Mr Heater MHVFRD10LP LP-Gas Fired Room Heater Owner’s Manual

June 5, 2024
MR Heater

Mr Heater MHVFRD10LP LP-Gas Fired Room Heater [

Mr Heater MHVFRD10LP LP-
Gas Fired Room Heater product](https://manuals.plus/wp-content/uploads/2022/07/Mr-Heater- MHVFRD10LP-LP-Gas-Fired-Room-Heater-product.png)

INSTRUCTIONS

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • WHAT TO DO IF YOU SMELL GAS
    • Do not try to light any appliance.
    • Do not touch any electrical switch; do not use any phone in your building.
    • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
    • If you cannot reach your gas supplier, call the fire department.
  • Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for Combustion and Ventilation section on page 4 of this manual.
This appliance may be installed in an aftermarket permanently manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with any other gas.

WARNING: FIRE, EXPLOSION, AND ASPHYXIATION HAZARD
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or gas supplier.
Read and follow instructions and precautions in User’s Information Manual provided with this heater.

DANGER

HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.
WARNING: This appliance is equipped for propane gas. Field conversion is not permitted.
WARN ING: THIS PRODUCT CAN EXPOSE YOU TO CHEMICALS INCLUDING LEAD AND LEAD COMPOUNDS, WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. FOR MORE INFORMATION VISIT WWW. P65WARNINGS.CA.GOV
WARNING: Fuels used in liquefied propane gas appliances, and the products of combustion of such fuel, can expose you to chemicals including benzene, which is known to the state of California to cause cancer and cause birth defects or other reproductive harm, for more information go to www.P65Warnings.ca.gov

  • Due to high temperatures, heater should be kept out of traffic and away from furniture and draperies.
  • Do not place clothing or other flammable material on or near the appliance.
  • Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.
  • Young children should be carefully supervised when they are in the same room with heater.
  • A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
  • Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater.
  • Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.

CAUTION: Never connect heater directly to the Propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and Propane/LP supply.
The installer must supply an external regulator. The external regulator will reduce the incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure heater regulator damage could occur. Install external regulator with the vent pointing down. Pointing the vent down protects it from freezing rain or sleet.

SOCIAL MEDIA
In order to provide the best service possible Mr. Heater is now giving you more ways to get in touch with us:
WEBSITE: Mr. Heater’s full line of product are now at: www.mrheater.com

SPECIFICATIONS [

Mr Heater MHVFRD10LP LP-Gas Fired Room Heater FIG
15](https://manuals.plus/wp- content/uploads/2022/07/Mr-Heater-MHVFRD10LP-LP-Gas-Fired-Room-Heater- FIG-15.png)

Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.**

PRECAUTIONS

  1. Either of the 10,000 BTU (2931 W) units (the MHVFRD10LP or the MHVFBF10LP) may be installed in a bedroom, but shall not be installed in a bathroom or any place where a strong wind would shut down the appliance.
  2. This heater needs outside ventilation air to run properly. The Oxygen Depletion Sensor (ODS) safety shutoff system shuts down the heater if not enough fresh air is available. See Fresh Air for Combustion and Ventilation, page 4.
  3. Keep all air openings in heater clear, free of debris or any blockage. This will ensure that enough air for proper combustion enters the heater.
  4. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, it requires servicing.
  5.  Turn off and let cool before servicing. Only a qualified service person should service and repair heater.
  6. Do not run heater:
    • Where flammable liquids or vapors are used or stored
    • During dusty conditions.
  7. Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.
  8. Do not use heater if any part has been underwater. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been underwater.
  9. Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.
  10. Always run heater with control knob in a locked position. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result if control knob is left between locked positions.

DANGER: Carbon monoxide poisoning may lead to death.

Carbon Monoxide Poisoning:

Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas:

Propane/LP gas is odorless. An odor making agent is added to propane/LP gas. The odor helps you detect a Propane/LP gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

Product FeaturesMr Heater MHVFRD10LP LP-Gas Fired Room Heater fig
1

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sensor
(ODS) safety shut off system. The ODS/pilot shuts off the heater if there is not enough fresh air.

IGNITION SYSTEM
PIEZO: The heater is equipped with a piezo manual ignitor. This system requires no matches, batteries, or other source to light heater.

LOCAL CODES
Install and use heater with care.
Installation must conform to local codes or in the absences of local codes, use the latest edition of National Fuel Gas Code, ANSI Z223.1/NFPA 54.

UNPACKING

  1. Remove heater from carton.
  2. Remove all protective packaging applied to heater for shipment.
  3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

FRESH AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

ESTABLISHING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, NFPA 54/ ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications:

  1. Unusually Tight Construction
  2. Unconfined Space
  3. Confined Space

This heater must not be installed in a confined space
or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The information on pages 4 and 5 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

If your home meets all of the three following criteria you must provide additional fresh air. See Ventilation from Outdoors, page 5.
Unusually tight construction is defined as construction where:

  • Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and
  • Weather stripping has been added on operable windows and doors, and
  • Caulking or sealants are applied to areas such as joints around windows and door frames, between wall­ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If you home does not meet all of the three criteria above, see Determining the Type of Heater Location Space, below.

Confined Space and Unconfined Space

The National Fuel Gas Code, NFPA 54/ ANSI 2223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the aggregate input rating of all appliances installed in that space, and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

  • Adjoining rooms are communication only if there are doorless passageways or ventilation grills between them.

DETERMINING THE TYPE OF HEATER LOCATION SPACE:

Use this method to determine if you have a confined or unconfined space.
Note: the space includes the room in which you install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

  1. Find the volume of the space by multiplying room length x width x height.
    Example: Space size 18ft (length) x 18ft. (width) x 8ft.
    (height)= 2592
    If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

  2. Divide the space volume by 50 cubic feet to determine the maximum Btu/hr the space can support.
    Example: 2592 cu.ft. (volume of space)/ 50 cu.ft. =  51.8 or 51,800 (maximum Btu/hr the space can support)
    WARNING: This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes

  3. Add the Btu/hr of all the fuel-burning appliances in the space such as, Vent-free heater, Gas water heater, Gas furnace, Vented gas heater, Gas fireplace logs, and Other gas appliances*

  • Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
    Example:
    Gas water heater: 40,000 Btu/hr
    Vent Free Heater +: 20,000 Btu/hr
    Total: =60,000 Btu/h

    1. Compare the maximum Btu/hr the space can support with the actual amount of Btu/hr used.
      Example: 51,800 Btu/hr (maximum Btu/hr the space can support) 60,000 Btu/hr (Actual amount of Btu/hr used)
      The space in the above example is a confined space because the actual Btu/hr used is more than the maximum Btu/hr the space can support.

You must provide additional fresh air. Your options are as follows:

  1. Rework worksheet, and the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between the rooms. See Ventilation From Inside Building (Fig. 2)Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 2
  2. Vent room directly to the outdoors. See Ventilation From Outdoors (Fig. 3).Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 3
  3. Install a lower Btu/hr heater if lower Btu/hr size makes room unconfined.
    If actual Btu/hr used is less than the maximum Btu/ hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

VENTILATION AIR

Ventilation from Inside Building
This fresh air would come from an adjoining unconfined space. When ventilation to an adjoining unconfined space, you must provide two permanent openings: one within 12″ of the ceiling and one within 12″ of the floor on the wall connecting the two spaces (see options 1 & 2 of figure 2). You can also remove door into adjoining room (see option3, fig 2). Follow the National Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined space must have enough fresh air to supply all appliance in both spaces.

Ventilation from Outdoors
If necessary provide extra fresh air by using ventilation grills or ducts. Connect these items directly to the outdoors or spaces open to the outdoors. These include attics* and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet into attic. If attic has a thermostat-controlled power vent, heated air entering the attic will activate the power vent.
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Fresh Air for Combustion and Ventilation, pages 4 through 5.

INSTALLATION

WARNING: Any change to this heater or its controls can be dan erous.
NOTICE: This heater is intended for the use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source for the duration of the outage.
WARNING: A qualified service person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only LP-gas. If your gas supply is not LP-gas, do not install heater. Call dealer where you bought heater for proper type heater.

THIS INSTALLATION REQUIRES:
Before installing heater, make sure you have the items listed below:

  • Piping (check local codes)
  • Sealant (resistant to LP _Gas)
  • Equipment shutoff valve*
  • Ground joint union
  • Test gauge connection*
  • Sediment trap
  • Tee joint
  • Pipe wrench

*A CSA/AGA certified equipment shutoff valve with 1/8″ NPT tap is an acceptable alternative to test gauge connection. Purchase a CSA/ AGA certified equipment shutoff valve from your dealer.

LOCATING HEATER
This heater is designed to be mounted on the wall. The heater can also be located on a non-combustible floor, away from a wall by using the floor mounting stands included with the heater. If installed on combustible flooring such as carpeting, tile or other combustible material other than wood flooring, the heater must be placed on a metal or wood panel extending the full width and depth of the appliance. Mr Heater MHVFRD10LP LP-Gas Fired
Room Heater fig 4

For convenience and efficiency, install the heater:

  • Where there is easy access for operation, inspection, and service.

  • In the coldest part of the room.
    CAUTION: If you install the heater in a home garage:

  • Heater pilot and burner must be at least 18 inches above floor.

  • Locate heater where moving vehicle will not hit it.

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall covering or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) are present in the air may discolor walls .
WARNING: Never install the heater:

  • In a recreational vehicle.
  • Where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater.
  • As a fireplace insert
  • In high-traffic areas
  • In windy or drafty areas

WARNING: Heater must be mounted to maintain the minimum clearances shown in Figure 4. If possible, provide greater clearances from the floor, ceiling, and joining walls.

FASTENING HEATER TO WALL

Mounting Bracket

The mounting bracket in located on the back panel of heater (see figure 5). It has been taped there for shipping. Remove mountin bracket from back panel. Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 5

Removing Front Panel of Heater

  1. Remove (4) screws total there are (2) screws on either side of the heater. (Figure 6)
  2. Pull the front panel and back panel apart. Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 6

Attaching Mounting Bracket to Wall

Use holes on each end of mounting bracket to attach bracket to wall. These holes are 16 inches apart. Attach mounting bracket to wall in one of two following ways.

  1. Attach to wall studs
  2. Attach to wall anchor

Attaching to Wall Stud:
This way is the best providing the strongest mounting in wood frame houses.

Attaching to Wall Anchor:
This way allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).
Decide which way best suits your needs. Either method will provide a secure hold for the mounting bracket.

  1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level. For wall stud mounting locate one end of the mounting bracket over a wall stud.
    WARNING: Maintain minimum clearances shown in fig­ure 7. If you can, provide greater clearances from the floor and joining wall.

  2. Mark screw locations on wall (see figure 7).

  3. Remove tape and mount bracket from wall. Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 7

Attaching to Wall Stud:
For attaching mounting bracket to wall studs

  1. Drill holes at marked locations using 9/64″ drill bit.
  2. Place mounting bracket onto wall. Line up holes on each end of bracket with hole drilled in wall.
  3. Insert mounting screws through bracket and into wall studs.
  4. Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to Wall using Anchor:
For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)
Note: Wall anchors, mounting screws, and spacer are in hardware package. The hardware package is provided with heater.

  1. Drill holes at marked locations using 5/16″ drill bit. For solid walls (concrete or masonry), drill at least 1″ deep.
  2. Fold wall anchor as shown in figure 8 below.
  3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.
  4. For thin walls (1/2″ or less) insert red key into wall anchor.
  5. Place mounting bracket onto wall. Line up holes on each end of bracket with wall anchors.
  6. Insert mounting screws through bracket and into wall anchors.
  7. Tighten screws until mounting bracket is firmly fastened to wall.

Placing Heater on Mounting Bracket

  1. Locate two horizontal slots on back pane of heater (see figure 9).
  2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 9

Installing Bottom Mounting Screws

  1. Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see figure 10). Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 10
  2. Mark screws locations on wall.
  3. Remove heater from mounting bracket.
  4. If installing bottom mounting screw into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching to Wall using Anchor. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64″ drill bit.
  5. Replace heater onto mounting bracket.
  6. Place spacers between bottom mounting holes and wall anchor or drilled hole.
  7. Hold spacer in place with one hand. With the other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.
  8. Tighten both screws until heater is firmly secured to wall. Do not over tighten.
    Note: Do not re-place front panel at this time. Replace front panel after making gas connections and checking for leaks.

FLOOR MOUNTING AWAY FROM WALL

Installing Support Feet (See figure 11.)

  1. Lay heater onto table on its back with bottom edge overhanging table edge.
  2. Securely attach feet to bottom of heater using 2 – self-tapping screws each. Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 11Note: Feet should have long end going out the front of heater, and the edge coinciding with side of heater. If feet overhang side of the heater, switch leg location.
  3. Place heater on non-combustible surface (see Locating Heater, page 6) before proceeding with gas connection. If this will be a permanent location, heater may be locked into position using anchoring holes in mounting feet.
    Note: Use of floor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection.

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
WARNING: This appliance requires a 3/8″ NPT (National Pipe Thread) inlet connection to the pressure regulator. Use of floor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection.

CAUTION: Never connect heater directly to the Propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and Propane/LP supply.
The installer must supply an external regulator. The external regulator will reduce the incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure heater regulator damage could occur. Install external regulator with the vent pointing down. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new black iron or steel pipe. Internally­tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.
Installation must include an equipment shutoff valve, union and plugged 1/8″ NPT tap. Locate NPT tap within reach of test gauge hookup. NPT tap must be upstream from heater (see figure 12).

  • A CSA/ AGA certified equipment shutoff valve with 1 /8″ N PT tap is an acceptable alternative to test gauge connection. Purchase the CSA/ AGA certified equipment shutoff valve from your dealer.

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater fuel train.

CAUTION: Use pipe joint sealant that is resistant to LP­Gas.

Install sediment trap in supply line as shown in figure 12. Locate sediment trap where it is within reach for cleaning. A sediment trap traps moisture and contaminants. This keeps them from going into heater. If sediment trap is not installed or is installed improperly, heater may not run correctly.

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig
12

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at  once.
WARNING: Never use an open flame to check for a gas leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM High Pressure
Test pressure in Excess of½ psig (3.5kPa)

  1. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of½ psi (3.5 kPa).
  2. Cap off open end of gas pipe where equipment shutoff valve was connected.
  3. Pressurize supply piping system by either using compressed air or opening the propane/LP supply tank valve.
  4. Check all connections and joints in gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
  5. Correct all leaks at once.
  6. Depressurize and relieve pressure in supply piping system.
  7. Reconnect heater and equipment shutoff valve to gas supply.
  8. Reconnected fittings must be checked for leaks in next section.

Low Pressure
Test Pressure Equal To or Less Than ½ psig (3.5 kPa)

  1. The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than½ psi (3.5 kPa). (see figure 13).
  2. Pressurize supply piping system by either using compressed air or opening propane/LP supply valve.
  3. Check all joints from the propane/LP supply valve to equipment shutoff valve (see figure 14. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
  4. Correct all leaks at once.
  5. Depressurize and relieve pressure from supply piping system.

Pressure Testing Heater Gas Connections:

  1. Make sure that the heater supply piping system is connected and has been leak tested as described above.
  2. Make sure control knob of heater is in OFF position.
  3. Open equipment shutoff valve (see figure 13).Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 13
  4. Open propane/LP supply valve.
  5. Check all joints from equipment shutoff valve to control valve (see figure 14). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
  6. Correct all leaks at once.
  7. Light heater (see Operating Your Heater, page 10). Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 14
  8. Turn off heater (see To Turn OFF Gas to Appliance, page 10.)
  9. Replace lower front panel.

OPERATING YOUR HEATER

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

  • This appliance has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

  1. Shut off gas supply.
  2. Do not try to light any appliance.
  3. Do not touch any electrical switch; do not use any phone in your building.
  4. Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  5. If you can not reach your gas supplier, call the fire department.
  • Use only your hand to push in or turn the gas control knob. Never use tools. If knob will not push in or turn by hand, don’t try to repair it; call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.
  • Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water.

LIGHTING INSTRUCTIONS

  1. STOP! Read the all safety information included with and on the side of heater.

  2. Check that gas supply to heater is on.

  3. Push in gas control knob and slightly turn clockwise, to the OFF position (see figure 16).
    Note: Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly. Do not force.

  4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!Follow “B” in the safety information above. If you do not smell gas, go to the next step.

  5. Push in gas control know slightly and turn counterclockwise to PILOT/IGN and depress for five (5) seconds.
    Note: The first time that the heater is operated after connecting the gas supply, the control knob should be depressed for about 30 seconds. This will allow air to bleed from the gas system.

  6. Push in control knob and rotate control knob back to OFF position then rotate counterclockwise to PILOT/IGN position. This will light pilot. If needed gently keep rotating control knob back and forth while depressed until pilot lights.

  7. Keep control knob depressed in for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 4, 5, 6 and 7.
    If pilot does not stay lit, refer to Troubleshooting, pages 12-13. Also, contact a qualified service person or gas supplier for repairs.
    If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

  8. FOR MHVFRD10LP:

    • Turn control knob to “HI” to light heater. Leave on “HI” position until the tiles have turned bright orange.

    • After the burner tiles have turned bright orange, adjust heat output by turning Control Knob to desired position (“LO” or “HI”).
      FOR MHVFBF10LP:

    • When the pilot is lit, turn the control knob to “HI” position to light.

    • After flame is established on “HI”, adjust heat output by turning control knob to desired position (“LO” or “HI”). Do not o erate heater between locked positions. Mr Heater MHVFRD10LP LP-Gas Fired Room Heater FIG 16

CAUTION: Do not try to adjust heating level by using equipment shutoff valve.
WARNING: When running heater, set control knob at “LO” or “HI” locked positions. Poor combustion and higher levels of carbon monoxide may result if heater is operated with control knob positioned between locked positions.

IMPORTANT: Release downward pressure while turning control knob. Control knob must be locked at the desired position.

TO TURN OFF GAS TO APPLI ANCE
SHUTTING OFF HEATER:

  1. Turn off the equipment shutoff valve.
  2. Turn control knob clockwise , to the OFF position.

SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)

  1. Turn control knob clockwise,_ to the PILOT/IGN position.

INSPECTING BURNER
Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 17 show a correct pilot flame pattern and also shows an incorrect pilot flame pattern. The incorrect pilot flame pattern is not touching thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 17:

  • Turn heater off (see To Turn OFF Gas to Appliance, page 10)
  • See Troubleshooting, pages 12-13.Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 17

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before servicing.
For maintenance of the inside cabinet or to access the burner and pilot assembly for cleaning or service. Remove the four screws(two located on each side) that secure
the front shell to the unit.(Figure 6) Gently lift up on the front shell to disengage the hooks and pull forward to remove it. You will now be able to access all of the internal components of the appliance.

CAUTION: You must keep control areas, burner and circulation air passageways of heater clean. Inspect these areas of heater before use. Have the heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excess lent from carpeting, bedding material, pet hair, etc.
Make sure grille guard is in place before running heater. If screen or grille guard is removed for servicing it must be replaced prior to operating the heater.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

CLEANING ODS/PILOT AND BURNER

  • Use as vacuum cleaner, pressurized air or small soft bristled brush to clean.

CLEANING BURNER PILOT AIR HOLE INLET

We recommend that you clean the unit every 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 psig.
This can be done by using a vacuum cleaner in the blow position or using compressed air in a can. If using canned air please follow the directions on the can. If you don’t follow directions on the can you could damage the burner or pilot assembly. In addition, the directions below should also be followed.

  1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.
  2. Inspect burner and pilot for dust and dirt.
  3. Blow air through the port/slots and holes in the burner.

A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. To clean the pilot assembly find the small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see figure 18). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

CLEANING HEATER CABINET

Air passageways

  • Use a vacuum cleaner or pressurized air to clean  Exterior
  • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust. ion air and create odors and possible discoloration of walls and ceilings. Mr Heater MHVFRD10LP LP-Gas Fired Room Heater fig 18

TROUBLESHOOTING

NOTE: All troubleshooting items are listed in order of operation and likely occurrence.
WARNING: Only a qualified service person should service and repair heater.
CAUTION: Never use a wire needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
Make sure grille guard is in place before running heater. If screen or grille guard is removed for servicing it must be replaced prior to operating the heater.
WARNING: If you smell gas:

  • Shut off gas supply
  • Do not try to light any appliance
  • Do not touch any electrical switch; do not use any phone in your building
  • Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover,
cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors and possible discoloration of walls and ceilings.

OBSERVED SYMPTOM POSSIBLE CAUSE REMEDY

When ignitor button is pressed in, there is a spark at the ODS/pilot but no ignition

| Control knob not fully pressed in| Press in control knob fully
Control knob not pressed in long enough| After ODS/pilot lights, keep control knob pressed in for 30 seconds
Equipment shutoff valve not fully open| Fully open equipment shutoff valve
Thermocouple connection loose at control valve| Hand tighten thermocouple nut until snug, and then tighten 1/4 turn more
Pilot flame not touching thermocouple,

which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following:

a.  Low gas Pressure

b.  Dirty or Partially clogged ODS/pilot

| a.  Contact local gas company

b.  Clean ODS/pilot (see Cleaning and Maintenance, page 11)

Thermocouple damaged| Replace thermocouple
Control valve damaged| Replace Control valve

Burner does not light after ODS/pilot is lit

| Burner orifice is clogged| Clean burner orifice (see Cleaning and Maintenance on page 11 ), or replace burner orifice
Burner orifice diameter to small| Replace burner orifice
Inlet gas pressure is too low| Contact local gas company

Delayed ignition of burner

| Manifold pressure is too low| Contact local gas company
Burner orifice is clogged| Clean burner orifice (see Cleaning and Maintenance on page 11 ), or replace burner orifice

Burner backfiring during operation

| Burner orifice is clogged or damaged| Clean burner orifice (see Cleaning and Maintenance on page 11 ), or replace burner orifice
Burner damaged| Replace burner
Gas regulator defective| Replace gas regulator

Burner plaque(s) does not glow [Infrared Only]

| Plaque damaged| Replace burner
Control knob set between locked positions| Turn control knob until it locks at desired setting
Inlet gas pressure is too low| Replace gas regulator
Slight smoke or odor during initial operation| Residues from manufacturing process| Problem will stop after a few hours of operation
OBSERVED SYMPTOM| POSSIBLE CAUSE| REMEDY
---|---|---

Heater produces a whistling noise when burner is lit

| Turning control knob to HI position when burner is cold| Turn control knob to LO position and let warm up for a minute
Air in gas line| Operate burner until air is removed from line have gas line checked by local gas company
Air passageways on heater blocked| Observe minimum installation clearances (see Figure 4 page 6)
Dirty or partially clogged burner orifice| Clean burner orifice (see Cleaning and Maintenance on page

11 ), or replace burner orifice

White powder residue forming within burner box or on adjacent walls or furniture| When heated, vapors from furniture polish, wax, carpet cleaners, etc., turn into white powder residue| Turn heater off when using furniture polish, wax, carpet cleaner or similar products

Heater produces unwanted odors.

| Heater burning vapors from paint, hair spray, glues, etc. See IMPORTANT statement on page 12| Ventilate room. Stop using odor-causing products while heater is running
Gas leak. See WARNING statement at top of page 12| Locate and correct all leaks (see Checking Gas Connections, page 9)

Heater shuts off in use (ODS operates)

| Not enough fresh air is available| Open window and/or door for ventilation
Low line pressure| Contact local gas company
ODS/pilot is partially clogged| Clean ODS/pilot (see Cleaning and Maintenance, page 11)
Gas odor even when control knob is in OFF position| Gas leak. See WARNING statement at top of page 12| Locate and correct all leaks (see Checking Gas Connections, page 9)
Control valve is defective| Replace control valve

Gas odor during combustion

| Foreign matter between control valve and burner| Take apart gas tubing and remove foreign matter
Gas leak. See WARNING statement at top of page 12| Locate and correct all leaks (see Checking Gas Connections, page 9)
Heater produces a clicking/ ticking noise just after burner is lit or shut off| Metal expanding while heating or contracting while cooling| This is common with most heaters. If noise is excessive, contact qualified service person
Moisture/condensation noticed on windows| Not enough combustion/ventilation air| Refer to Fresh Air for Combustion and Ventilation page 3 through 5
| OPERATING INSTRUCTIONS

AND OWNER’S MANUAL

| Model# MHVFRD10LP

MHVFBF10LP

---|---|---
READ INSTRUCTIONS CAREFULLY: YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS Read and

follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.

WARNING:

USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.


REPLACEMENT PARTS ORDERING INFORMATION:

PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or direct from the factory

FOR INFORMATION REGARDING SERVICE

Please call Toll-Free 800-251-0001 www.mrheater.com

Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.

Please include the model number, date of purchase, serial number and description of problem in all communication.

LIMITED WARRANTY

Mr. Heater, Inc. warrants its heaters and accessories to be free from defects in material and workmanship for a period of 1 year from date of purchase. Mr. Heater, Inc. will repair or replace this product free of charge if it has been proven to be defective within the 1-year period, and is returned at customer expense with proof of purchase to Mr. Heater, Inc. within the warranty period.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Mr. Heater, Inc. reserves the right to make changes at any time, without notice or obligation, in colors, specifications, accessories, materials and models.

PRODUCT REGISTRATION: Thank you for your purchase.
Please log in to http://www.egiregistration.com to register your product.

Mr. Heater. INC.. 45 60 W. 160TH ST.. CLEVELAND. OHIO 44135 • 800-251-0001
Mr. Heater is a registered trademarks of Mr. Heater. Inc.
© 2020. Mr. Heater. All rights reserved

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MR Heater User Manuals

Related Manuals