ACCURATE M9134ELR Motor Drive Electrified Latch Retraction Instructions
- June 1, 2024
- Accurate
Table of Contents
M9134ELR OPERATING INSTRUCTIONS
MOTOR DRIVE ELECTRIFIED LATCH RETRACTION
Rotating inside handle or using electronics simultaneously retract latch and
deadbolt (when extended).*
Latch bolt by key outside or using electronics, egress by handle inside.
Deadbolt manually projected by thumb turn inside or key outside.
Outside trim (if applicable) is always rigid.
FAIL SECURE OPERATION ONLY:
Latch retracts when power is applied.
Key Cylinder (by others) will override electronics to retract latch bolt and
deadbolt.
2 CONDUCTOR WIRE RUN
DISTANCE| WIRE GAUGE
125’| 22
200’| 20
350’| 18
500’| 16
800’| 14
1250’| 12
ELECTRICAL SPECIFICATIONS
Filtered and Regulated Power Supply
Voltage: 24VDC (21VDC-30VDC)
Current: 625mA MAX Inrush, 150mA MAX Holding
Non-polarized leads
- INDICATOR LIGHTS
*For applications requiring the deadbolt not to retract via electronics, please add DM Monitor and program access accordingly.
ONBOARD INDICATOR LIGHT ASSIGNMENTS
GREEN (POWER) | YELLOW (SENSOR)| RED (ERROR)| INDICATION|
POSSIBLE SOLUTION
Off| Off| Off| No Power.| Connect the wiring between the power supply and the
mortise lock.
On| On| Off| Normal Operation. The main latch bolt is retracted to the preset
retracted position. The device is allowed 2 attempts.|
On | Off| On| Error in operation. The main latch bolt did not retract to the
preset retracted position within 2 attempts.| Clear the jam condition
manually.
On| On| On| Error in operation. Without power being removed, the main latch
bolt unintentionally extended from the preset retracted position, and then the
main latch bolt did not retract back to the preset retracted position within 2
attempts.| Clear the jam condition manually.
On| Blink| On| Error in operation. The main latch bolt did not extend from the
preset retracted position when the power was last removed. The device will not
attempt a retraction.| Clear the jam condition manually.
On| Simultaneous Blink| Error in operation. The input voltage dropped below
the specification during operation.| Decrease the wire run or increase the
wire gauge.
On| Alternating Blink| Error in operation. An electronics fault was detected.|
An electronics replacement is required.
Maintain input power to the mortise lock and check the onboard indicator
lights.
Remove input power before attempting a solution.
1 Annie Pl, Stamford CT 06902 | 203.348.8865 | accuratelockandhardware.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>