SIGOR 4812001 Surface Mount Pendant Light Installation Guide

June 1, 2024
SIGOR

SIGOR 4812001 Surface Mount Pendant Light

Product Information

Specifications:

  • Brand: Sigor Licht GmbH
  • Model: Not specified
  • Compliance: RoHS compliant

Product Usage Instructions

Safety Instructions:
Before starting any work, please read and follow the installation and operating manual carefully. The installation of this luminaire must be carried out by a qualified electrician to ensure safety. Follow all safety and health regulations, especially VDE 0100 guidelines. Always isolate the relevant part of the system and check the luminaire for integrity before commissioning.

Assembly:
Mount the housing base on a level and solid foundation using the included mounting materials. Adjust as necessary for different surfaces. Disconnect the circuit and observe occupational safety measures. Shorten the 230V AC cable, strip insulation from the conductor ends, and connect them to the terminal block as instructed in the manual.

Lens Change:
To change the lens, follow these steps:

  1. Open the control lever of the terminal block.
  2. Insert the stripped ends of the live cable L and neutral conductor N into the terminal block.
  3. If connecting multiple 230V AC cables in parallel, add a third cable and connect it to the third terminal block.

Disposal:
Dispose of the luminaire properly at the end of its life by returning it to the dealer or an electronic waste collection point.
Do not dispose of it in household waste to comply with RoHS regulations.

FAQ:

Q: Can I replace the light source myself?
A: No, the light source of this luminaire should only be replaced by Sigor Licht GmbH, an authorized service technician, or a qualified person to avoid the risk of electric shock.

Q: What should I do in case of warranty claims?
A: In case of warranty claims, contact Sigor Licht GmbH at the provided address and contact information for assistance.

4812001 Nivo® Pendant Light Surface Mount 36° Black
4812101 Nivo® Pendant Light Surface Mount 36° White
4812201 Nivo® Pendant Light Surface Mount 50° Black
4812301 Nivo® Pendant Light Surface Mount 50° White

Before starting work

Please read and follow this installation and operating manual carefully. The installation of this luminaire must be carried out by an electrician for your safety. Follow safety and health regulations for all activities,especially the relevant selection of VDE 0100. Before starting the installation, isolate the relevant part of the system following the five safety rules. Check the luminaire for integrity before commissioning, only operate undamaged products!

Intended Use
The Nivo® pendant lights ensure protection class IP30 and are intended for mounting on solid and loadbearing surfaces indoors at ambient temperatures of -20 to +40°C with 220-230V 50Hz AC. The intended use also includes observing all information in this manual, especially the safety instructions.

Note: The luminaires are not intended to be covered with insulating material such as mineral wool. Any other use is considered improper and may lead to property or personal damage.

Non-user-replaceable light source
The light source of this luminaire may only be replaced by Sigor Licht GmbH or an authorized service technician or a similarly qualified person. (EN 60598-1 3.3.21)

Caution! Risk of electric shock.

Disposal
Sigor luminaires are RoHS compliant and should be returned to their dealer or an electronic waste collection point at the end of their life. Do not dispose of them in household waste.

Scope of delivery

  • Nivo® Pendant Light Surface Mount with 5 years Sigor functional guarantee
  • 2 screws, 2 anchors for concrete or masonry
  • 2 screws, 2 anchors for drywall
  • This installation and operating manual
  • Cotton gloves

Disclaimer
Note: In case of non-compliance with this manual and improper use, there is no warranty claim;
Sigor Licht GmbH assumes no liability in such cases.

Installation

  1. Mount the housing base on a level and solid foundation. Adjust the included mounting material if necessary for different surfaces.

  2. With mounting options on all installation boxes 68 mm.

  3. Disconnect the circuit, observe occupational safety! Shorten the 230V AC cable and remove 8 mm of insulation from the conductor ends of L and N.

  4. Open the control lever of the terminal block and insert the stripped ends of the live cable L and the neutral conductor N into the terminal block (Figure a). If 230V AC cables are connected in parallel, add a third AC cable and connect it to the third terminal block (Figure b).SIGOR-4812001-Surface-Mount-Pendant-Light-FIG- \(3\)SIGOR-4812001-Surface-Mount-Pendant-Light-FIG- \(4\)

  5. Connect the red and blue wires of the luminaire housing to the terminals of the base. Observe polarity: red to + and blue to –

  6. Insert the insert (b) into the housing base‘s recess (a), press down, and rotate with a right turn (c) about 20° until it clicks. The correct position is marked with arrows.

  7. To open, press the insert slightly down and continue turning about 20° counterclockwise from the lock. The insert can now be removed.
    Tip: Turn the insert to lock or unlock it before reaching the respective stop.

  8. Loosen the screws of the strain relief (a) and set the cable to the desired pendant length. Strip the conductor ends and crimp them with the included end sleeves.
    Lens Replacement

The lens insert (a) is held in the luminaire by three magnets; with a slight rotation of the lens insert in the luminaire (b), the magnets separate, and the lens insert (b) falls out.

Disposal Instructions according to ElektroG
„Owners of old devices must dispose of them separately from unsorted municipal waste. Old devices must not be disposed of with household waste but through special collection and return systems.
Owners of old devices must separate batteries and accumulators not enclosed by the old device, as well as lamps that can be removed from the old device without destruction, from the old device before handing it over to a collection point. This does not apply if old devices are handed over to public-law waste disposal authorities and are separated there for the purpose of preparing them for reuse. Owners of old devices from private households can hand them in free of charge at the collection points of public-law waste disposal authorities or at the collection points set up by manufacturers and distributors in accordance with the ElektroG.

An online directory of collection and return points can be found here: https://www.e-schrott-entsorgen.org/

Some old devices contain sensitive personal data, especially devices in information and communication technology such as computers and smartphones. It is in your own interest to ensure that you are responsible for deleting the data on the old de-vices to be disposed of. The symbol of a crossed-out dustbin on electrical and electronic equipment means that the device must be disposed of separately from unsorted municipal waste at the end of its service life.“

Warranty Conditions
The warranty is exclusively for consumers. Warranty protection applies only to products purchased within the Federal Republic of Germany. The warranty period begins on the invoice date.
If material or manufacturing defects in the goods you purchased arise during this period and affect the function of the product, we will provide you with a new, defect-free product as part of this warranty. This does not apply in the case of a battery performance fault.
In the event of a warranty claim, please contact us as the warranty provider:

Sigor Licht GmbH Phone: +49 2339 1261 0 Eichenhofer Weg 81 Email: [email protected] 42279 Wuppertal
Warranty claims are excluded for damage to the goods due to normal wear and tear and improper or non-intended use or treatment. A prerequisite for claiming warranty service is that you enable us to examine the warranty case (e.g., by sending the goods). If you send the goods for this purpose, please ensure that damage to the goods during transport is avoided through appropriate packaging. A copy of the invoice must be included with the goods shipment for the warranty claim to be reviewed, so we can verify whether the warranty period has been adhered to. Alternatively, you can send the copy of the invoice to us by email. We reserve the right to reject the warranty service if it cannot be determined whether the warranty period has expired.

There are no shipping costs for justified warranty claims. In this case, we will refund any shipping costs for the return of the defective goods and bear the costs of shipping a new, defect-free product to you.
Important Note: This warranty does not limit your statutory rights. Instead, the warranty promise is separate from the statutory warranty rights to which you are entitled free of charge.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SIGOR User Manuals

Related Manuals