MOXA UC-8100A-ME-T Series Arm-Based Computers Installation Guide
- June 6, 2024
- MOXA
Table of Contents
UC-8100A-MET Series
Quick Installation Guide
Technical Support Contact Information
www.moxa.com/support
P/N: 1802081121013
Overview
The UC-8100A-MET computing platform is designed for embedded data acquisition applications. The UC-8100A-ME-T computer comes with two RS-232/422/485 serial ports and dual 10/100 Mbps Ethernet LAN ports, as well as a Mini PCIe socket to support cellular modules. These versatile communication capabilities let users efficiently adapt the UC-8100A-MET to a variety of complex communications solutions.
Package Checklist
Before installing the UC-8100A-MET, verify that the package contains the
following items:
- UC-8100A-MET embedded computer
- Power jack
- Console cable
- Quick installation guide (printed)
- Warranty card
IMPORTANT!
**** Notify your sales representative if any of the above items are missing or damaged.
UC-8100A-MET Panel Layout
The following figures show the panel layouts of the UC-8100A-MET:
Top Panel View
ATTENTION
**** Use 16-24 AWG (1.318 to 0.205 mm wiring for connections to V+, V-, and GN. Both the power input and earthing conductor ) wire size should be the same.
Bottom Panel View
Front Panel View
**LED Indicators
**
LED Name
| Color|
Function
---|---|---
| USB| Green| Steady On| USB device is connected and working normally.
Off| The USB device is not connected.
| SD| Green| Steady On| SD Card inserted and working normally.
Off| SD card is not detected.
| Power| Green| The power is on and the computer is working normally.
Off| The power is off.
| LAN1/LAN 2 (RJ45 connector)| Green| Steady On| 100 Mbps Ethernet link
Blinking| Data transmission inprogress
Yellow| Steady On| 10 Mbps Ethernet link
Blinking| Data transmission in progress
Off| Ethernet is not connected.
**| Wireless Signal Strength| Green Yellow Red| The number of glowing LEDs
indicates the signal strength.
3 (Green + Yellow + Red): Excellent 2 (Yellow + Red): Good
1 (Red): Poor
Off| The wireless module is not detected.
USR**| User-defined| Green| This LED can be defined by users. For details,
refer to Hardware User’s
Manual.
| Programmable diagnostic LEDs| Green Yellow Red| These three LEDs are
programmable. For details, refer to the “Default Programmable Button
Operation” section in the Hardware User’s Manual.
Specifications
Model | UC-8112A-ME-T-LX |
---|---|
Input Current | 700 mA @ 12 VDC |
Input Voltage | 12 to 36 VDC (3-pin terminal block, V+, V-, SG) |
Power Consumption | 6 W (without cellular module and external USB device |
attached)
Operating Temperature| Without LTE module preinstalled: -40 to 85°C (-40
to 185°F)
With LTE module preinstalled:-40 to 70°C (-40 to 158°F)
Storage Temperature| -40 to 85°C (-40 to 185°F)
ATEX Information|
Certificate Number: DEMKO 19 ATEX 2295X Certification String: Ex nA IIC T4 Gc
Ambient Range: -40°C ≦ Tamb ≦ 85°C (without LTE module preinstalled) Ambient
Range: -40°C ≦ Tamb ≦ 70°C (with LTE module preinstalled) Rated Cable Temp ≧
90°C
IECEx Certificate no.| IECEx UL 19.0107X
---|---
Address of Manufacturer| No. 1111, Heping Rd., Bade Dist., Taoyuan
City 334004, Taiwan
Hazardous Location| EN 60079-0:2012+A11:2013/IEC 60079-0 Ed.6 EN
60079-15:2010/IEC 60079-15 Ed.4
Installing the UC-8100A-ME-T
DIN-rail Mounting
The aluminum DIN-rail attachment plate is already attached to the product’s
casing. To mount the UC-8100A-MET on to a DIN rail, make sure that the stiff
metal spring is facing upwards and follow these steps.
- Pull down the bottom slider of the DIN-rail bracket located at the back of the unit
- Insert the top of the DIN rail into the slot just below the upper hook of the DIN-rail bracket.
- Latch the unit firmly onto the DIN rail as shown in the illustrations below.
- Push the slider back into place.
Wall Mounting (Optional)
The UC-8100A-MET can be mounted with a wall-mounting kit that needs to be
purchased separately. Follow these steps to mount the computer on to a wall:
Step 1
Use four screws to fasten the thewall-mounting brackets on the left panel of
the computer.
Step 2
Use another four screws to mount the computer on a wall or a cabinet
Connector Description
Power Connector
Connect the power jack (in the package) to the UC-8100A-ME-T’s DC terminal
block (located on the top panel), and then connect the power adapter. It takes
about 30 seconds for the system to boot up. Once the system is ready, the
Power LED will light up.
WARNING
EXPLOSION HAZARD!
Do not disconnect equipment unless the power has been removed or the area is
known to be non-hazardous.
Grounding the UC-8100A-MET
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
SG: The Shielded Ground (sometimes called Protected Ground) contact is the top contact of the 3-pin power terminal block connector when viewed from the angle shown here. Connect the SG wire to an appropriate grounded metal surface.
Ethernet Ports
The two 10/100 Mbps Ethernet ports (LAN 1 and LAN 2) use RJ45 connectors.
Pin | Signal |
---|---|
1 | Tx+ |
2 | Tx- |
3 | Rx+ |
6 | Rx- |
Serial Ports
The two serial ports (P1 and P2) use terminal connectors. Each port can be
configured by software for RS-232, RS-422, or RS-485 mode. The assignments for
the ports are shown in the following table:
Pin | RS-232 | RS-422 | RS-485 |
---|---|---|---|
1 | TXD | TXD+ | – |
2 | RXD | TXD- | – |
3 | RTS | RXD+ | D+ |
4 | CTS | RXD- | D- |
5 | GND | GND | GND |
SD/SIM card Sockets
The UC-8100A-ME-T comes with an SD socket for storage expansion, and a SIM
card socket for cellular communication. The SD card and SIM card sockets are
located at the lower part on the front panel. To install the cards, remove the
screw and the protection cover to access the socket, and then insert the SD
card or the SIM card into the sockets directly. You will hear a click when the
cards are in place. To remove the cards, push the cards in before releasing
them.
Console Port
The console port is an RS-232 port that can be connected to a 4-pin pin header
cable. You can use this port for debugging or firmware upgrades.
Pin | Signal |
---|---|
1 | TxD |
2 | RxD |
3 | NC |
4 | GND |
USB Port
The USB 2.0 port is located at the lower part of the front panel and supports
a USB storage device driver. By default, the USB storage is mounted at
/mnt/usbstorage.
Antenna Connectors
There are three antenna connectors on the front panel of the UC-8100A-ME-T. W1 and W3 are for cellular modules, and W2 is for the GPS module. All three connectors are of SMA type.
Real-time Clock
The real-time clock in the UC-8100A-MET is powered by a lithium battery. We
strongly recommend that you do not replace the lithium battery without the
help of a Moxa support engineer. If you need to change the battery, contact
the Moxa RMA service team.
ATTENTION
**** There is a risk of explosion if the battery is replaced with incorrect type of battery.
Accessing the UC-8100A-ME-T Using a PC
You can use a PC to access the UC-8100A-MET by one of the following methods:
A. Through the serial console port with the following settings:
Baudrate=115200 bps, Parity=None, Data bits =8, Stop bits =1,
Flow Control =None
ATTENTION
**** Remember to choose the “VT100” terminal type. Use the console cable to
connect a PC to the UC-8100A-ME-T’s serial console port
B. Using SSH over the network. Refer to the following IP addresses and login
information:
| Default IP Address| Netmask
---|---|---
LAN 1| 192.168.3.127| 255.255.255.0
LAN 2| 192.168.4.127| 255.255.255.0
Login: moxa
Password: moxa
ATTENTION
-
The equipment shall only be used in an area of not more than pollution degree 2, as defined in IEC/EN 60664-1.
-
The equipment shall be installed in an enclosure that provides a degree of protection not less than IP 54 in accordance with IEC/EN 60079-15 and accessible only by the
use of a tool. -
These devices are open-type devices that are to be installed in an enclosure with a tool removable cover or door, suitable for the environment.
-
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous locations only.
-
ANTENNAS INTENDED FOR USE IN CLASS I, DIVISION 2 HAZARDOUS LOCATIONS MUST BE INSTALLED WITHIN THE END-USE ENCLOSURE. FOR REMOTE MOUNTING IN ANUNCLASSIFIED LOCATION, ROUTING AND INSTALLATION OF THE ANTENNAS SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE REQUIREMENTS (NEC/CEC) Sec. 501.10(b).
-
The “USB, RS-232/422/485 serial ports, LAN1, LAN2, and console ports” and Reset Button may only be accessed for equipment set-up, installation, and maintenance at a non-hazardous location. These ports and their associated interconnecting cables must remain inaccessible within the hazardous location.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>