REMINGTON REM-125-OFR-B Kerosene Radiant Heater User Manual
- June 4, 2024
- Remington
Table of Contents
REMINGTON REM-125-OFR-B Kerosene Radiant Heater User Manual ~~
~~
DANGER
GENERAL HAZARD WARNING:
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can
result in fire or explosion that can cause property loss, bodily injury, or
loss of life. Only persons who can follow and understand these instructions
should operate or service this heater. If you need heater info; such as an
operating manual, labels, etcetera, contact Pinnacle Climate Technologies at
800-641 6996.
DANGER
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES WITHOUT ADEQUATE
VENTILATION. THIS HEATER IS SUITABLE FOR OUTDOOR USE, AND INDOOR USE ONLY IN
WELL VENTILATED AREAS. INDOOR USE PERMITTED ONLY FOR: THE TEMPORARY HEATING OF
ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, ALTERATION
OR REPAIR. This is an unvented portable heater that uses air (Oxygen) from
within the area in which it is used. Failure to provide adequate combustion
and ventilation air will result in asphyxiation, carbon monoxide poisoning,
bodily injury or death.
SAFETY INFORMATION
WARNING
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep combustibles such as;
building materials, paper or cardboard a safe distance away from the heater as
recommended by these instructions. Never use the heater in spaces which
contain products such as; gasoline, solvents, paint thinners, dust particles,
volatile or airborne combustibles or any unknown chemicals. This is an
unvented portable heater. It uses air (Oxygen) from the area in which it is
used. Adequate combustion and ventilation air must be provided. Bulk fuel
storage should be a minimum of 25 feet from heater.
WARNING
DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUGHLY UNDERSTAND THESE
SAFETY AND OPERATING INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with this
heater can result in death, serious bodily injury, property loss or damage
from the hazards of fire, soot production, explosions, burns, asphyxiation or
carbon monoxide poisoning. Only persons who can read and understand these
instructions should use or service this heater.
WARNING
DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED.
WARNING
DO NOT START THE HEATER WHEN THE CHAMBER IS HOT.
WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
MASSACHUSETTS RESIDENTS: Massachusetts state law prohibits the use of this heater in any building which is used in whole or in part for human habitation. Use of this heating device in Massachusetts requires local fire department permit (M.G.L.C. 148, Section 10A).
NEW YORK CITY RESIDENTS: The New York City Fire Code prohibits the storage, handling and use of kerosene fueled heaters for space heating. Any person violating that provision may be punished by a fine up to $10,000 and a term of imprisonment of up to 6 months.
THE INSTALLATION OF THIS HEATER SHALL COMPLY WITH THE REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION.
Look for this icon throughout the manual for helpful tips on how to assemble, use and clean your OFR heater.
WARNING
RISK OF INDOOR WARNING AIR POLLUTION!
The products described in this manual are kerosene direct-fired, forced air heaters. Kerosene forced air heaters are primarily intended for use for temporary heating of buildings under construction, alteration or repair. Directfired means that all of the combustion products of the heater enter the heated space. This appliance is rated at 98% combustion efficiency, but does produce small amounts of carbon monoxide.
DANGER
CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
Carbon monoxide is toxic. Humans can tolerate only small amounts of carbon monoxide and so precautions should be taken to provide proper ventilation. Failure to provide proper ventilation in accordance with the instructions in this manual can result in death.
People with breathing problems should consult a physician before using this heater. Early signs of carbon monoxide poisoning resemble the flu. Symptoms of improper ventilation/carbon monoxide poisoning are:
Headache • Dizziness • Nausea • Dry Mouth
Sore Throat • Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater serviced and check for proper
ventilation. Some people are more affected by carbon monoxide than others.
These include: pregnant women, those with heart or lung problems, anemia or
those under the influence of alcohol or at high altitudes.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY FOR: The temporary heating of adequately ventilated buildings or structures under construction, alteration or repair! Provide at least a three square foot (2,800 sq cm) opening of outside air for every 100,000 Btu/Hr (29 kW) heater rating. Refer to “Ventilation” on page 7 for further instructions.
WARNING
RISK OF ELECTRIC SHOCK!
ALWAYS use only the electrical power (voltage and frequency) specified on
the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly exposed to water
spray, rain, dripping water, or wind.
NEVER use fuels such as gasoline, benzine, paint thinners or other oil
compounds in this heater.
NEVER refill the heater’s fuel tank while the heater is operating or
still hot. This heater is EXTREMELY HOT while in operation.
NEVER block air outlet (front).
NEVER use duct work in front of heater.
NEVER move or handle heater while still hot.
WARNING
RISK OF BURNS, FIRE AND EXPLOSION!
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
| 80-OFR-B| 125-OFR-B
Top| 4 ft. (122 cm)| 6 ft. (183 cm)
Sides| 4 ft. (122 cm)| 6 ft. (183 cm)
Front| 8 ft. (244 cm)| 8 ft. (244 cm)
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat, once it is plugged in, it can
start at anytime in accordance with the thermostat setting.
WARNING
CAUTION! HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, ANIMALS,
CLOTHING AND COMBUSTIBLES AWAY FROM HEATER.
SPECIFICATIONS
Model # | 80-OFR-B | 125-OFR-B |
---|---|---|
Rating: Btu/Hr | 80,000 | 125,000 |
Fuel Consumption: Gal./Hr / L/Hr | 0.63 / 2.38 | 0.85 / 3.22 |
Fuel Tank Capacity: Gal. / L | 4 / 15.14 | 14 / 53 |
Max Operating Hours | 6 | 16 |
Volts: AC/Hz | 120 V / 60 Hz | 120 V / 60 Hz |
Amps | 3.15 | 3.15 |
Heating Area: ft.2 | 2000 | 3125 |
Specifications subject to change without notice.
FEATURES
80-OFR-B
125-OFR-B
WHAT’S IN THE BOX
80-OFR-B
Tools Needed:
- Phillips Head Screw Driver
Attach the handle while still in the box for easier unpacking (see Figures
1 and 2).
ASSEMBLY
80-OFR-B
IMPORTANT: INSTALL HEAT SHIELD BEFORE OPERATING YOUR 80-OFR-B HEATER
- Remove existing screws from shell ring on either side of heater (see Figure 3) .
- Line up holes on heat shield with holes in shell ring. Attach with screws removed in step 1 (see Figures 4 and 5).
WHAT’S IN THE BOX
125-OFR-B
ASSEMBLY
-
Slide axle through Wheel Frame and attach wheels, washers and nuts (see Figure 6).
-
Place main structure on wheel frame and fasten with long screws provided (see Figure 7).
-
Attach safety guard to front of heater with screws provided (see Figure 8).
-
Attach Radiant Visors to the top and bottom rear of the Radiant Cone Assembly using extra screws included.
-
Attach top safety guard using the two outer-most extra screws on the top of the radiant cone (see Figure 9).
Note: Save the box and packaging materials for future storage.
OPERATION
Fueling The Heater:
Kerosene
For optimal performance of this heater, it is strongly suggested that Kerosene
be used. Kerosene has been refined to virtually eliminate contaminants, such
as sulfur, which can cause a rotten egg odor during the operation of the
heater. Using diesel fuel can cause excess soot production. Do not use Bio-
Diesel as this fuel will damage your heater’s seals and filter.
CSA certified for use with K-1 kerosene, no. 1 & no. 2 diesel, JP8/Jet A Fuel, no. 1 and no. 2 fuel oil.
DANGER
NEVER REFUEL THIS HEATER WHILE IT IS HOT OR OPERATING. FIRE OR EXPLOSION
COULD RESULT.
CAUTION
NEVER FILL THE FUEL TANK INDOORS. AL- WAYS FILL THE TANK OUTDOORS. BE SURE
THAT THE HEATER IS ON LEVEL GROUND WHEN FUELING, AND NEVER OVERFILL THE TANK.
WARNING
DO NOT USE GASOLINE OR CRANKCASE DRAININGS.
-
NEVER use fuel such as, benzene, alcohol, white gas, camp
stove fuel, paint thinners, or other oil compounds in this heater. THESE ARE VOLATILE FUELS THAT CAN CAUSE A FIRE OR EXPLOSION. -
NEVER store Kerosene in the living space. Kerosene should be stored in a well ventilated area outside the living area.
-
NEVER store Kerosene in direct sunlight or near a source of heat.
-
NEVER use Kerosene that has been stored from one season to the next. Kerosene deteriorates over time. OLD Kerosene WILL NOT BURN PROPERLY IN THIS HEATER.
NOTE: Kerosene should only be stored in a blue container that is clearly marked “Kerosene.” Never store Kerosene in a red container. Red is associated with gasoline.
Ventilation:
DANGER
CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
- Risk of indoor air pollution and Carbon Monoxide Poisoning. Use heater only in well ventilated areas.
- Refer to Safety Information on pages 2-3 for information about Carbon Monoxide Poisoning.
- ALWAYS provide a fresh air opening in the heated space of
at least 2,800 square centimeters (3 sq. ft) for each 100,00 Btu/Hr. (29 kW) of heater output. Provide a larger opening if more heaters are being used.
Minimum Ventilation Opening Needed
80-OFR-B|
125-OFR-B
2.4 ft.2
| 3.75 ft.2
2230 cm2|
3484 cm2
Starting the Heater (Ignition):
- Fill the tank with Kerosene or other approved fuel until needle on fuel gauge points to “F”.
- Replace fuel cap and tighten firmly.
- Connect the heater to a three prong (grounded) power source. You must use a three prong (grounded) extension cord that is at least 1.8 meters long and is a minimum of 14 AWG rating.
NOTE: On first ignition or after refueling, you may hear a grinding sound
just before ignition. This is the fuel pump removing the air from the fuel
line. Your heater will start up within seconds. If it does not start repeat
start-up procedures with fuel gauge reading at least 1/2 tank.
NOTE: Smoking may occur on first ignition.
NOTE: The electrical components of these heaters are protected by a fuse
mounted in the PC board. If the heater fails to ignite, check this fuse first
and replace if necessary. Also check the power source to be sure the proper
voltage is being provided to the heater.
- Complete steps 1-3 above.
- Push the power switch to the “ON” position. The power indicator lamp will light and heater will ignite (see Figure 10)
Stopping the Heater (Cool Down):
- Turn the power switch to the “OFF” position. Combustion will stop and the Cooling Cycle will begin.
- 80-OFR-B: approx. 5 mins
- 125-OFR-B: approx 3 mins
When the Cooling Cycle is complete the fan will stop running and it will be safe to unplug the heater.
NOTE: Unplugging the heater before the Cooling Cycle has been completed may cause overheating, possible damage to the heater and heat plate.
WARNING
DO NOT disconnect heater from power source before cooling cycle has been
completed.
Restarting the Heater:
- Wait ten seconds after Cooling Cycle has been completed.
- Follow all start-up procedures above.
Electrical Outlet (80-OFR-B Only):
-
Never plug an appliance with more than a 5 amp rating into this outlet (see Figure 11).
-
Always keep outlet covered when not in use.
MAINTENANCE
Long Term Storage:
-
Unscrew the fuel cap.
-
Using an approved siphon, remove the Kerosene or diesel. (For the 125-OFR, drain the Kerosene or diesel by removing the drain bolt found under the tank.)
-
Using a small amount of Kerosene or diesel, rinse and swirl the fuel inside the fuel tank
NOTE: NEVER MIX WATER WITH FUEL. It will cause rust inside the tank. -
Empty the tank completely.
IMPORTANT: Never store leftover Kerosene between seasons, using old fuel can damage heater.
Store Heater in a dry, well ventilated area.
- Be sure that the storage area is free of dust and corrosive vapors. Repack the heater in the original packaging and keep user’s manual in an easily accessible place.
WARNING
Never service heater while it is plugged in or hot!
Service:
DO NOT TAMPER WITH THE UNIT. HAVE AN EXPERIENCED SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS.
We suggest following a maintenance schedule as follows:
TIP: Follow the long term storage instructions to flush the tank.
FUEL / FUEL TANK:
Flush tank every 200 hours of operation or as needed. DO NOT flush with water,
use fresh Kerosene only.
SPARK PLUG:
Clean and re-gap every 600 hours of operation or replace as needed. After
removing the Spark Plug, clean the terminals with a wire brush.
Re-gap the terminals to 0.140” (3.5 mm) (see Figure 12)
FAN BLADES:
The fan blades should be cleaned at least once per heating season, depending
on conditions. Remove all accumulated dust and dirt with a burst of condensed
air (see Figure 13).
PRESSURE ADJUSTMENTS:
Proper pressure is dependent on the fuel type the unit will be running. When
smoking or non-ignition occurs, remove the lower panel. Locate the Phillips
screw with a nut on the fuel pump to the left of the fuel line. There is a
small “P” next to the pressure screw. The ideal pressure is 112 psi (7.9
kg/cm2).
If you are experiencing smoking or fuel dripping from the unit , turn the screw clockwise 1/8 to 1/4 of a turn to increase the fuel pressure until the unit is operating properly.
If you are experiencing extended flames from the front of the unit, turn the screw 1/8 to 1/4 of a turn counterclockwise to reduce the air pressure until the unit is operating properly.
NOZZLES:
Nozzles should be cleaned or replaced at least once per heating season.
Contaminated fuel could make this necessary immediately. To clean dirt from
nozzle, blow compressed air through nozzle front. It may be necessary to soak
nozzle in clean Kerosene or diesel to help loosen any particles (see Figure
14a and 14b).
80-OFR-B Nozzle
125-OFR-B Nozzle
PHOTOCELL:
The photocell should be cleaned at least once per heating season or more
depending on conditions. Use a cotton swab and water or alcohol to clean the
lens of the photocell.
Be certain to reinstall the photocell in proper position as shown below (see
Figure 15).
FILTERS:
The fuel filter and oil filter should be cleaned at least twice per heating
season by rinsing it in clean Kerosene or diesel. Contaminated or old fuel
could make cleaning necessary immediately.
WIRING DIAGRAMS
80-OFR-B
125-OFR-B
TROUBLESHOOTING GUIDE
Problem
| Possible Cause|
Solution
---|---|---
Heater fires, but shuts down after a short period of time.|
- Dirty Fuel Filter.
- Nozzle Dirty.
- Photocell Dirty.
- Photocell not installed properly.
- Photocell Defective.
- Improper electrical connection between Circuit Board and Photocell.
- Cooling Fan is obstructed
- Improper pressure.
|
- Clean/replace Fuel Filter.
- Clean/replace Nozzle
- Clean/replace Photocell .
- Adjust Photocell position.
- Replace Photocell.
- Check wiring connections
- Check to be sure cooling fan is not obstructed.
- Adjust pump pressure.
Heater will not operate, or motor runs for short time.|
- No Kerosene/ diesel in fuel tank.
- Corroded Spark Plug or incorrect plug gap.
- Dirty Fuel Filter.
- Dirty Nozzle.
- Moisture in Fuel/Fuel Tank.
- Improper electrical connection between Transformer and Circuit Board.
- Transformer Wires not connected to Spark Plug.
- Defective Transformer.
|
- Fill tank with fresh Kerosene/ diesel.
- Clean/replace Spark Plug.
- Clean/replace Fuel Filter.
- Clean/replace Nozzle.
- Rinse out fuel tank with clean fresh Kerosene/ diesel.
- Inspect all electrical connections.
- Re-attach Transformer wires to Spark Plug.
- Replace Transformer.
Fan does not operate when heater is plugged in and Operating Switch is in the “ON” position.|
- Broken electrical connection between Circuit Board and motor.
- Not enough amps available to power heater.
|
- Inspect all electrical connections on Wiring Diagrams.
- Use a new extension cord or try another electrical socket.
Heater makes grinding noise.| Air in fuel pump.|
- Sound will stop after 3 seconds. If grind-ing sound continues, add fuel to tank.
Heater does not turn on and the lamp is not lit.|
- Temperature limit sensor has over- heated.
- No electrical power.
- Fuse break down.
- Improper electrical connection between Temperature Limit Sensor and Circuit Board.
|
- Push Operating Switch to “OFF” and allow heater to cool for 5 minutes. Push Operating Switch back to “ON”.
- Check power cord and extension cord to insure of proper connection. Test power supply.
- Check/replace Fuse.
- Inspect all electrical connections.
Poor combustion and / or soot production.|
- Pump Pressure.
- Poor fuel quality.
|
- Be sure pump pressure is adjusted correctly.
- Be sure Kerosene/ diesel is not old or contaminated.
EXPLODED VIEW
80-OFR-B
PARTS LIST:
80-OFR-B
Item # | Description | Part Number |
---|---|---|
1 | Fuel Filter | 75-023-0285 |
2 | Fuel Line | 75-024-0740 |
3 | Fuel Gauge | 75-022-0210 |
4 | Fuel Cap | 70-006-0140 |
5 | Cooling Fan Housing / Cooling Fan Housing Panel | 75-011-0685 / 75-011-0690 |
6 | Electric Pump | 75-027-0650 |
7 | Ignitor | 70-037-0350 |
8 | Main PCB Assembly | 75-025-0490 |
9 | Tip-Over Sensor | 75-051-0200 |
10 | Cooling Motor Assembly | 75-047-0250 |
11 | Cooling Fan | 75-047-0200 |
12 | Handle | 75-001-0060 |
13 | Temperature Limit Switch | 75-040-0100 |
14 | Heat Plate | 75-012-0600 |
15 | Shell Ring | 75-011-0650 |
16 | Safety Guard | 75-012-0310 |
17 | Burner Body | 75-036-0180 |
18 | Spark Plug | 75-075-0200 |
19 | Burner Blade | 75-036-0120 |
20 | Nozzle | 75-036-0460 |
21 | Nipple | 75-040-0610 |
22 | Diffusion Cap | 42-300-0010 |
23 | Blower Motor Assembly | 75-045-0200 |
24 | Photocell | 72-038-0200 |
25 | Return Pipe | 75-055-0100 |
26 | Return Hose | 75-055-0205 |
27 | Fuel Pressure Gauge | 70-028-0200 |
EXPLODED VIEW
125-OFR-B
PARTS LIST:
125-OFR-B
Item # | Description | 125-OFR-B |
---|---|---|
1 | Fuel Gauge Assembly | 72-022-0100 |
2 | Fuel Cap | 70-006-0130 |
3 | Wheel | 70-041-1400 |
4 | Axle | 72-041-0200 |
5 | Drain Bolt | 72-002-0220 |
6 | Height Adjustment Knob | 72-042-0500 |
7 | Return Fuel Line | 72-023-0290 |
8 | Intake Fuel Line | 72-023-0280 |
9 | Fuel Filter Assembly | 72-020-0200 |
10 | Fuel Pump | 72-027-0100 |
11 | Main PCB and Fuse | 72-025-0450 |
12 | Tip Over Sensor | 75-051-0200 |
13 | Power Switch | 72-012-0120 |
14 | Back Cover | 72-013-0110 |
15 | Panel sub-PCB | 72-014-0100 |
16 | Blower Motor Assembly | 72-045-0100 |
17 | Photocell | 72-038-0200 |
18 | Spark Plug | 75-075-0200 |
19 | Burner Body | 72-035-0210 |
20 | Nozzle | 72-036-0100 |
21 | Diffusion Cap | 72-036-0210 |
22 | Ignitor | 70-037-0350 |
23 | Temperature Overheat Sensor | 72-040-0100 |
24 | Safety Guard | 72-012-0200 |
25 | Front Frame | 38-110-0010 & 38-110-0020 |
26 | Top Safety Guard | 72-012-0250 |
27 | Radiant Visors | 72-012-0220 |
28 | Radiant Cone Gaskets | 72-035-0630 |
29 | Burner Housing Assembly | 72-035-0615 |
LIMITED WARRANTY
Pinnacle Climate Technnologies, Inc. warrants this heater to the original retail purchaser only, to be free from defects in material and workmanship for a period of one (1) year from the date of initial purchase. This product must be properly installed, maintained and operated in accordance with the instructions provided.
Pinnacle Climate Technnologies, Inc. requires reasonable proof of your date of purchase from an authorized retailer or distributor. Therefore, you should keep your sales slip, invoice or cancelled check from the original purchase. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service within the warranty period, and which Pinnacle Climate Technnologies, Inc. shall determine at its reasonable discretion.
This warranty does not apply to products purchased for rental use.
This Limited Warranty does not cover any failures or operating difficulties due to normal wear and tear, accident, abuse, misuse, alteration, misapplication, improper installation or improper maintenance and service by you or any third party. Failure to perform normal and routine maintenance on the heater, shipping damage, damage related to insects, birds or animals of any kind, and damage due to weather conditions are also not covered. In addition, the Limited Warranty does not cover damage to the finish, such as scratches, dents, discoloration, rust or other weather damage, after purchase.
All transportation costs for the return of damaged product or parts will be the responsibility of the purchaser. Upon receipt of damaged item, Pinnacle Climate Technnologies, Inc. will examine the item and determine if defective. Pinnacle Climate Technnologies, Inc. will repair or replace and return the item, freight pre-paid.
If Pinnacle Climate Technnologies, Inc. finds the item to be in normal operating condition, or not defective the item will be returned freight collect. This Limited Warranty is in lieu of all other express warranties. Pinnacle Climate Technnologies, Inc. disclaims all warranties for products that are purchased from sellers other than authorized dealers or distributors.
AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS WARRANTY EXPIRES, Pinnacle Climate Technnologies, Inc. DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR APPLICATION. FURTHER, Pinnacle Climate Technnologies, Inc. SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Pinnacle Climate
Technnologies, Inc. assumes no responsibility for any defects caused by third parties. This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to you.
Pinnacle Climate Technnologies, Inc. does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return or replacement of its equipment, and no such representations are binding on Pinnacle Climate Technnologies, Inc.
Always be sure to specify the model number and serial number when making any claim with Pinnacle Climate Technnologies, Inc. For your convenience, use the space provided below to list this information.
Locating Your Serial Number:
Your serial number can be found on a blue label on the left side cover. It will begin with the letter “S” followed by 9 digits.
For Example: S160901126. Have your Serial Number ready before calling
customer service at 800-641-6996.
Model #:____
Serial #:____
Date of Purchase: ____
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>