NSL YH-HRF50D120S-283580WW 120V AC LED Estrip Installation Guide

June 4, 2024
nsl

NSL YH-HRF50D120S-283580WW 120V AC LED Estrip

NSL YH-HRF50D120S-283580WW
120V AC LED Estrip product

MAINTENANCE

Do not modify this fixture. Any modifications may render the product unsafe and void warranty.

Limited Warranty

The warranty applies to the product from the original date of purchase for five (5) years against manufacturing defects. The owner must provide a copy of the original proof of purchase. The manufacturer’s obligation under this warranty is limited to repairing or replacing the component. It is not related in any way to the cost of the connection, the installation of the replacement parts or cost of transport.

installation

  1. Cut the Estrip to desired length at the cut marks, using a sharp knife or scissors.
  2. Apply glue inside the end cap. Attach the end cap to cover the end of the Estrip. Wipe the excess glue with a dry towel.
  3. Line up the barbed side of the pins with the wires of the Estrip. Push barbed pins into the Estrip, making sure to make solid contact with the internal wires.
  4. Apply glue inside the power feed connector sheath, then push the cord sheath onto the assembly until fully seated. Align the black wire of the power feed connector to the (+) and the white wire with the (-) on the Estrip. Wipe any excess glue with a clean towel. Let the assembly to dry for several hours.
  5. When installing jumper connectors, repeat steps 3 & 4, making sure the connections have the correct polarity.
  6. For surface installation, use mounting clips or aluminum mounting channels, as per your application requirements.NSL YH-HRF50D120S-283580WW 120V AC LED Estrip fig 1

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

nsl User Manuals

Related Manuals