Westinghouse W-762 Indoor Lighting Fixture Owner’s Manual
- June 3, 2024
- Westinghouse
Table of Contents
W-762 Indoor Lighting Fixture
Owner’s Manual
FIXTURE WARRANTY
This Westinghouse lighting fixture is warranted against defects in material
and workmanship for a period of five years from the purchase date. This
warranty is in lieu of all other warranties expressed or implied.
This warranty does not cover acts of nature such as lightning damage, or
corrosion and discoloration of components, nor does it cover damages caused
through abuse, improper installation, surges in electric current, or acts of
third parties.
This warranty does not cover the costs of removing and re-installing the
lighting fixture.
If this product fails for any reason covered by this warranty, please contact
us at www.westinghouselighting.com/contact-
us.
ASSEMBLY INSTRUCTIONS FOR INDOOR LIGHTING FIXTURE
Congratulations on your Westinghouse purchase. This fixture has been designed
to give you many years of beauty and service. For questions and comments,
please visit
www.westinghouselighting.comcontactus.
NOTE: Carefully
unpackwww.westinghouselighting.com contact
us
for fixtures and parts. Make sure all parts are included before discarding any
packing materials (see figure 1).
WARNING: ELECTRICAL SHOCK CAN RESULT IN SERIOUS INJURY.
Read and follow instructions exactly as shown. If instructions are unclear, do
not proceed. Contact a qualified electrician. Read all instructions before
beginning. Proper wiring is essential for the safe operation of this fixture.
When cutting or drilling into walls or ceilings, do not damage electrical
wiring, gas lines, or water lines. If any of the fixture or wiring components
are damaged, do not install the fixture. Return to the place of purchase.
For fixtures provided with 75° C or 90° C supply wire warning only. (These
warnings are provided on the U.L. label and on the fixture carton.) Risk of
fire. Most dwellings built before 1985 have supply wires rated 60° C. Consult
a qualified electrician before installing.
The line art shown may not exactly match the fixture enclosed. However, the
installation instructions do apply to this fixture.
MOUNTING AND WIRING INSTRUCTIONS
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.
- Turn off the power at the circuit box to avoid possible electric shock.
- Position the flat side of the mounting plate (C) against the wall at the mounting location and mark outer holes (T) with a pencil using the mounting plate’s outer holes (T) as a guide.
- Drill a 1/8 inch hole at each pencil mark then insert wall anchors (E) by gently tapping with a hammer.
- Thread outlet box wires through the center opening in the mounting plate (C).
- Position mounting plate (C) with outer holes (O) over wall anchors (E) and secure with screws (K) or secure mounting plate (C) to outlet box (J) with outlet box screws (P) (if applicable).
- Secure the fixture loop 1 (R1) to the nipple (L). Do not twist and kink wires.
- Open one link on the bottom end of the chain (F). Attach to fixture loop 1 (R1). Securely close link on chain (F).
- Lace wires up through every other link on chain (F) then through fixture loop 2 (R2) and face plate (A).
- Open one link on the top end of the chain (F). Attach to top on fixture loop 2 (R2). Securely close link on chain (F).
- Repeat steps 6 through 9 for the second fixture loop1 (R1) and chain (F).
- Secure the decorative frame (M) to fixture arms (N) with cap nuts (Q) and screws (U).
- Identify color coding of fixture wires.
- Connect the black wire from the fixture with the black wire (live wire) from the outlet box (J) by wire connector (G), and wrap the wire connector (G) with electrical tape for a more secure connection.
- Connect the white wire from the fixture with the white wire (neutral wire) from the outlet box (J) by wire connector (G), and wrap the wire connector (G) with electrical tape for a more secure connection.
- Partially thread green grounding screw (H) into side hole (I) on mounting plate (C) (see fig.1).
- Wrap the bare grounding wire from the fixture canopy around the green grounding screw stem (H) on the mounting bar leaving enough excess wire. Connect the greenish grounding wires from the hanging cord and excess grounding wire from the fixture canopy with the grounding wire from outlet box (J) by using a wire connector (G), then wrap the wire connector (G) with electrical tape for a more secure connection.
- Tuck wires inside the outlet box (J).
FIXTURE ASSEMBLY INSTRUCTIONS
Warning: This fixture is for indoor use only.
- Replace face plate (A) over the mounting plate (C) and secure it into place with hex nuts (S) (if applicable) and cap nuts (B).
- Install lamp(s). Do not exceed the recommended wattage.
- Turn the power back on at the circuit box.
WARNING
Turn off the electricity to the mounting site before beginning installation.
Mounting instructions must be followed exactly as shown for the fixture to be
safely supported.
CLEANING AND CARE
To clean, wipe the fixture with a soft cloth. Clean glass with mild soap.
Spraying from chemical cleaners can discolor the finish of the fixture. Do not
use scouring pads, powders, steel wool, or abrasive paper to clean this
fixture.
ORDERING PARTS
Keep this manual for future reference, and in case replacement parts are
needed. Available parts can be ordered from the place of purchase. Use exact
wording from diagrams when ordering parts.
Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A.
and Westinghouse is a trademark of Westinghouse Electric Corporation.
Used under license by Westinghouse Lighting.
All Rights Reserved.
www.westinghouselighting.com
Made in China
References
- Sustainable LED lighting solutions | Philips lighting
- Ceiling Fans | Lighting Fixtures | Lamps
- Contact Us
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>