nsl wall sconce light User Guide
- June 5, 2024
- nsl
Table of Contents
nsl wall sconce light
WIRING AND MOUNTING INSTRUCTIONS
CAUTION! Only qualified electricians or people familiar with household
electrical circuits should bring 120VAC power to the fixture. Wiring may
require an inspection by local authorities building department. Check with
your local building department before installation.
CAUTION! Before bringing 120VAC power to the fixture, make sure incoming wire
is not “hot” and all power coming to the wire is off.
CAUTION! All connections must be made in accordance with this instruction
manual, current NEC/ CEC and all local building codes. Minimum 90C supply
conductors.
-
The Wall Sconce Light fixture mounts to a standard octagonal junction box with mounting screws provided.
-
Remove the fixture’s diffuser.
-
Strip 1/3″ (8mm) of the insulation off each incoming 120VAC power wire. Connect white incoming 120VAC wire (neutral wire) to the white wire from the fixture and secure with wire nut provided. Connect black incoming 120VAC wire to the black wire from the fixture and secure with wire nut provided. The electrical box you are mounting to should have ground connection to it. Thread all wires firmly
down into wire nuts, so that uninsulated wire is not exposed. -
Mount fixture to the junction box using the mounting bracket and the screws provided.
-
Replace the diffuser
WALL SCONCE LIGHT DIMMING
Wall Sconce Light is dimmable to about 5% with most standard dimmers.
- Junction Box
- Junction Box Ground Wire
- Fixture Ground Wire
- Junction Box White Wire
- White Fixture Wire
- Junction Box Black Wire
- Wire Connector
- Black Fixture Wire
- ED Circuit Board
- Fixture Housing
- LED Circuit Board
- Diffuser
- Screws
- Mounting Bracket
- Ground Screw
- Ring
WARNING AND CAUTIONS
Caution /Warning! To reduce the risk of fire, electric shock or injury to persons:
- Disconnect from all 120VAC power prior to installation.
- Connections must be made in accordance with all local electrical codes and or NEC/CEC.
- Minimum 90C supply conductors.
- For maximum load with dimmer, consult dimmer instructions.
- 14 gauge (Romex Type) or better wire is required to feed electrical box (supplied by others)
- Install in accordance to manufacturer’s instructions, current local codes and or the current Canadian Electrical Code or National Electrical Code. THIS
PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
SPECIFICATIONS
- Electrical Rating:
- Input Voltage: 120VAC+-10%
- Power Consumption: 15w
- Colour Temperature: 300oK
- CRI: 80
- LED Luminous flux: 1200 lumens
- Beam Pattern: 120 degrees
- LED Life: 50,000 hours to 70% lumen output
- Approvals Listing: ED.