GMLighting MDL-4HFL-HL-5CCT MicroTask4 High Lumen Recessed LED Downlight Installation Guide

June 1, 2024
GMLighting

GMLighting-LOGO

GMLighting MDL-4HFL-HL-5CCT MicroTask4 High Lumen Recessed LED Downlight

Specifications:

  • Product Model: Microtask High Output 120V Downlight
  • Models: MDL-4HFL-HL-5CCT, MDL-4HWFL-HL-5CCT (Fixture Housing)
  • Models: MDL-4R-TRSM-X, MDL-4S-TRSM-X, MDL-4R-TRST-X,MDL-4S-TRST-X (Trims)
  • Power: 120V
  • IC Rated Downlight
  • Color Temperature Options: 5 CCT options

Product Usage Instructions

Installation:
Before proceeding with the installation, engage a qualified and licensed electrician. Ensure all system parts are compatible and grounded according to electrical codes.

Select Color Temperature:
Choose one of the five color temperature options by using the selector switch on the front of the junction box.

Installation Preparation:

Remodel:
Determine the position of the downlight, trace a circle, and cut through the surface material. Install the power supply box at this point.

New Construction:

Use the new construction mounting plate for proper positioning.
Follow mounting instructions provided with the plate for correct aperture cut- out.

Connect Incoming Power:
Connect the power supply box to a 120V power source using flexible conduit or Romex. Connect incoming leads to the power supply input leads following color codes (Green to Ground, White to Neutral, Black to Hot Line).

Mount Junction Box and Plate:

Remodel Installation:
Secure the junction box in the ceiling space and feed it into the hole, leaving the quick connect cord accessible.

New Construction & Plate Installation:
Mount the power supply box to the new construction plate before installing it. Position the plate at the bottom of studs and cut out a hole for the downlight.

Assembling Fixture & Mounting Trim:
Select the appropriate housing option based on the model number provided.

FAQ:

Q: Can I install the downlight in areas with high ambient temperatures?
A: No, do not install in applications outside of the listed ambient temperature range.

Q: Is it necessary to hire an electrician for installation?
A: It is recommended to engage a qualified and licensed electrician for installation.

INSTALLATION INSTRUCTIONS
MICROTASK HIGH OUTPUT 120V DOWNLIGHT
MODELS: MDL-4HFL-HL-5CCT, MDL-4HWFL-HL-5CCT (FIXTURE HOUSING)
MDL-4R-TRSM-X, MDL-4S-TRSM-X, MDL-4R-TRST-X, MDL-4S-TRST-X (TRIMS)

WARNING!

BEFORE YOU START:

  • Please check local electrical codes before beginning
  • Turn power off before installing
  • Make sure to use properly rated wire

TOOLS NEEDED:

  • Hole saw or keyhole saw
  • Measuring Tape
  • Stud finder

PARTS INCLUDED:

  • Downlight housing and trim chosen seprately
  • Cut-out hole template
  • Wire connectors

INSTRUCTION

NOTE: WE RECOMMEND THAT YOU ENGAGE A QUALIFIED AND LICENSED ELECTRICIAN. ALL SYSTEM PARTS ARE COMPATIBLE WITH AND ONLY WORK TOGETHER. DO NOT ATTEMPT TO SWAP OUT OTHER MANUFACTURERS PRODUCTS. INSURE THAT BOTH WALL SWITCH AND WIRING COMPARTMENT IS GROUNDED IN ACCORDANCE WITH NEC OR LOCAL ELECTRICAL CODES.
DO NOT INSTALL IN AN APPLICATION THAT IS OUTSIDE OF THE PRODUCTS LISTED AMBIENT TEMPERATURE AND IN AN AREA THAT IS NOT EASILY ACCESSED FOR SERVICE REQUIREMENTS. DOWN LIGHT IS IC RATED.

  1. Familiarize yourself with the down light fixture model to be installed. Refer to Table (Fig. 1) for cutout hole size. 120V electrical power whip should be installed by a licensed electrician before proceeding. CAUTION: Space behind location of downlight must be clear of building materials and electrical components.

  2. SELECT COLOR TEMP:
    Select color temperature of light source. You’ll find the color temp. selector switch on the front of the junction box. You must choose one of five color temperatures before mounting the Power Supply Box (Fig. 4A).

  3. INSTALLATION PREP FOR REMODEL:
    Determine the position of your down light(s) and trace a circle on surface material. Using a keyhole saw or hole saw – cut through surface (Fig. 2). NOTE: It is easier to install the power supply box at this point. Go to Steps 4 and 5.1.

  4. INSTALLATION PREP FOR NEW CONSTRUCTION:
    Use UNV-NCP new construction mounting plate. Consult mounting instructions that come with this plate (Fig. 3). Be sure you use correct aperture cut-out (Fig. 1) to prepare the plate for use. New Construction Plate assists with position of hole location and Power Supply Box mount before drywall is installed. Do steps 4 and 5.2.

  5. CONNECT INCOMING POWER:
    Open Power Supply box cover and remove appropriate knock-outs to install fittings (1/2” trade size) with power leads. Connect Power Supply Box to 120V power source using flexible conduit or Romex (by others) through the mounting hole. Using wire connectors, connect incoming leads to power supply input leads. Ground to Green wire, Neutral to White wire, Hot Line to Black wire of box (Fig. 4A).
    MOUNT JUNCTION BOX AND PLATE INSTALL:

  6. REMODEL INSTALLATION:
    Secure junction box in ceiling space. Use keyhole slots on back of box to hang using two round head screw (by others). (Fig 4B). Proceed to feed junction box up into hole (Fig. 4C), leaving the quick connect cord hanging out of the trim hole for easy access. Go to Step 6 next.

  7. NEW CONSTRUCTION & PLATE INSTALL:
    Mount power supply box to New Construction Plate before installing plate (see locations in Fig. 3). Position plate at bottom of studs, where the downlight hole in the ceiling will be. Nail plate to studs and install drywall. Locate hole in plate with stud-finder and cut out hole to match plate. Pull the quick connect cord out of the trim hole for easy access.

  8. ASSEMBLING FIXTURE & MOUNTING TRIM:

SELECT HOUSING OPTION

CATALOG NO. BEAM
MDL-4HFL-HL-5CCT 38°
MDL-4HWFL-HL-5CCT 60°

SELECT TRIM OPTION

SMOOTH

CATALOG NO.| SHAPE| COLOR
MDL-4R-TRSM- BK| Round| Black
MDL-4R-TRSM- WH| Round| White
MDL-4S-TRSM- BK| Square| Black
MDL-4S-TRSM- WH| Square| White
STEPPED

CATALOG NO.| SHAPE| COLOR
MDL-4R-TRST-BK| Round| Black
MDL-4R-TRST-WH| Round| White
MDL-4S-TRST-BK| Square| Black
MDL-4S-TRST-WH| Square| White

There are several trim options for various applications. A housing and trim are required to complete the fixture. (Fig. 5). Take selected trim and align it with the light engine. Press and twist to tighten in place (Fig. 6)

CONNECT FIXTURE TRIM

Connect the quick connector by inserting and twisting the male/female connectors until tight (Fig. 7).

Depress torsion mounting springs, and push MDL-4H assembly up into hole (Fig. 8) letting the springs snap into place. Assure that trim is held firmly. Make final adjustments to trim position if needed.

FIG. 1

CUT-OUT DIMENSIONS/APPLICATIONS

CATALOG NO. PREFIX| HOLE DIA.| APPLICATION
MDL-4HFL-5CCT & MDL-4R or MDL-4S Trim| 3-3/4”| 38° beam spread
MDL-4WHFL-5CCT & MDL-4R or MDL-4S Trim| 3-3/4”| 60° beam spread

MAX SHEETROCK THICKNESS = 5/8”

GMLighting-MDL-4HFL-HL-5CCT-MicroTask4-High-Lumen-Recessed-LED-
Downlight-1

GMLighting-MDL-4HFL-HL-5CCT-MicroTask4-High-Lumen-Recessed-LED-
Downlight-2

©2024 GM LIGHTING, LLC • www.gmlighting.net • Specifications subject to change without notice
18700 Ridgeland Ave., Tinley Park, IL 60477 • Toll-Free: 866-671-0811 FAX: 708-478-2640[email protected]

MICROTASK_MDL-4HFL_MDL_4HWFL
INSTRUCTIONS_01.2024

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GMLighting User Manuals

Related Manuals