VIZULO CL Colibri LED Street Luminaire Instruction Manual

September 14, 2024
VIZULO

VIZULO CL Colibri LED Street Luminaire

Product Information

Specifications:

  • Product Name: VIZULO Colibri LED street luminaire
  • Model: PH2
  • Standard: IEC EN 60598
  • IP Rating: IP66
  • Input Voltage: 200 – 240 V
  • Impact Protection Rating: IK08 IK09
  • Weight:
    • Standard – 2.10 – 2.90 kg
    • L-Type – 3.40 – 4.60 kg
    • Floodlight – 2.00 – 2.80 kg

Product Usage Instructions

Mounting Instructions:
Follow the steps below for proper mounting of the VIZULO Colibri LED street luminaire:

  1. Ensure the mounting location is suitable and secure.
  2. Attach the luminaire using the provided mounting console based on the desired installation type (Side Entry, Post Top, L-Type console, or Floodlight).
  3. Securely fasten the luminaire according to the specified torque values provided in the manual.

Power Connection:
Connect the power supply to the luminaire as follows:

  1. Identify the correct power connection based on the luminaire type (CLASS I, CLASS II, or CLASS II + DALI).
  2. Ensure proper insulation stripping and wire connections as indicated in the manual.
  3. Do not overpress the glass fixator during the connection process.

Safety Instructions:
For safety reasons, adhere to the following precautions:

  • Handle electrical connections with caution to prevent electrical shock.
  • Only replace the light source with assistance from a qualified person.
  • Follow specific instructions for NEMA/ZHAGA Socket usage and IP66 compliance.

FAQs

Q: Can I mount the luminaire without using the provided console?

A: No, it is recommended to use the specified mounting console for secure installation.

Q: What should I do if the power connection wires are not long enough?

A: Do not extend the wires manually; contact a professional to address this issue safely.

Q: How often should I check the luminaire for maintenance?

A: Regularly inspect the luminaire for any damage or loose connections every six months to ensure optimal performance.

Models

NETTO WEIGHT

WEIGHT MIN – MAX
STANDARD – 2.10 – 2.90 kg / L – TYPE – 3.40 – 4.60 kg / FLOODLIGHT – 2.00 – 2.80 kg

DIMENSIONS

Standard Side Entry/Post Top

L – Type Console

Floodlight

Mounting Instruction

Standard Mounting

Power connection

Precaution

Caution, risk of electrical shock!
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

ATTENTION!
In the case of NEMA/ZHAGA Socket. IP66 applies only to the luminaire body and for the connection between the luminaire body and NEMA/ZHAGA Socket and does not apply to any mounted control device and connection between the control device and the NEMA/ZHAGA Socket.

The luminaire should be positioned so that prolonged staring into the luminaire is not expected from a distance closer than shown in the table above.

WARNING!

  • Do not touch LED modules!
  • Do not put any tools or other items on

LED modules!

  • In case any LED is physically damaged (example shown below) the warranty is void.

Energy efficiency class of contained light source(s)

MCB/Inrush current table

Tridonic LED driver (No dim/Midnight dimming/DALI)

STANDARD / HIGH DENSITY| IN-RUSH CURRENT (peak/duration)| B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A| C32A| C40A
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
4-6 LED, 5-10W| 9 A (253 μs)| 28| 36| 44| 51| 63| 81| 102| 46| 60| 73| 85| 106| 136| 170
6-12 LED, 11-26W| 15 A (226 μs)| 19| 25| 30| 37| 46| 59| 74| 31| 41| 50| 61| 76| 97| 122
12-16 LED, 20-43W| 25 A (236 μs)| 12| 16| 20| 26| 32| 41| 52| 20| 26| 33| 43| 53| 68| 86
ECO|  | B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A| C32A| C40A
4-4 LED, 5-11W| 9 A (253 μs)| 28| 36| 44| 51| 63| 81| 102| 46| 60| 73| 85| 106| 136| 170
4-4 LED, 12-26W| 15 A (226 μs)| 19| 25| 30| 37| 46| 59| 74| 31| 41| 50| 61| 76| 97| 122
4-8 LED, 20-43W| 25 A (236 μs)| 12| 16| 20| 26| 32| 41| 52| 20| 26| 33| 43| 53| 68| 86

Tridonic LED driver (Zhaga)

STANDARD / HIGH DENSITY| IN-RUSH CURRENT (peak/duration)| B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A| C32A| C40A
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
4-6 LED, 5-11W| 8 A (253 μs)| 19| 25| 30| 38| 47| 90| 76| 31| 41| 50| 63| 78| 100| 126
6-12 LED, 12-26W| 15 A (226 μs)| 16| 21| 25| 33| 41| 52| 66| 26| 35| 41| 55| 68| 88| 110
12-16 LED, 20-43W| 20 A (236 μs)| 11| 14| 27| 22| 27| 35| 44| 18| 23| 28| 36| 45| 57| 72
ECO|  | B10A| B13A| B16A| B20A| B25A| B32A| B40A| C10A| C13A| C16A| C20A| C25A| C32A| C40A
4-4 LED, 5-11W| 8 A (253 μs)| 19| 25| 30| 38| 47| 60| 76| 31| 41| 50| 63| 78| 100| 126
4-4 LED, 12-26W| 15 A (226 μs)| 16| 21| 25| 33| 41| 52| 66| 26| 35| 41| 55| 68| 88| 110
4-8 LED, 20-43W| 20 A (236 μs)| 11| 14| 17| 22| 27| 35| 44| 18| 23| 28| 36| 45| 57| 72

Terms of use and maintenance

Before the luminaire is turned on, it should be mounted according to this mounting instruction or any other applicable regulations.

Mounting instructions
Mounting of the luminaire must be performed by a qualified person according to the following instructions:

  • The warranty of the luminaire does not apply if the mounting of the luminaire has been performed in precipitation (rain, snow, hail). unate area by un aran DNA picabe a ver has been used to drive the luminaire.
  • The warranty of the luminaire does not apply if it has been used at an unsuitable ambient temperature or has been supplied by voltage outside of the specified range.
  • The warranty of the luminaire does not apply if the LED driver program has been changed in any way.
  • The warranty of the luminaire does not apply if the logged history data of the LED driver has been deleted from VIZULO
  • The warranty of the luminaire does not apply if it has been mounted at unspecified angles or upside down (luminaire glass directed up), or if it has been completely submerged underwater.

Safety instructions
Any actions with the luminaire must be performed by a qualified person, who is certified according to national regulations and requirements.

To prevent any accidents person installing the luminaire must follow national safety requirements and instructions:

  • The label containing the technical parameters of the luminaire has to be studied before the work on it has begun.
  • Any luminaire build or design changes are prohibited.
  • The luminaire must be used in good technical condition and according to this instruction.
  • Only VIZULO-authorized spare parts and accessories can be used to repair the luminaire.
  • The repair of the luminaire has to be performed by a qualified and certified person.

Maintenance and repair
The luminaire has to be disconnected from the electrical grid before it is opened and/or repaired!

  • The person working with the luminaire must follow national regulations and legislations that apply to the maintenance and testing of electrical or electronic appliances.
  • The luminaire may need to be cleaned depending on its environment.
  • Only a damp cloth or a sponge may be used to clean the luminaire. Use only household detergents diluted by water.
  • Only VIZULO-authorized spare parts may be used for the luminaire.
  • Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
  • LED modules, lenses, and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoors to avoid water entering the luminaire.
  • Spare parts (lens, LED modules, and drivers) should be ordered from the information available on the luminaire label.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals