MEAN WELL MDR-60-24 60W Single Output Industrial DIN Rail Power Supply Owner’s Manual

June 1, 2024
MEAN WELL

MEAN WELL MDR-60-24 60W Single Output Industrial DIN Rail Power Supply

Product Information

Specifications:

  • Product Name: 60W Single Output Industrial DIN Rail Power Supply
  • Series: MDR-60
  • GTIN CODE: [Insert GTIN CODE]
  • Features:
    • Universal AC input/Full range
    • Protections: Short circuit / Overload / Over voltage
    • Cooling by free air convection
    • Can be installed on DIN rail TS-35/7.5 or 15
    • Class I, Div 2 Hazardous Locations T4
    • LED indicator for power on
    • DC OK relay contact
    • No load power consumption

Product Usage Instructions

Installation :

  1. Ensure the power supply is compatible with your system’s requirements.
  2. Mount the power supply on a DIN rail TS-35/7.5 or 15 securely.
  3. Connect the universal AC input to the power source.
  4. Verify proper cooling by allowing free air convection around the power supply.

Operation:

  1. Check the LED indicator for power status.
  2. Ensure proper connections for DC output.
  3. Monitor for any overload or short circuit issues.

Maintenance :

  1. Regularly check for dust accumulation and clean if necessary.
  2. Inspect for any signs of wear or damage and replace components as needed.

FAQ

  • Q: What should I do if the DC OK relay contact is not functioning?
    A: Check the connections and ensure they are properly secured. If the issue persists, contact customer support for assistance.

  • Q: Can the power supply be used in hazardous locations other than Class I, Div 2 areas?
    A: No, it is recommended to only use the power supply in Class I, Div 2 Hazardous Locations T4 as specified.

60W Single Output Industrial DIN Rail Power Supply
MDR-60 series

Features

  • Universal AC input/Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Class I, Div 2 Hazardous Locations T4
  • LED indicator for power on
  • DC OK relay contact
  • No load power consumption<0.75W
  • 100% full load burn-in test
  • 3 years warranty

GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx

MEAN-WELL-MDR-60-24-60W-Single-Output-Industrial-DIN-Rail-Power-Supply-
\(2\)

MODEL MDR-60-5 MDR-60-12 MDR-60-24 MDR-60-48
OUTPUT DC VOLTAGE 5V 12V 24V
RATED CURRENT 10A 5A 2.5A 1.25A
CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~ 2.5A 0 ~ 1.25A
RATED POWER 50W 60W 60W 60W
RIPPLE & NOISE (max.) **Note.2** 80mVp-p 120mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 5 ~ 6V 12 ~ 15V 24 ~ 30V 48 ~ 56V
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±1.0% ±1.0% ±1.0% ±1.0%
LOAD REGULATION ±1.5% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME Note.5 500ms, 30ms/230VAC            500ms,

30ms/115VAC at full load
HOLD UP TIME (Typ.)| 50ms/230VAC            20ms/115VAC at full load
INPUT| VOLTAGE RANGE| 85 ~ 264VAC           120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 78%| 85%| 87%| 87%
AC CURRENT (Typ.)| 1.8A/115VAC            1A/230VAC
INRUSH CURRENT (Typ.)| COLD START 30A/115VAC           60A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC


PROTECTION

| OVERLOAD| 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 6.25 ~ 7.25V| 15.6 ~ 18V| 31.2 ~ 36V| 57.6 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION| DC OK SIGNAL| Relay contact rating(max.): 30V/1A resistive
ENVIRONMENT| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
SAFETY & EMC **(Note 4)| SAFETY STANDARDS| Ul508, UL62368-1, TUV BS EN/EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 60950.1 , IS13252(Part1)/IEC60950-1(except 48V) approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B
EMC IMMUNITY**| Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3, heavy industry level, EAC TP TC 020


OTHERS

| MTBF| 2355.2K hrs min.       Telcordia SR-332 (Bellcore) ; 489.9K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION| 4090100mm (WHD)
PACKING| 0.33Kg; 42pcs/14.8Kg/0.82CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
  5. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  6.  Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set-up time.
  7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).

Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-MDR-60-24-60W-Single-Output-Industrial-DIN-Rail-Power-Supply-
\(3\)

Block Diagram

MEAN-WELL-MDR-60-24-60W-Single-Output-Industrial-DIN-Rail-Power-Supply-
\(4\)

Contact Close PSU turns on / DC OK.
Contact Open PSU turns off / DC Fail.
Contact Ratings (max.) 30V/1A resistive load.
  • Derating Curve

  • Output Derating VS Input Voltage
    MEAN-WELL-MDR-60-24-60W-Single-Output-Industrial-DIN-Rail-Power-Supply-
\(5\)

  • Downloaded from Arrow.com.

  • File Name: MDR-60-SPEC 2024-02-19

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals