode. After 9 minutes the smoke detector resets to its default sensitivity. You can use this mode for example when you know that a situation (for example: cooking) will product smoke and there is no danger.

Test

Hold the test key for at least 3 seconds. The operation is still correct if you hear 2 or three signal tones. Check the smoke detectors weekly. In alarm status the smoke detector will generate about 85dB(A). Do not use candles, open fire or cigarettes to test the smoke detector.

ATTENTION

  • If the cause of an alarm is unclear, assume it’s caused by fire. Immediately evacuate the building.
  • Keep the smoke detectors out of range of children. Protect against dust during rennovations. Without protection the smoke detectors will lose their functionality.

Maintenance

The smoke detector is maintenance-free. In very dusty rooms they may be cleaned by vacuum.

PLAN AN ESCAPE ROUTE

  • Make a map and mark all locations of doors and windows and a possible escape route.
    Note that you may need an escape ladder on high floors.

  • Ensure everyone in the house knows the sound the smoke alarms produce and regularly practice use of the escape route.

  • Leave the house immediately according to the plan when hearing the alarm. Every second counts: so respond quickly. If you do not notice smoke or heat, check if everyone in the house is in a secure location.

  • Do not open any doors without feeling whether the door is warm or if there is smoke coming from underneath the doors. If it is, do not open that door. If the door is cold, put your shoulder firmly against the door and open it a small amount to check for any heat or smoke first.

  • If there is much smoke, keep low and take shallow breaths, preferably through a moist towel. Call the fire department as soon as you are safe outside.

REPLACING THE BATTERIES

The detector is supplied using a 9Volt blok battery. Only use the recommended type Gold Peak 1604A or Duracell MN1604. Under normal conditions the battery will last at least one year. If it is about to need replacement, the smoke detector will make a chirping sound every 30 to 40 seconds for at least 30 days. Pay attention to the polarity when replacing batteries. Test the detector after every battery replacement. If the smoke detector does not function, please contact your supplier.

ENVIRONMENT

Do not throw away used batteries, but recycle them using your local chemical depot. Product may not be thrown out as normal waste, but must be recycled as electrical waste.

DECLARATION OF Performance:
Is available at the following internet address:  http://DOC.hesdo.com /SA-16_DOP_1.pdf

‘S-Hertogenbosch
The Netherlands

Fire detection in buildings

Essential characteristic 1 : Pass
Essential characteristic 2: Pass
Essential characteristic 3: Pass
Essential characteristic 4: Pass
Essential characteristic 5 : Pass
Essential characteristic 6: Pass
Essential characteristic 7: Pass
Essential characteristic 8: Pass

WWW.ALECTO.NL
SERVICE@ALECTO.NL
‘s-Hertogenbosch,
The Netherlands

Alecto Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals