Introduction
Thank you for purchasing the 600A1 Moisture Monitor System. This system is designed to monitor the moisture of the forage crop and to plug directly into the baler’s ISOBUS and display on a C1000 monitor. The 600A1 Moisture Monitor System offers these advantages:
- Operation coordinated with baler operation
- Less cab clutter provides better visibility
- Ease of use with all information on one screen
- Records kept together
- And the system is ready for future updates.
The 600A1 Moisture Monitor kit includes the following parts: Dual Channel Processor (DCP), Moisture Sensors, Harnesses, and Miscellaneous Hardware. For your convenience, a parts breakdown for the model 600A1 is included in the back of this manual. If you do have questions bring this manual to the dealership. They can assist you in ordering the correct replacement parts. The 600A1 Moisture Monitoring System can have a complete preservative applicator added as well as the tagging option to enhance the system at any time. Contact your local dealer for more information. Right, and Left sides are determined by facing in the direction of forwarding travel.
System Requirements
The Baler Processor must have Version 3.3 or higher.
Tools Needed
- Standard wrench set
- Electric drill and bits
- Side cutter
- The standard nut driver set
- Standard socket set
- Hammer & Center Punch
Safety
Carefully read all safety signs in this manual and on the moisture sensor kit before use. Keep signs clean and clear of obstruction to view. Replace missing or damaged safety signs. Replacement signs are available from your local authorized dealer. See your installation manual under the replacement parts section for the correct part numbers. Keep your moisture sensor kit in proper working condition. Unauthorized modifications to the moisture sensor kit may impair the function and/or safety of the machine. Carefully read and understand all safety signs before installing or servicing.
Installing the 600A1 Moisture Sensor Kit
Mounting the Dual Channel Processor (DCP)
Locate the Dual Channel Processor (006-6671LS), four 5/16” x 1” hex bolts,
flats, locks, and nuts. Mark, and drill four 3/8” (9.525 mm) holes following
the template shown below. The whip wire extension on the DCP should be facing
down when attached to the baler. Mount the DCP cover (001-5650X) over the DCP
and secure the hardware.
Installing Star Wheels
The star wheel block has a plug on one side and a wire grommet on the other side. If there is interference or problems with the star wheel wires on one side of the block, exchange the wire grommet with the plug so the wire can exit the block on the opposite side. Mount the twine guards using the two inner holes on the star wheel block. The star wheels are to be mounted on top of the baler just behind the knotters and under the walkway on both sides. The notch and holes for the star wheels are pre-cut. Place the spacer plate (001-6707E) over the pre-cut holes. Attach with 5/16” x 1/2″ Allen head bolts and internal star washers from inside the bale chamber. Center the star wheels over the top of the spacer plate, place the twine diverters on top of the star wheel and attach with 5/16” x 2-1/4” hex bolt and lock washers. For the remaining two holes of each star wheel attach with a 5/16” x 2-1/4″ hex bolt, lock washer, and one 5/16” thick flat washer per bolt. Verify the star wheels align with the bale chamber before tightening all hardware. (The twine guard with the two additional holes should be placed on the right side of the baler looking from the rear).
Wiring Installation
Connecting to the Baler Harness
Connecting the Star Wheels to the DCP
Locate the moisture harness (006-4640E2). Remove the four pan head screws on each star wheel and loosen the grommet. Insert the eye loop of the wire into the star wheel block and install on the end of the swivel. Leave a loop in the wire to allow the star wheel cover space to be reinstalled. Tighten the swivel nut, followed by the grommet, and finally install and tighten the four screws. The picture to the right shows the star wheel block open with the wire looped and attached to the swivel. Once both wheels are complete route the harness towards the DCP on the back right twine box. Be sure to mount and secure all harnesses away from hydraulic lines and moving parts.
Connecting the Harnesses to the DCP
- Install the green-capped terminating resistor (006-5650Z) to the Dual Channel Processor (DCP).
- Route the communication harness (006-6650VC) from the baler to the DCP. Attach the harness to the whip harness coming off the base of the DCP. Secure harness from DCP to baler communication port.
- Install the baler’s black terminating resistor to the open end of the communication harness (006-6650VC) next to the DCP.
- Install the moisture harness (006-4640E2) into the DCP at the port marked Moisture Sensor. Secure harness from DCP to star wheels.
Controls and Harnesses
Star Wheel Sensors
Harvest Tec, LLC. Warranty and Liability Agreement.
Harvest Tec, LLC. will repair or replace components that are found to be
defective within 12 months from the date of manufacture. Under no
circumstances does this warranty cover any components which in the opinion of
Harvest Tec, LLC. have been subjected to negligent use, misuse, alteration,
accident, or if repairs have been made with parts other than those
manufactured and obtainable from Harvest Tec, LLC. Our obligation under this
warranty is limited to repairing or replacing free of charge to the original
purchaser any part that in our judgment shows evidence of defective or
improper workmanship, provided the part is returned to Harvest Tec, LLC.
within 30 days of the failure. Parts must be returned through the selling
dealer and distributor, and transportation charges prepaid. This warranty
shall not be interpreted to render Harvest Tec, LLC. liable for injury or
damages of any kind, direct, consequential, or contingent, to persons or
property. Furthermore, this warranty does not extend to loss of crop, losses
caused by delays or any expense prospective profits, or for any other reason.
Harvest Tec, LLC. shall not be liable for any recovery greater in amount than
the cost or repair of defects in workmanship. There are no warranties, either
expressed or implied, of merchantability or fitness for a particular purpose
intended or fitness for any other reason. This warranty cannot guarantee that
existing conditions beyond the control of Harvest Tec, LLC. will not affect
our ability to obtain materials or manufacture necessary replacement parts.
Harvest Tec, LLC. reserves the right to make design changes, improve design,
or change specifications, at any time without any contingent obligation to
purchasers of machines and parts previously sold.
Revised 6/22
HARVEST TEC, LLC.
P.O. BOX 63
2821 HARVEY STREET HUDSON, WI 54016 PHONE:
715-386-9100
1-800-635-7468
FAX: 715-381-1792
Email: info@harvesttec.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>