MEAN WELL NGE30 Series 30W AC-DC Reliable Wall-Mounted Interchangeable Type Green Adaptor Owner’s Manual
- June 1, 2024
- MEAN WELL
Table of Contents
30W AC-DC Reliable Wall -mounted Interchangeable Type Green Adaptor
NGE30 series
NGE30 Series 30W AC-DC Reliable Wall-Mounted Interchangeable Type Green
Adaptor
Features
- MEAN WELL Patent Application Number: 202330347779.4
- Interchangeable AC plugs [I-Type)
- Global certificates in multi-fields (ITE 62368-1. Medical 60601-1. Household 60335-1.Industnal 61558-1/-2-16)
- 80~264Vac Universal AC input
- Ultra slimi380mm}
- No load power consumption< 0.075W
- Energy efficiency Level ‘|
- Class II power (no earth pin)
- Protections: Short circuit / Overload / Over voltage
- Pass LPS
- Extremely low leakage current <100uA
- -301 -+701 wide range working temperature
- Various DC plug quick adapter accessory available (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf)
- 3 years warranty
Applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments
- Medical devices
- Household devices
GTIN CODE
MW Search:
https://www.meanwell.com/serviceGTIN.aspx
Description
NGE30 is a highly reliable, 30W wall-mounted style single-output green
adaptor series, which is compact and convenient for carry. This product is
equipped with 5 types of interchangeable AC plug (European, USA,U.K.
,Australian and China type) that makes it very suitable for travel use. NGE30
is a Class I] power unit (no FG), accepting the input range from 80VAC to
264VAC that it can satisfy the demands for various types of electrical
devices.
With the working efficiency up to 91.5% and the extremely low no-load power
consumption below 0.075W, NGE3O is compliant with the latest USA energy
regulation EISA 2007/DoE, Canada NRCan,Australia and New Zealand MEPS,EU ErP
and CoC versionS. The supreme feature allows the adaptor to save the energy
when it is under either the operating mode or the standby mode. The entire
series is approved for ITE, medical, household and industrial appliance safety
regulations; moreover, it adopts the 94V-0 flame retardant plastic case that
it can effectively prevent users from electric hazard.
Model Encoding
SPECIFICATION
ORDER NO.| NGE3005-P1J| NGE3009-P1J| NGE3012-P1J| NGE3015-P1J| NGE3018-P1J|
NGE3024-P1J| NGE3048-P1J
---|---|---|---|---|---|---|---
= I, U, E
OUTPUT| DC VOLTAGE Note.2| 5V| 9V| 12V| 15V| 18V| 24V| 48V
RATED CURRENT| 4A| 3.33A| 2.5A| 2A| 1.66A| 1.25A| 0.63A
CURRENT RANGE| 0 ~ 4A| 0 ~ 3.33A| 0 ~ 2.5A| 0 ~ 2A| 0 ~ 1.66A| 0 ~ 1.25A| 0 ~
0.63A
RATED POWER| 20W| 30W| 30W| 30W| 30W| 30W| 30W
RIPPLE & NOISE (max.) Note.3| 100mVp-p| 100mVp-p| 120mVp-p| 150mVp-p|
180mVp-p| 240mVp-p| 240mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±2.0%
LINE REGULATION Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD
REGULATION Note.6| ±5.0%| ±5.0%| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±2.0%
SETUP, RISE, HOLD UP TIME| 1500ms, 30ms, 30ms / 230VAC
3000ms, 30ms, 10ms / 115VAC at full load
INPUT| VOLTAGE
RANGE Note.7| 80 ~ 264VAC
113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 82.5%| 87.5%| 88.5%| 87%| 88%| 88.5%| 91.5%
AC CURRENT| 1A / 115VAC 0.6A / 230VAC
INRUSH CURRENT (max.)| COLD START 35A / 115VAC 70A / 230VAC
LEAKAGE CURRENT (max.)| Touch current < 100uA (rms) @264VAC
PROTECTION| OVERLOAD| 110% ~ 150% rated output power
Protection type : 5~24V Hiccup mode, recovers automatically after fault
condition is removed.
48V Shut down and latch off o/p voltage, re-power on to recover.
OVER VOLTAGE| 110% ~ 140% rated output voltage
Protection type : Clamp by zener diode
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0 ~ 45℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z
axes
SAFETY & EMC (Note. 8)|
SAFETY STANDARDS
| CB IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16, IEC60335-1;
UL UL62368-1, CSA C22.2 NO. 62368-1, ANSI/AAMI ES60601-1(3.2 Version),
CAN/CSA-C22.2 NO.60601-1; ANSI/AAMI ES60601-1-11, CAN/CSA-C22.2
NO.60601-1-11(for U Type only)
DEKRA BS EN/EN62368-1, BS EN/EN60601-1/-1-11, BS EN/EN61558-1/-2-16, BS
EN/EN60335-1; PSE J62368-1; BSMI CNS15598-1;
RCM AS/NZS 61558-1/-2-16; EAC TPTC004;
CCC GB4943.1 approved.
(Please refer to next page for more details)
WITHSTAND VOLTAGE| I/P-O/P:4000VAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted emission| BS EN/EN55032(CISPR32)/EN55011 , FCC Part15 , CNS15936,
GB/T 9254.1-2021| Class B
Radiated emission| BS EN/EN55032(CISPR32)/EN55011 , FCC Part15 ,
CNS15936, GB/T 9254.1-2021
| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
EMC IMMUNITY| Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 3, 15KV air; Level 2, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 2, 3V/m
EFT bursts| BS EN/EN61000-4-4| Level 2, 1KV
Surge susceptibility| BS EN/EN61000-4-5| Level 3, 1KV/L-N
Conducted susceptibility| BS EN/EN61000-4-6| Level 2, 3V
Magnetic field immunity| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage dips , interruption| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip
25 periods,
>95% interruptions 250 periods
OTHERS| MTBF| 1078.6 Khrs min. MIL-HDBK-217F (25℃) 7587.5 Khrs min.
Telcordia TR/SR-332(Bellcore) (25℃)
DIMENSION| 623065mm (LWH)
PACKING| MAIN BODY| 148g; 60pcs/ 10.5Kg / 0.94CUFT for NGE30Ixx/Uxx-P1J
162g; 45pcs/ 9.2Kg / 1.06CUFT for NGE30Exx-P1J
AC PLUGS| Refer to Page 3
DC OUTPUT CONNECTOR| PLUG| See page 6~7 ; Other type available by customer
requested
CABLE| See page 6~7 ; Other type available by customer requested
NOTE
| 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH
ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50%
load.
3. Ripple & noise are measured at 20MHz by using a 12″ twisted pair
terminated with a 0.1μF & 47μF capacitor. 4.Tolerance: includes set up
tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 0% to 100% rated load
7. Derating may be needed under low input voltage. Please check the derating
curve for more details.
8. The power supply is considered as an independent unit, but the final
equipment still need to re-confirm that the whole system complies with the EMC
directives. For guidance on how to perform these EMC tests, please refer to
EMI testing of component power supplies.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
9. Design meet US DoE Level VII (from Docket number EERE-2020-BT-STD-0006).
※ Product Liability Disclaimer:For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
Interchangeable AC Plug Specifically for NGE12/18/30/45/65/90 (I-Type)
Order NO. | NGE30Exx-P1J | NGE30Uxx-P1J | |
---|---|---|---|
AC plug | Interchangeable Type | Non-Interchangeable Type | |
EU | US | UK | AU |
Certificate |
| |
AC Plugs Accessory (Sold Seperately)
MW’s order NO. | Per Unit | Per Bag | Per Carton |
---|---|---|---|
Q’Ty | Q’Ty | G.W. | |
AC PLUG-EU4 | 30 pcs | 300 pcs (10 bags) | |
AC PLUG-US4 | 30 pcs | 300 pcs (10 bags) | |
AC PLUG-UK4 | 30 pcs | 300 pcs (10 bags) | |
AC PLUG-AU4 | 30 pcs | 300 pcs (10 bags) | |
AC PLUG-CN4 | 30 pcs | 300 pcs (10 bags) | |
AC PLUG-MIX4 |
| 30 pcs (5 Types6 mixed bags)| 300 pcs (5 Types6 mixed bags) (10 bags)| 5.78Kg
Interchangeable AC Plug Installation Steps (Convertible with I Type only)
Step1 | Step2 |
---|---|
Slide in AC converter along the guided rail between the metal prongs until it is locked in (with a “click” sound).| Check if the new plug type is stable and correct before use.
Note:
- NGE30I main body unit and AC inlet plug should be ordered separately.
- NGE30I needs to be used along with one of the AC inlet plug (EU,US,UK,AU,CN).
Mechanical
Specification
※ Cable connection DC Output
Plug
◎ Standard plug: P1J◎ DC plug changeable through:
- Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
- Quick adapter accessory (sold separately without MOQ)
Please refer to below table and online selection guide :
Example quick adapter accessory:
https://www.meanwell.com/upload/pdf/DC_plug.pdf◎ Optional DC plug: (Available in customized cable
or quick adapter)
Tuning Fork Style | Type No. | A | B | C | Quick Adapter Accessory |
---|---|---|---|---|---|
OD | ID | L | |||
P1I | 5.5 | 2.1 | 9.5 | Available |
(Current rating: 7.5A max.)
P1L| 5.5| 2.5| 9.5
P1M| 5.5| 2.5| 11.0
| P1IR| 5.5| 2.1| 9.5
P1JR| 5.5| 2.1| 11.0
P1LR| 5.5| 2.5| 9.5
P1MR| 5.5| 2.5| 11.0
Barrel Style| Type No.| A| B| C| None
OD| ID| L
| | P2I| 5.5| 2.1| 9.5
P2J| 5.5| 2.1| 11.0
P2L| 5.5| 2.5| 9.5
P2M| 5.5| 2.5| 11.0
| P2IR| 5.5| 2.1| 9.5
P2JR| 5.5| 2.1| 11.0
P2LR| 5.5| 2.5| 9.5
P2MR| 5.5| 2.5| 11.0
Lock Style| Type No.| A| B| C| None
OD| ID| L
| P2S(S761K)| 5.53| 2.03| 12.06
P2K(761K)| 5.53| 2.54| 12.06
P2C(S760K)| 5.53| 2.03| 9.52
P2D(760K)| 5.53| 2.54| 9.52
Min. Pin Style| Type No.| A| B| C| Quick Adapter Accessory
---|---|---|---|---|---
OD| ID| L
| P3A| 2.35| 0.7| 11.0| Available (Current rating: 5A max.)
P3B| 4.0| 1.7| 11.0
P3C| 4.75| 1.7| 11.0
Center Pin Style| Type No.| A| B| C| D| Available
(Current rating: 7.5A max.)
OD| ID| L| Center Pin
| P4A| 5.5| 3.4| 11.0| 1.0
P4B| 6.5| 4.4| 11.0| 1.4
P4C| 7.4| 5.1| 11.0| 0.6
Min. DIN 3 Pin with Lock (male)| Type No.| Pin Assignment| Available
(Current rating: 7.5A max.)
PIN No.| Output
| R6B| 1| +Vo
2| -Vo
3| +Vo
Min. DIN 4 Pin with Lock (male)| Type No.| Pin Assignment| Available
(Current rating: 7.5A max.)
PIN No.| Output
| R7B| 1| +Vo
2| -Vo
3| -Vo
4| +Vo
Stripped and tinned leads| Type No.| Pin Assignment| None
PIN No.| Output
Length of Land L1 by request (MW’s standard length, L: __25 mm, L1: 10
mm)| by customer| 1 ( Ribbed )| +Vo
2 ( Letter )| -Vo
Installation Manual
Please refer to :
http://www.meanwell.com/manual.htmlhttps://www.meanwell.com/Upload/PDF/Adaptor_EN.pdf
Documents / Resources
| MEAN
WELL NGE30 Series 30W AC-DC Reliable Wall-Mounted Interchangeable Type Green
Adaptor
[pdf] Owner's Manual
NGE30 Series 30W AC-DC Reliable Wall-Mounted Interchangeable Type Green
Adaptor, NGE30 Series, 30W AC-DC Reliable Wall-Mounted Interchangeable Type
Green Adaptor, Reliable Wall-Mounted Interchangeable Type Green Adaptor,
Interchangeable Type Green Adaptor, Type Green Adaptor, Green Adaptor, Adaptor
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>