BITMAIN ANTRACK V1 Cooling Mining Rack Instructions

June 1, 2024
BITMAIN

BITMAIN ANTRACK V1 Cooling Mining Rack

Specifications

  • Model: ANTRACK V1
  • Capacity: 4 units ANTMINER (S21 Hyd.)
  • Maximum Load: 24 kW

Product Glance

  • Hardware configuration:
    • Size (WidthHeightDepth): 60020001000 mm
    • Net weight (w/o miner): 300 kg
    • Network connection mode: RJ45 Ethernet 10/100M
  • Power supply:
    • AC input voltage, Volt: 380~415V AC
    • AC input frequency range, Hz: 50~60
    • Maximum power supply AC input current, Amp: 80
  • Fan:
    • Rated power, W: 106
    • Noise, dBA@1m: 68
    • Size (LengthHeightThickness), mm: 28028080
  • Pump:
    • Rated power, W: 750
    • Noise, dBA@1m: 55
    • Size (LengthWidth Height), mm: 360210268
  • Plate heat exchanger:
    • Maximum heat exchange power, kW: 30
    • Size (LengthWidth Height), mm: 30510664
    • Diameter of water pipe connector, mm: DN25
  • Environment requirements:
    • Temperature Range: 15~45°C
    • Water flow, L/min: 32.0~40.0
    • Water pressure, bar: 3.5
    • Working fluid: Deionized water/Pure water
    • Liquid PH: 8.5~9.5
    • Operation humidity(non-condensing), RH: 10~90%

Product Usage Instructions

Power Supply Connection
Connect the power supply to the designated AC input voltage and frequency range mentioned above.

Network Connection Setup
Use an RJ45 Ethernet cable to connect the product for network access.

Frequently Asked Questions (FAQ)

What should I do if the water conductivity is above 100 s/cm?
If the water conductivity exceeds 100 s/cm, the fluid must be replaced to prevent damage to the system.

Specification

Product Glance Value
Model ANTRACK
Version V1
Capacity 4 units ANTMINER (S21 Hyd.)
Maximum load, kW 24
Detailed Characteristics Value
--- ---

Hardware configuration
Size (WidthHeightDepth), mm| 60020001000
Net weight (w/o miner), kg| 300
Network connection mode| RJ45 Ethernet 10/100M
Power supply
Power supply AC input voltage, Volt (1-1)| 380~415V AC
Power supply AC input frequency range, Hz| 50~60
Maximum power supply AC input current, Amp (1-2)| 80
Fan
Rated power, W| 106
Noise, dBA@1m| 68
Size (LengthHeightThickness), mm| 28028080
Pump
Rated power, W| 750
Noise, dBA@1m| 55
Size (LengthWidth Height), mm| 360210268
Plate heat exchanger
Maximum heat exchange power, kW| 30
Size (LengthWidth Height), mm| 30510664
Diameter of water pipe connector, mm| DN25
Environment requirements
Ambient temperature, °C| 15~45
Water flow, L/min| 32.0~40.0
Water pressure, bar| ≤3.5
Working fluid(1-3)| Deionized water/Pure water
Liquid PH| 8.5~9.5
Storage temperature, °C| -20~70
Operation humidity(non-condensing), RH| 10~90%

Notes:

  1. Caution: Wrong input voltage may cause server damaged.
  2. Three-phase AC input.
  3. If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BITMAIN User Manuals

Related Manuals