CJ LOGISTICS MPS3IND1 MPS 3.0 Indicator Instruction Manual

June 6, 2024
CJ LOGISTICS

CJ LOGISTICS MPS3IND1 MPS 3.0 Indicator Instruction Manual

1.Identification of each part

  1. Indicator Unique ID
  2. Function switch (M / F / C)
  3. Display LED & Main Push Button
  4. Function LED

2. Check the connection port and wiring

  1. Power cable. connection port (2pin)
  2. Lighting LED Connection Port & External Switch (OPTION). Connection port (4pin)

3. Front display

Front display
  1. Product number (QR code and text printed)
  2. 2.“M” / “F” / “C” button (M: Menu, F: Full, C:
  3. Blue 3 unit FND display
  4. Red 3 unit FND display
  5. Four colors (red, blue, green, yellow) LED display & main
  6. Company logo
  7. Auxiliary white LED

4. Product Introduction

  • MPI 3.0 Indicator was developed based on proprietary protocol networking for IoT technology and displays work instruction information received from Ex DPS / DAS Manager.
  • Dimension: 254 X 30 X 28 [mm] (Length x Width x
  • The case is matte black, the logo and product number are white, and the information display LEDs are red and blue.
  • The operation button indicates that the light is in stock in the direction of the incoming arrow
  • The Done button is available in four colors (green, orange, red, blue)

Specification

• Wireless| Sub-GHz
• Frequency| 919-923MHz ISM Band
• Data Rate

• Distance

• Interface

| ~250Kbps

~10m Power,

1 Output(LED),

5. Installation and Operation

– Push the Indicator from the front. – Insert the power cable into the bulkhead of the upper part of the guard.

6-1. Installation Tip

6. Register Indicators

  • Indicator registration using QR code

Each cell is assigned a unique QR code, and when it is scanned by the scanner, the unique QR code of the indicator to be newly registered is rescanned and
automatically registered to the server.

  • Equipped with separate LED lights

Attach it to each cell to use LED lights that work with the indicator to increase visibility of the operator to prevent job errors.
– Connect the optional LED bar for 5V to the 4pin connector

7. How to use

  1. Product code recognition by item Scan the bar code of the product you want to input.

  2. Distribution of required quantity for each destination It will identify the final quantity required to be shipped by dealers and display the goods code and quantity required in each indicator through the Gateway.
    At this point, the LED on the confirmation button indicates that it must be received.

  3. Check after loading goods Insert the quantity marked on the indicator for each delivery box and press the confirm button.
    When the confirm button is pressed, the status of the indicator changes to LED ON -> LED
    When all confirm buttons are pressed, the next item is scanned.
    Green LED’s mean that items must be loaded in green box, red LED’s in red box, yellow LED’s in yellow box, and blue LED’s in blue box.

  4. When all goods have been loaded, the invoice is printed.

8. Connector Definition

1. Power Connector
  1. GND
  2. VCC (12V)

2.Auxiliary 4 4-pin

  1. EXT_LED(5V)
  2. GND
  3. SW_EXT
  4.  SW EXT Return

3. F/W Upgrade connector

  1. VMCU_IN
  2. SWCLK
  3. SWDIO
  4. GND

10. Power and External Connections

  • The MPI 3.0 Indicator has the following ranges of supply power and voltage ranges.
    -Input voltage range: DC6V ~ DC12V
    -Maximum power consumption: <15W
  • The MPI 3.0 Indicator supports the following external interfaces:
    -Secondary Switch
    -LED bar for auxiliary lighting (DC 5V only)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

Modifications: Any modifications made to this device that are not approved by CJ
Logistics Corporation may void the authority granted to the user by the FCC to operate this equipment.
Indicator & Gateway has been used to facilitate the delivery of various instructions for the work performed in the logistics distribution to the field workers.
This device is Class A than Class B since it is using for Industrial not for household.

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals