VIXEN GO VGW0416-25K Hidden Flat Wire 4 Conductor 16 Gauge Paintable Cable User Manual

June 1, 2024
VIXEN GO

VIXEN GO VGW0416-25K Hidden Flat Wire 4 Conductor 16 Gauge Paintable

Cable

VIXEN-GO-VGW0416-25K-Hidden-Flat-Wire-4-Conductor-16-Gauge-Paintable-Cable-
product

Product Information

Specifications

  • Product Name: 16AWG 4-Conductor Ultra Flat Cable (25 FT)
  • Includes: Quick Connector Adapter (Terminal Block) x 4
  • Maximum Voltage Rating: 36V
  • Recommended Usage: Low voltage electrical connections such as LED lighting, doorbells, security cameras, and speakers

Product Usage Instructions

Before Installation

Read through the entire instruction guide before starting the installation.

Safety Instructions

  • Use safety precautions with sharp tools like scissors or knives.

  • Complete all connections on the flat cable and connectors
    before connecting to the device or power line.

  • Recommended for indoor use only.

Installation Steps

  1. Ensure access to the installation location is clear of obstacles.
  2. Cut the flat cable down the middle from one end to create two smaller strips.
  3. Cut one of the smaller strips shorter than the other.
  4. Remove adhesive paper and apply the flat wire to the installation surface.
  5. Install terminals on each end of the strip using terminal blocks.
  6. Connect device wires to the terminal block using a flat head screwdriver.
  7. Secure the terminal block if needed and close the terminal door.
  8. Repeat steps for the other end of the strip.
  9. Prime or paint the flat wire for concealment if desired.

FAQ

  • Q: Can this flat cable be used outdoors?
  • A: Although it may work well in places like a porch or patio, indoor use is recommended for this product.
  • Q: What is the maximum voltage rating for this cable?
  • A: The maximum voltage rating for this cable is 36V. Do not exceed this value.

BEFORE BEGINNING YOUR INSTALLATION

  • Read through the entire instruction guide before getting started with the installation.

CONTENTS

  • 16AWG 4-Conductor Ultra Flat Cable (25 FT)

  • Quick Connector Adapter (Terminal Block) x 4

  • Only use this flat cable in low voltage electrical connections such as with LED lighting, doorbells, security cameras and speakers.

  • Never exceed the maximum voltage rating value of 36V.

SAFETY INSTRUCTIONS

  • Use safety precautions while working with scissors or sharp knives.
  • Make sure to first finish all connections on the flat cable, quick connectors, etc. before connecting the line to the device or power line.
  • Although this product may work well in places such as a porch or patio we recommend its use indoor only.

INSTALLATION INSTRUCTIONS

  • Ensure full access to the location where you are planning to install the flat cable, make sure there are no furniture or other objects that will obstruct the installation area.
  • Starting with one end of the strip, using the scissors, cut down the middle from the end about 4″ so you have one strip that ends in two smaller strips with two conductors on each side. Image 1
  • Get one of the smaller strips and measure about 2-1/2″ from the end and cut it from its edge to the middle so one of the smaller strips is shorter than the other one. Image 2
  • Remove the adhesive paper (bottom layer) and start applying the flat wire to the surface where it is going to be installed. Image 3 and 4
  • Once you have the strip installed you can proceed to install the terminals. Four terminal blocks are needed, two for each end.
  • Starting with the shorter strip, open the terminal block and with the door half way opened, center the flat cable and insert thought the opening between the door and the bottom of the terminal block. There is a stopper inside the terminal block that will indicate how far the strip must be inserted (about 1/2″). IMPORTANT: Make sure the two conductors on the flat wire are touching the contacts inside the terminal block. Image 5 and 6
  • Using a flat head screwdriver, unscrew both screws and connect your device’s wires to the terminal block, then tighten the screws. This terminal is compatible with up to 10AWG wires. Image 7
  • Before closing the terminal block, you may choose to secure it to the surface using two screws (not supplied), then close the terminal door. Image 7 (circled) and 8
  • Repeat these steps with the longer strip and then do the same on the other end of the 4 conductor strip.
  • Now you can proceed to prime or paint the flat wire for maximum concealment. Image 9

VIXEN-GO-VGW0416-25K-Hidden-Flat-Wire-4-Conductor-16-Gauge-Paintable-Cable-
fig-1

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>