UNI-T UT661C/D Pipeline Blockage Detector User Manual
- June 3, 2024
- UNI-T
Table of Contents
UNI-T UT661C/D Pipeline Blockage Detector User Manual
Introduction
Blockages and obstructions in pipelines can result in significant losses in
revenue and severe disruption to operations. It is often critical to correctly
identify the location of any blockages or obstructions to allow swift remedial
actions to be taken.
UT661C/D can quickly locate any blockages or obstructions to avoid large scale
overhaul. It is able to penetrate up to 50cm wall with accuracy of ±5cm.
Cautions
- Turn off the device after use.
- Pull out the probe from the pipe before clearing the pipe.
- Detecting distance may be shortened slightly for detecting steel pipe.
- If the green LEDs of transmitter and receiver are lit normally but no voice is present during detection, please replace the probe.
Power On/Off Transmitter
Long press power button for 1s to power on the device, and short/long press the same button to power off the device. The device will automatically power off after 1 hour. Long press power button for more than 10s to compulsively power off the device.
Receiver : Rotate the power switch clockwise until the power indicator turns on to power on the device. And rotate the power switch anticlockwise until the power indicator turns off to power off the device. The device will automatically power off after 1 hour.
Inspection before Use
Turn on both the transmitter and receiver, rotate the power switch of the receiver clockwise to the end and place it closer to the probe, if the buzzer goes off, it is in well-condition. If not, take off the plastic cap of the probe to check if it is broken or short circuited.
Detection
Note: Please hold the handle tightly and rotate the wire coil when setting out or collecting the wire.
Step 1: Insert the probe into the pipe, extend the probe to the longest
length possible, to where the blockage is located.
Step 2: Turn on the transmitter and receiver, set the sensitivity of the
receiver to MAX by rotating the power switch, then use the receiver to scan
from the probe entrance, when the buzzer goes off strongest, mark the point
and pull out the probe.
Sensitivity Adjustment
Users can turn the power switch to increase the sensitivity for blockage
detection. Users can use high sensitivity position to locate the approximate
range then lower the sensitivity to precisely locate the blockage point:
Increase sensitivity : rotate the power switch clockwise; Decrease
sensitivity: rotate the power switch anticlockwise.
Power Indicator
LED | Power |
---|---|
Solid green | Full power; when charging: fully charged |
Flashing green | Low power, please charge |
Solid red | Charging |
- Charge the device by using standard 5V ‘IA charger with micro USB adapter.
- If not being used for a long time, please fully charge the device and store it in a safe location.
- It is suggested to charge the device once per half year to protect the battery of the device and lengthen lifetime.
Demonstration
Probe Replacement
Specification
Functions | Basic Accuracy |
---|---|
UT661C | UT661D |
Transmitter | √ |
Signal wire | 25m |
Receiver | √ |
Maximum detection depth | 50cm |
Transmitter current | Shutdown current. < 2uA, operating current: 230-310mA |
Receiver current | Shutdown current- < 2uA, standby current- < 40mA, maximum |
operating current: 150-450mA (1cm distance)
Charging current| 450-550mA
Sound (1cm distance)| >93dB
Sound (0.5cm distance)| >75dB
Battery duration| 10 hours
Operating temperature and humidity| -20″C-60 C 10-80%RH
Measurable pipe materials| Plastic pipes, metal pipes
Buzzer|
Flash| √
Low battery indication| √
√
IP rating| IP 67 (probe)
General Characteristics
Transmitter battery| Built-in lithium battery (3.7V 1800mAh)
Receiver battery| Built-in lithium battery (3.7V 1800mAh)
Product color| Red + gray
Standard accessories| Charging cable, probe kit
Standard individual packing| Gift box, user manual
Standard quantity per carton| 5pcs
Standard carton measurement| 405x90x350mm
Note: The measurement distance refers to the maximum effective distance that can be detected when there is no obstruction between the transmitter and the receiver. If there is a metal or wet object between them, the effective distance will be reduced.
NO. | Item | Quantity | Remarks |
---|---|---|---|
1 | Transmitter | 1 | |
2 | Receiver | 1 | |
3 | Charging cable | 1 | |
4 | Probe kit | 1 | Protective cap, probe, tin |
wire, shrinkable tube
5| Instant glue| 1|
6| User manual| 1|
7| Lithium batteries| 2| Built-in batteries for transmitter and receiver