BORMANN BDM6000 Laser Distance Meter User Manual
- June 3, 2024
- BORMANN
Table of Contents
BORMANN BDM6000 Laser Distance Meter
Safety instruction
Instrument application
- Indoor distance measurement
- Area and volume calculate
Disenable
- Use the instrument without reading this manual
- Use the instrument outside the scope of specified application
- Destroy the security system, take off or dangerous signs
- Open the meter by tools (such as a screwdriver)
- Update or change the instrument
- Use the accessories which not evaluated by our company, or other company accessories
- On the scaffolding, climb ladders, use the instrument near the measuring idling machine or close to the no protection facilities equipment, or irresponsible action
- Direct aim at the sun
- Shake or shine the others on the dark place deliberately
- measured on the place without safety facilities (such as on the road etc.)
Laser Rank
This product has no visible laser, it transmit in the front of the instrument
This product is the second grade laser products, according to the following
standards:
1 EC60825-1: 2007 “Laser radiation safety products” Second grade laser
product:
Don’t look straight into the laser beam; don’t aim for others in the case of
unnecessary. Eyes will instinctively turn by visual or blink action to take
self preservation.
warning!
Through the optical lens (such as the eyepiece, telescope, etc) direct laser
beam, will do harm to the eyes Prevention measures:
Don’t look through lenses laser beam
Be careful!
It will do harm to the eyes when look straight into the laser beam. Prevention
measures: Don’t look straight into the laser beam. Pay attention to make the
laser beam on the eyes or below the shot. (Especially in the instrument fixed
under the condition of mechanical equipment quality. )
Location of the product label:
Start
Install/exchange battery(Picture A)
- Open the battery cover
- Put the battery in it correctly
- Close the battery cover
It should be exchange the battery when the LCD display the symbol
Use Alkaline battery
*Please take out the battery when you don’t use the meter for long time
Buttons(Picture B)
- Measurement button
- Volume/Area button
- Pythagorean theorem button
- Plus(+) button
- Record button
- Minus(-) button
- Datum button (The backlit keys)
- Cancel/power off button
- Unit exchange button
LCD display(Picture C)
-
Open the laser
-
Measure the datum edge(front)
-
Measure the datum edge(behind}
-
Multifunctional measurement
Area measurement
Volume measurement -
Use Pythagorean theorem to measure
-
Continuously measure
-
Battery level
-
Memory
-
The emission signal display
-
Signal strength indicator
-
The third display line
-
The second display line
-
The first display line
-
Result
The first operation and set
Power on and off
Power on meter and laser
Long press this button will power off, auto power off without operation for 3
minutes
Clear button, cancel the last instruction or clear the display. Press memory
button and clear button at the same time will clear all of records in the mode
of memory scanning.
The position of measuring reference edge(please see the diagram D)
The acquiescent reference edge of the instrument is the back porch.
keys: The multifunctional stand, the tripod hole, the leading edge and the
back porch will be chosen respectively as the measuring reference edges. When
you change the measuring reference edges, there will be different beeps to
remind you.
After restarting, the measuring reference edges will be back to the
acquiescent reference edge (back porch)
Backlit screen display:
Long press (t the key backlight lamp is switched on or off
The benchmark set
Short time press , a reference pre – or post How to set up the distance unit
of this instrument? Press the key to change the distance units until it
displays the units which you required: m, in, ft, ft+in.
| Distance| Area| Volume
---|---|---|---
1| 0.000 m| 0.000 m2| 0.000 m3
2| 01/16in| 0.000 ft2| 0.000 ft3
3| 0.000 ft| 0.000 ft2| 0.000 ft3
4| 0’00” 1/16| 0.000 ft2| 0.000 ft3
Measurement
A single distance measurement
Press key: turn the laser on. Press it again, measurement beginning. The
measuring data will be displayed on the screen promptly.
continuous measurement, Max/Min value will be displayed (please see the
diagram E)
continuous measurement can let the user to measure the max/min distance from
one measuring point. For example, measuring the Diagonal distance(max value)
of the room or the horizontal distance(Min value).
Press this key without moving until it appears beeps, that means the device enters into continuous measurement, Sweeping large area which around the measurement target by laser(ex: corner)
Press this key to stop continuous measurement. The corresponding max/min
values and the last measured data will be displayed on the main screen. The
instrument will exit the mode of continuous measurement automatically after
you continuously measured for 1000times.
Function
Plus/Minus
Distance measuring
Plus: Press one time, The first display line will be shining plus number.
The next measuring value will be plus the former one.
Minus: Press one time, The first display line will be shining minus number.
The next measuring value will be minus the former one.
The final step will be canceled.
Back to single distance measuring model,
Area of function
Press one time, icon will be display on the screen.
The button will move on the first distance . measuring(like length}.
Press again the button will move on the 2nd distance measuring(like width)
The area of the calculate result will be displayed on the main screen line. Very single measuring result will be display on the 2nd or third line
The function of volume.
Press 3 times, icon will be display on the screen
Press: move on the first distance measuring(like length)
Press: move on the second distance measuring(like width)
Press: move on the second distance measuring(like height)
The volume measuring result will be display on the main screen finally, previous 3 times result will be display on the first, second ,third aided line.
Indirect measuring
This model can be finished automatic calculation by the Pythagorean Law. This
function was designed aim at measuring the place where we can reach. For
example: view at the map the height of F, have to 2 times measuring.
The step is:
Press one time, icon will be display on the screen, the measured distance
will be shining on the screen.
button: measuring the right-angle side distance of triangle.
When measuring it, try to keep the device standard.
Button, measuring the bevel edge side distance of the triangle
If the measuring result meet the Pythagorean Law requirement(Bevel edge side
right-angle side) The height of indirect measuring will be display on the main line. The mid measuring value will be display on the second, third line separately.
Indirect measurement-use Pythagorean theorem two times to figure out the
distance lease see picture (G)
Press two times: Press two times , the sigh will show in the screen .the
distance will flicker in the screen.
key: to measure the down distance ,the first triangular hypotenuse. After
finish the measurement , it will indicate to measure triangular square edge
.keep the meter horizontal.
key: to measure the horizontal distance ,the public right angle for the two
triangles.
After finish the measurement , it will measure the next edge.
key : to measure the up distance ,the second triangular hypotenuse ..
If it fits for Pythagorean theorem .the height will show in the screen also
with those three measurements
Memory data
Hold key: the last measurement will show in the main screen ,and the 20 data
will show in inverted order . When scan, all measurements can be deleted by
press the data hold key.
Specifications reference
| 40| 60| 80| 100
---|---|---|---|---
Measure rang| 0.05-40m| I 0.05-60M| 0.05-80M| 0.05-100M
Measure accuracy| +1.5 mm
---|---
Measure unit| m/inch/ft
Laser level| Class II
Laser Type| 635 nm <1mW
Area ,volume| √
Pythagorean theorem| √
Add/deduct| √
Min/max measure| √
Continuous measure| √
Backlight| √
Several indications| √
Beep display| √
Waterproof| √
Memory data hold| 20
Laser point diameter| 8/ 40 mm
Located position| 110 I 60ml
Operating temperature| -10°C to 50°C /14°F to 122°F\
Storage temperature| -25°C to 70°C/-13°F to 158°F)
Power life| 5 000 times
Power| 2 x 1.5V AA
Automatically tum off the laser| 70s
Automatically cower off| 1omin
Size| 116 x 56 x 32 mm
Weight| 100g
Measure Terms
Range
The max measurement range 40/60/80/100meter.
When in less reflect light , please use sight vane .
The surface of the measured object It will make mistakes if the surface of the
object is liquid (water ) or clear transparent substance.
If the object has very strong reflected light ,the laser may be reflected ,and
it will make mistakes .
When measure no reflected or dark surface, it will increase the measuring time
Storage:
It’s forbidden to place the meter into water ,please use soft and damp cloth
to clean the meter ,don’t use corrosion or volatilization to clean it .
The fault causes and Solutions
Reason code
|
Solution
|
---|---|---
****| The calculation error| Repetitive operation
| The received signal is too weak, the measurement time is too long, more than
60 meters distance| The use of target
| Hardware failure| Such as in the open and closed after several instruments
still have the same problem, please contact your dealer.