SYRIS SYSR86N-HBX1 Standard TCP/IP Reader Instruction Manual

June 6, 2024
SYRIS

SYSR86N-HBX1
Standard TCP/IP Reader
Manual

SYRIS SYSR86N-HBX1 Standard TCP

Version 01.04
2016/04/25

 Features & Specification

Feature:

  • Standard 86.0(W)x86.0(H) mm
  •  Waving Hand / Touch Panel to Access Door
  • Support to read standard 13.56MHz RFID card
  • Relay for door bell、light or EM lock
  • Quick Setup via Micro USB
  • Support Standard Wiegand interface
  • Door sensor detective ( Door Open Timeout、Forcible Entry Alarm )
  • Support Black card List
  • Support to access door via Bluetooth、Xtive RFID Tag

Specification:

Card Frequency 13.56MHz
Card Types ISO14443A/B / ISO15693 / Mifare / NTAG203/ DESFire
Card Read Range 1~5 cm
Ethernet 10/100 base-T Ethernet
Wi-Fi 802.11 b/g/n
Black/White List 500
Event Log 1180
Baud Rate 19,200 bps (4,800~230,400 bps)
Read Card Time 0.1 second
Keypad 1 Key (Capacitive Touch)
IR Sensor 1 IR Sensor, adjustable range 0-10 cm
Status Indicator Tricolor LED(RGB)
Touch Status Indicator Tricolor LED(RGB)
Interface Ethernet, Wi-Fi, Wiegand, RS-485, USB
Device ID 0001~9999
Digital Input Up to 3 (1 no-voltage DI +2 no-voltage DI share the same port

with
Digital Output| Up to 4 (2 Relay + 2 output share the same port with Wiegand)
Voice Output| On-Board Buzzer
Operation/Storage Temperature| -10℃~+60℃ / -20℃~+70℃
Power| 8V ~ 28V DC / 1W ~ 6W
Size(mm)| 86(W) x 86(H) x 41.6(D) mm (No Wire Included)

 Wiring Diagram

SYRIS SYSR86N-HBX1 Standard TCP -FIG

SYRIS SYSR86N-HBX1 Standard TCP -FIG 2

Network Parameter Setting

  1.  Execute “NET_Discover_V0110.exe” and press to search SY86N series product.

  2. Factory default IP is “192.168.1.101”. Users can check the MAC address from the product sticker with IP to confirm the device.
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 3

  3. Double click IP (192.168.1.101) to open the web configure page(http://192.168.1.101)
    Default login ID / Password : admin / admin
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 4

  4. Default Net Mode is the same as the following. Users can modify Net Mode and other parameters. If the device cannot communicate properly after setting, the user can reset the NET module via Micro USB.

SYRIS SYSR86N-HBX1 Standard TCP -FIG 5

Communication Parameter Factory Default
Serial Configure 230400,8,n,1
Serial Framing Length 1050
Locale/Remote Port Number 5001

Network Mode Switch

86N series device support 4 network modes: Dual mode、ETH(Ethernet)、Wi-Fi AP 、Wi-Fi client.

Default Ethernet (DHCP) +Wi-Fi AP mode
ETH-SERIAL Ethernet only (Factory Default)
WIFI(CLIENT)-SERIAL Wi-Fi client mode
WIFI(AP)-SERIAL Wi-Fi AP mode

SYRIS SYSR86N-HBX1 Standard TCP -FIG B

  1. ETH-SERIAL: Factory default is ETH-SERIAL. ( Standard TCP/IP Reader )
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 6
    When the user modifies the IP and clicks on Apply button, the device will reboot and apply the setting after 30 seconds .
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 7

  2. Wi-Fi client mode:86N can be set to communicate via Wireless AP without Ethernet.
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 8

    SYRIS SYSR86N-HBX1 Standard TCP -FIG 10

SSID: Enter the SSID from AP you will connect to the network.
Scan : The user can scan AP in the range of 86N and select one to connect. But user cannot scan the AP
after changing the default network mode (Ethernet only) to Wi-Fi (Client). 86N need to power off / on to
enable the scan function.
Encrypt Type: Select Encrypt type for AP connection.
Password: Enter the password for AP.
IP Type: DHCP is the default mode. If the user has to set up a static IP, please select Static.
PS: Wi-Fi MAC address is Ethernet MAC subtract 1.
Ex. Ethernet MAC : AC:A2:13:B5:5A:B5, Wi-Fi MAC : AC:A2:13:B5:5A:B 4

  1. Wi-Fi AP mode: Setup 86N as AP(Wireless Access Point) for a client device to communicate. This mode is usually for setting devices.
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 62

    SYRIS SYSR86N-HBX1 Standard TCP -FIG K

SSID: Setup 86N device’s SSID.
Encrypt Type : Select Encrypt Type for the AP.
Password: Setting 86N device’s Wi-Fi password.
IP address: Setting 86N device’s Wi-Fi IP address.
Subnet Mask: Setting 86N device’s Wi-Fi subnet mask.

  1. Default mode: Ethernet (DHCP) +Wi-Fi AP mode.
    It’s Dual-Mode ( Ethernet and Wi-Fi AP,but Ethernet only supports DHCP.)SYRIS SYSR86N-HBX1 Standard TCP -FIG H

    SYRIS SYSR86N-HBX1 Standard TCP -FIG E

SSID: Setup 86N device’s SSID.
Password: Setting 86N device’s Wi-Fi password.

USB Connectio

Setup 86N parameter via Micro USB.

SYRIS SYSR86N-HBX1 Standard TCP -FIG V

  1. Install USB driver ”CDC_USB_Driver_VCP_V1.4.0_Setup.exe”

  2. System will generate a virtual COM port.
    For example. Check port in device manager. (below picture is COM 3)
    SYRIS SYSR86N-HBX1 Standard TCP -FIG YUsers also can update drivers manually. The driver is saved in the folder that is the same as the following.
    SYRIS SYSR86N-HBX1 Standard TCP -FIG Y

  3. Get device Model information and serial number by using V7 Tools with the correct COM port.
    SYRIS SYSR86N-HBX1 Standard TCP -FIG Q

  4. V7 Tools also provides Ethernet mode. The user only needs to fill in the correct IP and Port and click to set up.

SYRIS SYSR86N-HBX1 Standard TCP -FIG 11

 V7 Tools Tool Parameter Setting

  1. Basic:
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 11
    Basic: Get device serial number、device ID and firmware version
    Warm Start: Reboot 86N
    Initial: Restore 86N to factory default (It does NOT include network setting).
    NET Initial (6 sec): Restore network parameter of 86N to Default mode. The user has to set up by referring to the following information after restoring the device to factory default. Communication Parameter| Factory Default
    ---|---
    Serial Configure| 230400,8,n,1
    Serial Framing Length| 1050
    Locale/Remote Port Number| 5001

  2.  Reader
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 14 Set Interface: Setup reader’s communication interface. Default is “Wiegand & RS485”.
    Set Message Mode: Click on the option active to enable the message mode setting. Users can set up an 86N message display on the panel.
    Card LED: Time for reading card LED ON, default is 30 x 10ms
    Card Beep: Time for reading card beep on, default is 30 x 10ms
    ISO14443A/B/ISO15693 :
    Same Card Delay: Setup time gap for reading the same card, default is 10 x100ms (1 second)
    Green Mode: Slow down the card read speed to power saving.
    Reset: Reset RF IC after reading the card.
    Card Type: Choose card type to enable 86N read specific card.
    UID(A): Read ISO14443A Card UID.
    Block: Read Block data (Must disable another card type).
    UID(B): Read ISO14443B Card UID.
    GUID(B): Read the China second generation of resident identification card.
    ISO15693: Read ISO15693 Card UID
    7 byte: Read 7byte format Card UID
    Card Test: Test the reader function.
    86 Series-Touch IR Sensor:
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 15 HF/LF Read:
    Setup read card mode
    Auto: Read card automatically. Users do not have to touch the 86N panel or trigger the IR sensor.
    Touch Key: Only read the card when the device panel is touched. Flashcard time is within 10 seconds. The LED indicator will turn red in the period.
    IR Sensor: Only read the card when IR is triggered. Flashcard time is within 10 seconds. The LED indicator
    will turn red in the period.
    Touch Key or IR Sensor: Users can flashcards when the device panel is touched or IR is triggered. Flashcard
    time Bluetooth within 10 seconds. The LED indicator will turn red in the period.
    Off: Turn off the read card function.
    Touch Key: Setup output mode when Touch Key is triggered.
    IR Sensor: Setup output mode when IR is triggered.
    IR Power: Setup IR sensor power. It’s related working range. (100% is farthest,10% is closest).

  3. 86 Series-
    SYRIS SYSR86N-HBX1 Standard TCP -FIG WBluetooth Mode: Setup receiving mode for Bluetooth signal.
    Auto: Receive Bluetooth signal automatically.
    IR Sensor: Receive Bluetooth signal after triggering IR sensor. The initial time is 10 seconds. (the time is fixed)
    Off: Turn off Bluetooth.
    Bluetooth PIN: The default pin is 8888
    BT3.0+4.0: Setup Bluetooth working mode. Default is BT3.0+4.0.(Auto-detect)
    BT Name: Setup device Bluetooth name. Default is SYBT_(+S/N). It’s the name for searching with
    Bluetooth.
    BT Same: Setup Bluetooth Open Door time of the same card. Default is 50 (50 x 0.1=5 second).

  4. 86 Series-Xtive TAG
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 17 Xtive TAG:
    Setup read mode for the active RFID tag.
    Key: Only receive a signal from the active RFID tag that pressed the button.
    Auto: Receive active RFID Tag signal automatically.
    IR Sensor:86N only receives strive RFID Tag signal when IR is triggered. Start read time is about 10 seconds.
    Off: Turn off the function to read Active RFID tag
    Exciter ID: This parameter should use with SYRIS exciter, default values are “0” which means disable. If this
    function enables, the reader will only receive the tag’s signal which includes a set exciter ID.
    Same: Same card time. Default is 50 (50 x 0.1=5 second)
    Gain: Set Gain (1~13) to control the reader’s read range.
    Level 13 is the max range (default setting), Level 1 is the shortest read range.
    RSSI: Adjust RSSI level (0~250) to filter TAG which has a low RSSI signal in the reader.
    Ex. Set RSSI Level to 120, Reader will receive tag which RSSI is stronger than

  5. 86 Series-DI/DO Mode
    DI/DO Mode Setting-RS485 Mode (Communication interface have to switch into RS485)
    SYRIS SYSR86N-HBX1 Standard TCP -FIG 19DO1 : Setup DO1 motion parameter
    RS485:Control DO1 motion via RS485.
    Touch Key: To activate DO1 by using a touch panel keypad.
    IR Sensor: To activate DO1 by using an IR sensor.
    Touch Key or IR Sensor: To activate DO1 by using a touch panel keypad OR IR sensor. (Default)
    DI2/DO3 : Setup the contact mode ( DI2 or DO3 )
    DI2:Setup the contact does work as DI2 (Default)
    DO3 RS485:Setup the contact does work as DO3. It is triggered via RS485.
    DO3 Touch Key: The contact does work as DO3. It is triggered by a touch key.
    DO3 IR Sensor: The contact does work as DO3. It is triggered by IR.
    DO3 Touch Key or IR Sensor: The contact does work as DO3. It is triggered by a touch key or IR.
    DI3/DO4: Setup the contact mode ( DI3 or DO4 )
    DI3:Setup the contact does work as DI3 (Default)
    DO4 RS485:Setup the contact does work as DO4. It is triggered via RS485.
    DO4 Touch Key: The contact does work as DO4. It is triggered by a touch key.
    DO4 IR Sensor: The contact does work as DO4. It is triggered by IR.
    DO4 Touch Key or IR Sensor: The contact does work as DO4. It is triggered by a touch key or IR.
    PS. DO3 and DO4 need to connect an extra Relay module (MDRL02) to work.
    MDRL02 WD0 connects DO3(86N). MDRL02 WD1 connects DO4(86N).
    DI/DO Mode Setting – Wiegand Mode (Communication interface have to switch into Wiegand )

SYRIS SYSR86N-HBX1 Standard TCP -FIG 20

DO1: Setup DO1 motion parameter
Touch Key: To activate DO1 by using a touch panel keypad.
IR Sensor: To activate DO1 by using an IR sensor.
Touch Key or IR Sensor: To activate DO1 by using a touch panel keypad OR IR sensor. (Default)
MESSAGE →Setup contact motion mode
LEDGI: MESSAGE contact is grounding, reader indicator green on (Default).
LEDRI: MESSAGE contact is grounding, reader indicator red on.
BEEPI: MESSAGE contact is grounding, reader buzzer on.
DO1:MESSAGE contact is grounding, reader DO1 on.
DO2:MESSAGE contact is grounding, reader DO2 on.
DO Time : DO outputs activate time

SYRIS SYSR86N-HBX1 Standard TCP -FIG N

Setup activated time to each DO point. DO1、DO2 are reader Relay. DO3、DO4 are extra Relay modules.
All of the default time is 50 x 0.1 sec (5 seconds).