electriQ AQUA-DRY 5L Compressor Dehumidifier User Manual
- June 12, 2024
- ElectriQ
Table of Contents
- AQUA-DRY 5L Compressor Dehumidifier
- QUICK VISUAL SAFETY GUIDE
- FEATURES
- INSTALLATION
- POSITIONING THE DEHUMIDIFIER
- PARTS
- CONTROL PANEL
- DISPLAY
- WATER DRAINAGE
- CARE AND MAINTENANCE
- FREQUENTLY ASKED QUESTIONS
- TROUBLESHOOTING
- TECHNICAL DATA
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AQUA-DRY 5L Compressor Dehumidifier
User Manual AQUA-DRY
AQUA-DRYB
5 LITRE COMPRESSOR DEHUMIDIFIER
AQUA-DRY 5L Compressor Dehumidifier
Thank you for choosing electriQ.
Please read this user manual before using this innovative dehumidifier and
keep it safe for future reference
Visit our page www.electriQ.co.uk for our entire
range of Intelligent Electricals
SETTLING IN OK?
We hope this has been helpful to you.
We would love to see how you’re getting on with your new purchase,so please
share any snaps you have on the platform of your choice below.
Our community awaits your uploads – Snap, tag and hashtag away!
@electriQUK
#electriQUK
WE’RE HERE TO HELP
Should you have any problems or questions with your purchase, please contact a
member of our customer service team.
0330 390 3061
****support@electriQ.co.uk
Mon-Fri | 9am to 5pm
Unit J6, Lowfields Business Park,
Lowfields Way, Elland
West Yorkshire, HX5 9DA
SAFETY INSTRUCTIONS
IMPORTANT
- Carefully read the instructions before operating the unit
- This appliance is for indoor use only and intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injury to user or property.
- Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
- Installation must be in accordance with regulations of the country where the unit is used.
- If you are in any doubt about the suitability of your electrical supply have it checked and if necessary, modified by a qualified electrician.
- This dehumidifier has been tested and is safe to use. However, as with any electrical appliance – use it with care.
- Disconnect the power before dismantling, assembling or cleaning.
- Avoid touching any moving parts within the appliance.
- Never insert fingers, pencils or any other objects though the guard
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Do not leave children unsupervised with this appliance.
- Do not clean the unit by spraying it or immersing it in water.
- Never connect the unit to an electrical outlet using an extension cord. If a power outlet is not available, one should be installed by a qualified electrician.
- Never operate this appliance if the cord, power adapter or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges.
- A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
- Any service other than regular cleaning or filter replacement should be performed by an authorised service representative. Failure to comply could result in a voided warranty.
- Do not use the appliance for any purpose other than its intended use.
- Do not tilt the unit while in use. The unit is design to work only in vertical position.
- This dehumidifier must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
- Avoid restarting the dehumidifier unless 5 minutes have passed since being turned off. This prevents damage to the compressor.
- Never use the plug as a switch to start or turn off the dehumidifier. Use the provided Power button located on the control panel.
- Always place the unit on a dry and stable surface.
- The appliance should not be installed in laundry or wet rooms where the humidity is higher than 85% RH
- Do not dry laundry above the unit to prevent water entering the dehumidifier. Place the laundry at least 1 meter away from your dehumidifier.
- Before moving the appliance the water tank should be emptied.
- When carrying the unit, it should be kept upright and suifficiently supported from its base.
- The appliance must be placed in a room without sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater).
- R290 refrigerant gas complies with European environmental directives.
- R290 has a low GWP (Global Warming Potential) of 3.
- The AQUA-DRY contains about 30g of R290 refrigerant gas.
- Do not use or store the appliance in an unventilated space with an area smaller than 4m2 per unit.
- If the appliance is installed, used or stored in an unventilated room, the room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
- Refrigerant gas may be odourless.
- Do not use the product and contact the retailer for advice, if damage has occurred to the unit which may have compromised the refrigerant system.
- Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized.
- The refrigerant system should not be perforated or punctured.
- Do not place the unit next to heat sources (e.g. electrical fires, fireplaces, etc.)
- Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to its internals and increases the risks of operating it.
- Do not store or use gasoline, petrol, paint, solvents or other flammable vapours or liquids in the vicinity of this dehumidifier or any other appliance.
- This dehumidifier must not be used in spaces where there is a high concentration of gases, solvent or other volatile organic compounds; in very dusty environments; in any domestic, commercial or industrial environment where the air composition is flammable.
ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS
- Do not cover or restrict the airflow from the outlet or inlet grills. Do not operate and follow troubleshoot procedure if the self-opening louvers do not open on power on.
- For maximum performance the minimum distance from a wall or objects should be 20 cm
- Keep the filters or grills of the unit clean. Under normal conditions, filters or grills should only need cleaning once every three weeks (approximately).
- Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality. Vacuum both mesh and optional carbon filters and wash the mesh filters with hot soapy water and dry them before placing them back in the unit.
QUICK VISUAL SAFETY GUIDE
ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER
FEATURES
Your dehumidifier belongs to the electriQ dehumidifier range.
- Easy to use controls
- Lightweight and portable
- Cost effective way to combat mould, condensation and damp
- Designed to complement any modern space
- Intelligent CPU controlled digital humidistat with 35-80% RH and room humidity display
- 24 hours stop timer
- Easy to remove front tank.
- Tank operation or permanent drainage option
- Tank full alarm & auto-stop function
- Auto restart following power cut.
- Ioniser and optional carbon filter to improve air quality
INSTALLATION
Remove any water from within the water tank before starting the unit. In order
to save energy do not open windows or doors while the unit is running. Place
the unit on a hard / flat surface. On first use run the unit continuously for
24 hrs.
TO REDUCE NOISE LEVELS:
Place a piece of carpet or a rubber mat under the unit to reduce any
vibrations while the unit is running.
The AQUA-DRY dehumidifier uses compressor technology to extract water from the
environment. Compressor dehumidifiers are ideal for normal domestic or office
environments which are heated during the winter months and maintain a
temperature above 12-15⁰C.
Your dehumidifier is lightweight and easy to move. It is designed to extract
unwanted humidity while saving money due to its power saving logic. The unit
features an intelligent humidistat where the desired relative humidity can be
adjusted in increments of 5% between 35 and 80% ensuring your room is not
dried too much and power is not wasted.
POSITIONING THE DEHUMIDIFIER
A badly positioned dehumidifier will have little effect. In positioning the
dehumidifier please ensure circulation of air in not restricted around the
unit.
Allow at least 20 cm space around the unit. This dehumidifier is designed only
for indoor residential or small office applications and any commercial or
industrial use will invalidate the warranty.
Use in an enclosed area for maximum efficiency. Close all doors, windows to
create an effective operating environment. Do not use outdoors.
Your electriQ dehumidifier will
begin to protect your space from the harmful effects of excessive moisture as
soon as it is turned on. Excess moisture is dispersed throughout your home.
For this reason, the dehumidifier should be positioned in a central and clear
location so that it can draw this moist air towards it from all over the home.
A warm hallway or landing is an excellent position for your dehumidifier. If
possible, leave interior doors ajar to allow air circulation.
Alternatively, if you have a serious problem in one area you can begin by
positioning the dehumidifier there and moving it to a more central location at
a later date. For the most effective use, run your dehumidifier with external
doors and windows kept closed. Please note the unit should not be placed
directly against a radiator or other heat source.
Before moving the appliance the water tank should be emptied. When carrying
the unit, it should be kept upright and suifficiently supported from its base.
When positioning your electriQ dehumidifier, ensure that it is placed clear of
any obstacle that may limit the air movement. Place the dehumidifier on a flat
dry surface.
PARTS
OPTIONAL
To fit the filters, remove the filter frame from tha air inlet, and place them
flush within the air inlet. If using both the Carbon and HEPA filters in
combination, the Carbon filter should be inserted first.
CARBON FILTER (Supplied)
Used for the removal of odours. Replacement Activated carbon filters are
available from the retailer under reference: CARBON-AQUADRY HEPA
FILTER (Not Supplied)
Used for the removal of airbourne particles. HEPA filters are available from
the retailer under reference: HEPA-AQUADRY
CONTROL PANEL
| POWER BUTTON
Turn the appliance on/off.
Note: When the power light is flashing the unit is in defrost mode
---|---
| MODE BUTTON
Select the operating mode of the unit between Smart and Air Purifier.
SMART MODE: The unit will start dehumidifying when the humidity increases
to 5% above the desired humidity and will stop when the humidity drops to 5%
below the desired humidity. The default desired humidity is 55% RH. Use the
humidity button to adjust the desired humidity.
AIR PURIFIER MODE : The fan will run with no dehumidifying effect. This
is ideal when only wanting to use the unit as an air purifier. This can also
be used in combination with the ioniser function.
| HUMIDITY BUTTON
Repeatedly press to adjust the desired humidity — The currently selected level
will be shown on the display. This button is also used to change the duration
of the timer following pretting the TIMER button
| IONISER BUTTON
Press to turn the ioniser on and off. The ioniser indicator will illuminate to
show the feature is activated.
| TIMER BUTTON
Press the TIMER button to program the timer. When the timer is activated the
“TIMER” light will be illuminated. Before programming the timer, ensure the
timer function has not been activated (the light must be off). The following
timer programs are available.
DELAYED POWER-OFF FUNCTION: While the appliance is running with the
desired settings, press the TIMER button to initiate the timer and then
repeatedly press the HUMIDITY BUTTON to set in how many hours time you require
the unit to stop (0″’24 hours).
DELAYED POWER-ON FUNCTION: While the appliance is in standby, press the
TIMER button to initiate the timer and then repeatedly press the HUMIDITY
BUTTON to set in how many hours time you require the unit to start (0-24
hours). The unit will operate with the previously used settings.
| SLEEP BUTTON
Press the button to activate sleep mode.All indicators other than the sleep
indicator will turn off.
Press and hold the button for 3 seconds to lock the control panel. The lock
indicator will illuminate. When the lock is initiated, the unit will also
enter sleep mode. To avoid this, the unit should be put Into sleep mode before
activating the lock.
DISPLAY
During normal operation shows the current humidity of the room.
Shows the desired humidity when the HUMIDITY button is pressed Shows the timer
duration when the TIMER button is pressed
NOTES
- If a permanent drainage pipe is fitted the unit will not stop operating. Setting the desired humidity to around 35% is good for laundry mode, a quick drying boost, or in emergencies. It is not recommended for long normal operation in a domestic or office environment.
- To allow more moisture in the air, set a higher desired humidity (e.g. 60-70%).
- We recommend setting the desired humidity to 50-55%. This is great for domestic operation and dry storage
- Setting the humidity to 60% is great for personal comfort and applications where 50% RH is considered too dry
- Setting the humidity to 70% is ideal for unoccupied properties or where an economical run is needed without the need to reduce the humidity further.
OTHER FEATURES AND INDICATORS
TANK FULL INDICATOR
When the water tank is full, removed or incorrectly inserted the unit will
stop dehumidifying, and the TANK FULL indicator will illuminate. Empty the
tank and reinsert it correctly to resume operation.
AUTO DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off
and the unit will go in to defrost ode. Following completion of the defrost
mode, the unit will return to the previously operating settings.
- When the unit is running in a room with a temperature between 5℃ and 12℃,it will enter defrost mode for 8 minutes roughly every 20minutes.
- When the unit is running in a room with a temperature between 12℃ and 18℃,it will enter defrost mode for 8 minutes roughly every 25minutes.
- When the unit is running in a room with a temperature between 18℃ and 23℃,it will enter efrost mode for 8 minutes roughly every 120minutes.
POWER
After the unit has stopped, to protect the compressor it is not recommended to
resume operation for at least 5 minutes. Operation can resume after this
period lapses. When the unit is restarted there is a 3 minutes delay before
compressor will start.
WATER DRAINAGE
When the water tank is full, the unit will stop automatically. When this
happens the TANK FULL indicator will illuminate
NOTE: Only empty the water tank when it is full or before moving or storing
the unit.
There are two ways to dispense collected water.
USE THE TANK
When the tank is full, the unit will automatically stop running, and the TANK
FULL indicator will illuminate. Slowly pull out the tank. Empty the water tank
and reinsert it into the dehumidifier. The tank must be in place and securely
seated for the dehumidifier to operate again. The dehumidifier will re-start
when the tank is restored in its correct position.
NOTES:
When you remove the water tank, do not touch sensors or any parts which are
situated behind tank.
Doing so may damage the product. Be sure to push the tank gently all the way
into the unit. Banging the bucket against anything or failing to push it in
securely into place may cause the unit not to operate.
Do not remove any parts from the water tank or tank enclosure. The water full
sensor will no longer be able to detect the water level correctly and water
may leak from the water tank.
CONTINUOUS DRAINAGE
Water can be automatically plumbed in or drained into a sink, a larger
recipient or through the wall into an outside drain by attaching a pipe to the
unit. Remove the rubber bung on the rear of the unit and insert the pipe into
the drain outlet at the back of the unit.
Make sure the connection between pipe and the drain outlet is tight and does
not leak. Then direct the pipe to a suitable drainage point. This unit uses
gravity to dispose of water hence the drain should be lower than the water
outlet on the unit. Put the tank back. Be sure to run the water pipe downward
and let the water to flow out smoothly. Do not kink or bend the pipe.
The permanent drain can be used in conjunction with an external water pump
(e.g. when draining from a cellar) to lift the water upwards.
CARE AND MAINTENANCE
Always shut off the unit and unplug from the mains before cleaning or
performing any maintenance. When it is not in use for long periods it is
advisable to remove the plug from the power socket. Do not use chemical
solvents (such as benzene, alcohol or gasoline) as they may cause irreversible
damage to the unit.
1. CLEAN THE GRILLE AND CASE
Use water and a mild detergent to clean the washable filter frame. Do not use
bleach or abrasives. Do not splash water directly onto the main unit. Doing so
may cause an electric shock and can lead to the insulation to deteriorate, or
cause the unit to rust. The air intake and outlet grilles get soiled easily,
so use a vacuum attachment or soft brush to clean. Wipe the dehumidifier body
with a sof t damp cloth or kitchen towel. Remove the filter frame. If the optional carbon filters are
fitted, remove them from the frame and hoover gently approximately every 2-3
weeks.
If the mesh filter is dirty hoover it, if it is heavily soiled wash it with
warm soapy water and dry thoroughly before reinserting it in the unit.
When filter cleaning is finished and filters are dry placed them back into the
unit. NOTE: While the carbon filter is optional, never run the unit
without the filter frame correctly inserted.
2. CLEAN THE WATER TANK
Every few weeks, clean the tank to prevent growth of mould, mildew and
bacteria. Partially fill the tank with clean water and add a little mild
detergent. Swish it around and than empty the tank and rinse.
NOTE: Do not use a dishwasher to clean the tank. After cleaning and drying,
the tank must be reinserted securely into dehumidifier in order to restart
operation. END OF SEASON MAINTENANCE
- Run the unit for at least 30 minutes in Air Purifier mode, this will allow the unit to internally dry.
- After 30 minutes, empty and clean the water tank, ensuring it is fully dry before reinserting into the unit.
- Clean the unit and the filters as per cleaning procedure above.
- Coil the power cord on the special cord storage rest at the back of the unit
- Cover the unit and keep it in a dry place.
FREQUENTLY ASKED QUESTIONS
Why doesn’t the dehumidifier seem to extract much water if the temperature is low?
This is a compressor dehumidifier which works best in temperatures above 15⁰C. If the temperature is low and the air is dryer than the setting on the humidistat the unit will not extract water. If you want to use a dehumidifier for outside buildings, unheated properties, boats or garages please check our desiccant range.
Why doesn’t the unit work /or stops suddenly?
The water tank may be full or displaced. To rectify: empty the tank and carefully place the tank back in the unit. Also the unit may be running in dehumidifying mode with a low room temperature. Please check if the room temperature is lower than 5⁰C. If so, the unit will stop working while in dehumidifying mode. (unit may be defrosting). The ambient operating range is between 5⁰C and 35⁰C with a relative humidity ranging from 35% to 80%. For maximum efficiency use the unit between 15⁰C and 32⁰C.
Sometimes cold and/or hot air comes out from the air outlet grill, why?
When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the humidity. During the cold cycle there should be cold air coming out of the unit. During the hot cycle hot dry air should be coming out of the outlet grill.
TROUBLESHOOTING
Issue | Cause | Solution |
---|---|---|
Hot or cold air being produced | Normal Operation | When the unit is in |
dehumidifying mode it absorbs humid air from room and freezes it to reduce the
humidity.
During the cold cycle there should be cold air coming out of the unit During
the defrost cycle hot dry air should be coming out of the outlet grill.
Unit does not operate| Is the plug properly inserted in the socket?| Insert
the plug into the socket and turn the switch on.
Is E2 displayed on the control panel| Tank full, float displaced or tank not
properly inserted. Empty tank, check float and make sure tank is properly
inserted in unit.
Dehumidifier does not extract
water| Is the unit set to a humidity level
lower than the one in the room?| Set the humidity level on the humidistat
bellow current humidity reading.
Is the temperature too low for water extraction to be efficient?| Increase
temperature in the room or reposition the unit.
Is any intake grill or discharge blocked? Is the unit too close to walls.|
Remove obstructions and restart the unit.
Ensure a distance of at least 20 (cm between the unit & walls
Airflow seems weak| Is filter dirty or clogged?| Please service the filters
regularly as per user manual.
Unit is noisy during operation| Is the unit on an uneven surface?| Please
place on flat horizontal surface.
is filter clogged?| Please service the filters regularly as per user manual.
E3 or E4| Humidity sensor error| Use the unit within the prescribed humidity
range. Unplug the unit rest and plug it back in. If error repeats. call for
service center.
El or E2| Temperature sensor error| Use the unit within the prescribed
temperature range.Unplug the unit rest and plug it back in. If error repeats.
call for service center.
Tank full indicator light| Water tank full notification| Tank is full or is
not in the right position. Empty the tank and replace in the right position.
Any other malfunctions will need to be reported to electriQ service centre. Do
not attempt unauthorised repairs as these may invalidate the warranty.
TECHNICAL DATA
Model | AQUA-DRY / AQUA-DRYB |
---|---|
Voltage | 220-240V~50Hz |
Dehumidifying capacity | 5L / day (at 30⁰ C / 80%RH) |
Fan Speeds | 1 |
Rated Input Power | 155W |
Running Amps | 0.7 Amps |
Tank Capacity | 1.5 litres |
Desired Humidity Range | 35 – 80% |
High / Low Pressure | 3.2/0.7MPa |
Filters | Carbon (Optional) |
Weight (Kgs) | 7 |
Refrigerant | R290, 30 grams |
GWP | 3 |
Disposal: Do not dispose this product as unsorted waste.
Collection of such waste must be handled separately as special treatment is
necessary.
Recycling facilities are now available for all customers at which you can
deposit your old electrical products. Customers will be able to take any old
electrical equipment to participating sites run by their local councils.
Please remember that this equipment will be
further handled during the recycling process, so please be considerate when
depositing your equipment. Please contact the local council for details of
your local household waste recycling centres.
electriQ UK SUPPORT
www.electriQ.co.uk/support
Please, for your own convenience, make these simple checks before calling the
service line.
- Has the unit been standing upright for at least 2 hours?
- Is the unit plugged into the mains?
- Is the fuse OK?
- Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.
- Check if the water tank is full.
- Was the troubleshooting guide followed?
If the unit still fails to operate call: 0330 390 3061 or complete the online
form
Office hours: 9AM – 5PM Monday to Friday
Unit J6, Lowfields Business Park,Lowfields Way, Elland
West Yorkshire, HX5 9DA