CE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power Station User Manual

June 1, 2024
CE-LINK

300W Power Station
portable Wi-FiCE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power
Station User Manual
Model: SR0KW3L-SG1-US, PS300-US, PW601-300,
XP2W300USCA, HWBG200

Parameters

General

Net weight ≈3.65kg (≈8lbs)
Dimension 248x164x150mm (9.7×6.4×5.9in)
Battery capacity 204.8Wh, 25.6V 8Ah
Wi-Fi supported

Output

(UK/EU/FR/AU/ZA)

AC socket (Inverter mode)| pure sine-wave, total 300W (peak 500W), 220-240V~, 50Hz/60Hz, 1.5A
AC socket (Bypass mode)| 220-240V~, 50Hz/60Hz, 300W Max., 1.5A

(US)

USB-A1/A2 5V 2.4A, 12W Max.
USB-C1/C2 5/9/12/15 3A, 20V 3.25A, 65W Max.
USB-C1+C2 5/9Vs23A, 12V 22.5A, 15Ve 2A, 20V2 1.5A, (OW Max.
Car charger 12.6V 8A, 100W Max.
  • Inverter mode: the output AC power comes from the battery, not the grid.
  • Bypass mode: the output AC power comes from the grid, not the battery.

Input
(UK/EU/FR/AU/ZA)

AC input power 550W Max., 3V
AC input voltage 220-240V 50Hz/60Hz

(US)

AC input power 550W Max 6A
AC input voltage 220- 240 50Hz/60Hz
PV charge 120W Max 12-24 8A
--- ---
Car charging input 12V battery supported, 8A by default

Input charging

AC charging power 250W Max.
PV charging input 120W Max.
Car charging input 96W Max.
AC+PV charging power 250W Max.

Battery

Cell Type lithium iron phosphate battery (LiFePO4)
Life cycle 3000 cycles
Protection type over temperature protection, low temperature protection,

over discharge protection, over charge protection, over load
protection, short circuit protection, over current protection

*Test conditions:95% DOD, 0.5C charge & 0.5C discharge at +25±3℃.

Operating temperature

 Optimal operating temperature 20°C-30°C (68°F-86°F)
Discharge temperature range -20°C-45°C (-4°F-113°F)
Charge temperature range 0°C-45°C (32°F-113°F)
Storage ambient temperature -20°C-45°C (20°C-30°C preferred)

[-4°F-113°F(68°F-86°F preferred)]

Safety guidelines

2.1 Warning

  1. Do not let a working power station be close to the heat source, such as fire or heater.
  2. Do not make power station contact with any liquid.
  3. Do not use power station in a strong electrostatic or strong magnetic field environment.
  4. Do not disassemble power station in any way or pierce it with a sharp object.
  5. Do not short power station by wire or other metal objects.
  6. It is forbidden to step on, sit or climb on this product.
  7. Do not use ingenuine parts or accessories. For part or accessory replacement, please visit official sales channel for purchase information.
  8. When using power station, please follow the operating temperature defined in this user manual strictly. If the temperature is too high, battery may catch fire or even explode. If the temperature is too low, power station performance will be seriously  impaired, even normal use will be impacted.
  9. Do not stack heavy objects on power station.
  10. Do not stop the fan by force or expose power station in an unventilated or dusty environment when it is working.
  11. Please avoid collision, drop, and violent vibration. If severe impact happens, shut down the power supply immediately. Please fix power station firmly during transportation to avoid vibration and impact.
  12. If power station falls into water accidentally, place it in a safe and wide area, and keep yourself away from it until it’s dry. Dried product shall not be used again. Dispose it properly according to chapter 2.2 in this user manual. If power station is on fire,  please use fire extinguishing equipment in the recommended order: water or water mist, sand, fire blanket, dry powder, dioxide carbon fire extinguisher.
  13. If there is dirt, use a dry cloth to wipe it.
  14. Place power station carefully to prevent damage. If power station is tipped over and seriously damaged, turn off power station immediately and place the battery in a spacious place and keep it away from flammable materials and people, and scrap it in accordance with the requirements of local laws and regulations.
  15. Keep power station out of the reach of children and pets.
  16. Keep power station in a dry and ventilated place.
  17. In humid environment (seaside, water, etc.), it is recommended to equip power station with moisture-proof bag. If water is found inside product, do not use/start it again. Please take countermeasures to prevent electric shock before touching power station. Put it in a safe and waterproof open area, and contact customer service immediately.
  18. It is not recommended to use power station to supply power for safety-related emergency medical equipment, including but not limited to medical grade breathing machine (hospital version CPAP: Continuous Positive Airway Pressure), artificial lung  (ECMO, Extracorporeal Membrane Oxygenation). It can be used to supply power for home version CPAP at home and does not require continuous professional monitoring. Please follow your doctor’s advice and consult the manufacturer for any  restrictions on the use of the device. For general medical equipment, please pay attention to the power condition to ensure that power does not run out.
  19. Power supplies will inevitably generate electromagnetic fields when it is in use, which might affect the implantable medical device or normal operation of personal medical device, such as pacemaker devices, cochlear implants, hearing AIDS, defibrillators,  etc. If any of these medical devices are used, please consult the manufacturer about the restrictions on the use to ensure that power station is operated at a safe distance from implanted medical devices such as pacemakers, cochlear implants, hearing AIDS,  defibrillators, etc.
  20. When the power station is connected to a refrigerator, it may automatically shut down because of the power fluctuation property of the refrigerator. When connecting the power supply to a refrigerator that stores medicine, vaccines or other valuable items,  it is recommended to set the AC output to “Never off” in the APP, so as to ensure continuous power. Users should pay attention to power consumption.
  21. During the push-pull movement of this product, it is forbidden to put other items on this product.

2.2 Discard

  1. Conditions permitting, be sure to discharge the battery completely, and then put power station in the specified battery recycling bin. Power station contains batteries, which are dangerous. It is strictly prohibited to discard them in ordinary dust bins. For
    details, follow local laws and regulations on battery recycling and disposal.

  2. If the battery cannot be discharged completely due to product failure, do not discard the battery directly in the battery recycling bin. Contact a professional battery recycling company for further disposal.

  3. The battery will not start after over discharge. Please dispose it as discarded.

Guideline for users

3.1 Product overview

CE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power Station - Product
overviewCE-LINK SR0KW3L-SG1-US
Portable Wi-Fi Power Station - Product overview 2

3.2 LCD screen

CE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power Station - LCD
screen

Battery capacity: When power station is being charged, SOC icon will flicker.
Wi-Fi connection status: When wifi reset, wifi icon will flash for 3s, wifi icon light up when wifi link, wifi icon go out when wifi disconnect.
Bluetooth connection status: The Bluetooth icon lights up when this product is matched wirelessly. The Bluetooth icon lights up when the Bluetooth link is successful. Bluetooth icon goes out when Bluetooth is disconnected.

  • Please refer to clause for more details regarding error message.

3.3 Use

CE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power Station -
Use

On and off

  • Press the main power switch to turn on the device, then the screen will be lit and the main power indicator light will light up.

  • When this product lasts for 5 minutes without any operation, the LCD display will be automatically extinguished.

  • When this product is plugged in and unplugged from mains, pv, car charger or key operation, the LCD display will be lit up automatically. To turn on or off the LCD display, press the main power switch.

  • Press and hold the main power switch will turn off power station.

  • In the normal mode (the power is above 5%), the default standby time of this product is 2 hours; when the AC output switch is not turned on, and there is no charge or discharge for 5 hours, the product will automatically shut down, and the standby time  can be Set it on the APP; when the power is 5% or below, the product will be forced to enter the low power mode. In the case of no charge or discharge, the product will adjust the standby
    time according to the power and automatically shut down.

  • In normal mode, long press the LED light button to exit the automatic shutdown setting, and the battery icon on the screen will flash. Long press again to enter the automatic shutdown setting, and the battery icon does not flash. (The automatic shutdown  setting is to protect the battery from low power, exiting this setting may damage the battery life, please use it with caution.)

CE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power Station - LED
lights

Note: When no AC input, long press the above AC output button, you can switch the AC off-grid output frequency ( ), long press 5s to switch, the AC output icon will flash times after successful switching.

  • The 12V DC output is turned on by default when the main power supply is turned on.
    CE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power Station -
output

AC output

  • After ensuring that the main power is turned on, short press the AC output power switch to turn on the AC output. Short press the AC output power switch again to turn it off.
  • The default standby time of the AC output port is 1 hour. After 1 hour without any load on the AC output port of this product, the AC output power will be automatically turned off. In normal mode, long press the LED light button, the AC output power  switch can exit the automatic shutdown setting, and the battery icon on the screen will flash. Long press again, the AC output power switch enters the automatic shutdown setting, and the battery icon does not flash.
  • Long press the LED light button to exit the AC automatic shutdown setting: it is applicable to AC equipment below W and pulse working equipment.
  • When the AC output is not in use, turn it off to save power consumption.

3.4 AC charging
When the product is turned on, the default fast charging mode is working. If your product has a wifi function, you can control the recharge rate through the APP.CE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power Station - AC
charging

Please use the standard AC cable for charging. AC charging cable should directly plug into 10A (or above) wall-mounted socket. We take no responsibilities for any damage caused by using unofficial AC charging cable, and other failures to follow instructions.

3.5 PV charging

*Solar charging cable (DC 7909)

  • Please follow the user manual to connect the solar panels.
  • Before connecting the solar panel, check whether its output voltage is within power station specifications to avoid damage to power station.
    *The interface of this product is DC7909. If you need an adapter cable from MC4 to DC7909, please purchase it yourself.
    CE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power Station - PV
chargingCharge the power station by solar panel.

3.6 Car charging

CE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power Station - Car
charging

*Car charger cable (DC7909)
Power station can be charged by a car charging port. It should be charged after the car starts, so as to avoid the car battery loss and failure to start. At the same time, ensure good connection between the car charging port and cigarette lighter. We take no  responsibilities for any loss caused by improper operation.

3.7 Constant power

  1. The constant power output function is enabled by default, which can be turned on or off by App.
  2. Constant power output function is more suitable for heater and motor instead of all electrical equipment. It is not suitable for some electrical appliances with voltage protection (such as precision instruments). Constant power output function application is  subject to actual testing.

3.8 APP
You can control and view information and data about this product by App.
Software download, search for [Smart Life] in the Google App Store or Apple App Store, download the software, register and open it or scan the QR code below to download. For detailed usage of the APP, please refer to the APP Operation Guide.

https://smartapp.tuya.com/smartlife

3.9 EPS function
This product supports the EPS (emergency backup power) function. You connect the power grid and the AC input port of this product through the AC charging cable; Bypass mode (AC power comes from the grid, not the battery); when the grid suddenly loses power, the product can automatically switch to battery power supply mode within 10mS, at this time it is an inverter mode (AC power comes from the battery, not the grid). This function does not support 10mS switching. Please do not connect it to devices that require high uninterrupted power supply, such as data servers and workstations, or use it after multiple tests to confirm whether it is compatible, and It is recommended to use only one device during use, and do not use multiple devices at the same time to avoid overload protection of the product. If the device does not operate normally or data is lost due to failure to follow the instructions, our company will not bear the corresponding responsibility. CE-LINK SR0KW3L-
SG1-US Portable Wi-Fi Power Station - EPS function

FAQs (Frequently Asked Questions)

  1. What kind of battery is used?
    Lithium iron phosphate battery (LiFePO4).

  2. What equipment can be connected to the AC output ports?
    The AC output port of the product has high rated power and the highest power, which can supply power for small power household equipment. We suggest confirming the power of the equipment before use to ensure that the sum of the power of all load  equipment is lower than the rated power.

  3. How to know the supply time?
    Time shows in the LCD, which can be referred to for estimation for equipment with stable power consumption.

  4. How to know it is charging?
    When in charge, the LCD shows remaining charging time. The SOC flickers, and input power is shown.

  5. How to clean the unit?
    Clean the unit with a dry, soft and clean cloth or tissue.

  6. How to store the unit?
    Turn it off, and keep it in a dry and ventilated place. Do not expose it close to water. For long-term storage, suggest discharge to 0% and charge to 100% every 3 months to extend the service life.

  7. Can it be taken on board?
    No.

Error messages & solutions

Icon Fault Description Solution
Error code always on Pressure difference
is too large Automatic recovery after fault clearing; 3 consecutive locks

within a certain period of time, longer recovery time.
Error code always on| Battery OTP (over  temperature protection) fault| Shut down, after temperature recovery, rechargeable activation.
Error code always on| Battery UTP (under  temperature protection) fault
Error code always on| OCP (over current protection) fault| Remove the over- power device, and it will automatically recover  after the fault is cleared; if it is triggered continuously for 3 times  within 1 minute, it will be locked, and the recovery time will be  prolonged, and it can be recovered by powering on and off again.
Error code always on| Abnormal precharge| Power on and off again to clear the fault.
Error code always on| Battery under voltage fault| charging process, Repeated charging failures or failure to charge,
please contact customer service.
Error code always on| Abnormal INV battery voltage| Automatic recovery after the fault is cleared; if it is triggered 3 times within 1 minute, it will be locked, and the recovery time will be extended, and it can be recovered by powering on and
off again.
Error code always on| Grid voltage or frequency fault| The fault is cleared when the grid returns to normal.
Error code always on| Abnormal INV BUS voltage| Automatic recovery after the fault is cleared; if it is triggered 3  times within 1minute, it will be locked,
and the recovery time will be extended, and it can be recovered
by powering on and off again.
Error code always on| Abnormal INV output
Error code always on| INV discharge overload| Remove the over-power device, and it will automatically recover  after the fault is cleared; if it is triggered continuously for 3 times  within 1 minute, it will be locked, and the recovery time will be prolonged, and it can be recovered by powering on and off again.
Error code always on| Charge overload| Automatic recovery after the fault is cleared; if it is triggered 3  times within 1 minute, it will be locked, and the recovery time will  be extended, and it can be recovered by powering on and off  again.
Error code always on| INV Tz| Auto recover after fault is cleared.
---|---|---
Error code always on| INV output short| Fault will be cleared after reboot.
Error code always on| MOSFET OTP fault| After removing the device and restarting, the fault is cleared.
Error code always on| Fan stop| Exclude the fan abnormality, turn on and off, contact after sales if still not  fixed.
Error code always on| e soft Discharge start fault| Auto recover after fault is cleared.
Error code always on| Charge soft start fault| Automatic recovery after the fault is cleared; if it is triggered 3 times within 1  minute, it will be locked, and the recovery time will be extended, and it can be
recovered by powering on and off again.
Error code always on| MOSFET UTP fault| Automatic recovery after the product heats up.
Error code always on| PV hardware OCP fault| Remove PV charge, auto recover after connecting PV and turn on.
Error code always on| PV1 software OCP fault| Stop PV1 charging, auto recover after connecting PV and turn on.
Error code always on| Car charger output/DC5521  output Over current protection| Turn off output, manual recover after fault is cleared.
Error code always on| PV output OVP (over voltage protection) fault| Removing the PV charging interface will automatically restore it after a  certain period of time.
Error code always on| PV1 input voltage over-voltage protection| Remove the PV charging interface for a certain period of time to  automatically recover or check whether the PV output fuse is disconnected.
Error code always on| PV1 OTP fault| Stop PV1. Auto recover after fault is cleared.
Error code always on| Abnormal communication| Turn on and off, or change operation environment.
Contact after sales if still not fixed.
Error code always on| The battery voltage is too low.
The battery is broken| Contact after-sales processing.

If none of the above information can solve problem you encounter, please contact the customer service for consultation.

What’s in the box

CE-LINK SR0KW3L-SG1-US Portable Wi-Fi Power Station - in the
box

Maintenance

  • It is recommended to use or store power station under 20~30°C ambient temperature. Keep it away from water, heater and metal parts.
  • For long-term storage, charge and discharge every 3 months, i.e. discharge to 0% then charge to 100%.
  • For safety, do not store power station with temperature above 45°C or below -10°C.
  • If the capacity is lower than 1%, please charge to 60%. Long-term storage with serious power shortage will cause irreversible damage to the cell and shorten the service life of the product.
  • If the capacity is seriously insufficient and idle time is too long, the product will enter deep sleep mode, and the product can only be used after being charged.

Disclaimer

  • The product has a built-in battery management system, which has protections such as overcharge, overdischarge, overcurrent, short circuit, high and low temperature, and abnormal communication. During the use of this product, protection may occur and cause output interruption. Power supply to special equipment, such as medical equipment, server, the indirect loss caused by accidental power failure has nothing to do with the company; all accidents caused by illegal use, self-dismantling, and man-made  damage have nothing to do with the company.
  • Before using the power station power station, please read this user manual to ensure understanding and proper use. After reading the user manual, please keep it well for future reference. Improper operation may cause serious injury to yourself or others,  or result in product damage and property loss. Once using power station, you are deemed to have understood and accepted all terms and contents herein. Users promise to be responsible for their actions and all consequences arising therefrom. We shall  not be liable for any loss arising from user’ s not following this user manual.
  • In compliance with laws and regulations, the company reserves the right of final interpretation of this document and all related documents of this product. Subject to update, revision or termination without prior notice, please visit the official website for the latest product information.

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference. (2)This device must accept any interference received, including interference that may cause undesired  operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note:This equipment has been tested and found to comply with the limits for a class B digital device,pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequence energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in  a particular installation. If this equipmemt does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following  measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an autlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The device has been evaluated to meet general RF exposure requirement, This equipment should be installed and operated with a minumum distance of 20cm between the radiator and your body.
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
This device may not cause interference.
This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals