Product Usage Instructions
Safety Instructions
Before starting any work, please read and follow the installation and
operating manual carefully. The installation of this luminaire must be carried
out by an electrician for safety reasons. Follow all safety and health
regulations, especially VDE 0100 guidelines.
Installation
- Switch off the corresponding circuit and disconnect the power supply indoors.
- Create a ceiling cutout with a diameter of 102 mm.
- Connect the LED driver’s terminal block to the disconnected mains supply.
- Connect the driver and the lamp with the connectors.
- Push both spring brackets upwards and insert the recessed spotlight into the ceiling.
- Observe the recommended minimum distances in the ceiling for cooling the luminaire. Do not cover the luminaire and driver with insulating material.
- After the successful initial operation, the installation is complete.
Lens Change
If there is a need to change the lens, please refer to the specific
instructions provided in the manual for proper guidance on how to safely
perform this task.
FAQ
-
Q: Can I replace the light source of the luminaire myself?
A: No, the light source of this luminaire is non-user-replaceable and should only be replaced by Sigor Licht GmbH, an authorized service technician, or a similarly qualified person. -
Q: How should I dispose of the luminaire at the end of its life?
A: Sigor luminaires are RoHS compliant and should be returned to their dealer or an electronic waste collection point for proper disposal. Do not dispose of them in household waste. -
Q: What should I do in case of warranty claims?
A: In case of warranty claims, please contact Sigor Licht GmbH at the provided contact details for further assistance.
Before starting work
Please read and follow this installation and operating manual carefully. The installation of this luminaire must be carried out by an electrician for your safety. Follow safety and health regulations for all activities, especially the relevant selection of VDE 0100. Before starting the installation, isolate the relevant part of the system following the five safety rules. Check the luminaire for integrity before commissioning, only operate undamaged products!
Intended Use
- The Nivo® Recessed Spotlights guarantee protection class IP20 and are intended for installation on solid and stable indoor surfaces using the enclosed constant current driver 350 mA/DC 34 V. Intended use also includes compliance with all information in this manual, especially the safety instructions. Note:
- The luminaires are not intended to be covered with insulating material such as mineral wool. Any other use
is considered improper and may cause property or personal damage.
Non-user-replaceable light source
The light source of this luminaire may only be replaced by Sigor Licht GmbH or
an authorized service technician or a similarly qualified person. (EN 60598-1
3.3.21)
Caution! Risk of electric shock.
Disposal
Sigor luminaires are RoHS compliant and should be returned to their dealer or
an electronic waste collection point at the end of their life. Do not dispose
of them in household waste.
Scope of delivery
- Nivo® Recessed Spotlight swiveling 111 with 5 years Sigor functional guarantee
- HEP Driver G5LT15W350LR-Z
- This installation and operating manual
- Cotton gloves
Disclaimer
Note : In case of non-compliance with this manual and improper use, there
is no warranty claim; Sigor Licht GmbH assumes no liability in such cases.
Installation
-
[1] Switch off the corresponding circuit, and disconnect the power supply indoors.
Create a ceiling cutout with a diameter of 102 mm. -
[2] Connect the LED driver‘s terminal block to the disconnected mains supply.
-
[3] Connect the driver and the lamp with the connectors.
-
[4] Push both spring brackets upwards and insert the recessed spotlight into the ceiling.
-
[5] Please observe the recommended minimum distances in the ceiling for cooling the luminaire. Do not cover the luminaire and driver with insulating material.
-
[6] After the successful initial operation, the installation is complete.
-
[7] For installation with plaster-in rings, please follow step 1 according to a separate guide.
Lens Replacement -
[8] The lens insert (a) is held in the luminaire by three magnets; with a slight rotation of the lens insert in the luminaire (b), the magnets separate, and the lens insert (b) falls out.
Warning
The luminaire head can become hot up to 60°C during operation. Please wait a
moment after switching off or use the included gloves to work on the luminaire
immediately.
Disposal Instructions according to ElektroG
- Owners of old devices must dispose of them separately from unsorted municipal waste. Old devices must not be disposed of with household waste but through special collection and return systems.
- Owners of old devices must separate batteries and accumulators not enclosed by the old device, as well as lamps that can be removed from the old device without destruction, before handing it over to a collection point.
- This does not apply if old devices are handed over to public-law waste disposal authorities and are separated there to prepare them for reuse. Owners of old devices from private households can hand them in free of charge at the collection points of public-law waste disposal authorities or at the collection points set up by manufacturers and distributors by the ElektroG.
- An online directory of collection and return points can be found here: https://www.e-schrott-entsorgen.org/
Some old devices contain sensitive personal data, especially devices in information and communication technology such as computers and smartphones. It is in your interest to ensure that you are responsible for deleting the data on the old devices to be disposed of. The symbol of a crossed-out dustbin on electrical and electronic equipment means that the device must be disposed of separately from unsorted municipal waste at the end of its service life.“
Warranty Conditions
-
The warranty is exclusively for consumers. Warranty protection applies only to products purchased within the Federal Republic of Germany. The warranty period begins on the invoice date.
-
If material or manufacturing defects in the goods you purchased arise during this period and affect the function of the product, we will provide you with a new, defect-free product as part of this warranty. This does not apply in the case of a battery performance fault.
-
In the event of a warranty claim, please contact us as the warranty provider:
Sigor Licht GmbH Phone: +49 2339 1261 0 Eichenhofer Weg 81 Email: reklamation@sigor.de 42279 Wuppertal -
Warranty claims are excluded for damage to the goods due to normal wear and tear and improper or non-intended use or treatment.
-
A prerequisite for claiming warranty service is that you enable us to examine the warranty case (e.g., by sending the goods).
-
If you send the goods for this purpose, please ensure that damage to the goods during transport is avoided through appropriate packaging. A copy of the invoice must be included with the goods shipment for the warranty claim to be reviewed, so we can verify whether the warranty period has been adhered to. Alternatively, you can send a copy of the invoice to us by email. We reserve the right to reject the warranty service if it cannot be determined whether the warranty period has expired.
-
There are no shipping costs for justified warranty claims. In this case, we will refund any shipping costs for the return of the defective goods and bear the costs of shipping a new, defect-free product to you.
Important Note : This warranty does not limit your statutory rights. Instead, the warranty promise is separate from the statutory warranty rights to which you are entitled free of charge.
Sigor Licht GmbH Eichenhofer Weg 81 42279 Wuppertal Germany
Tel. +49 2339 1261-0
Fax +49 2339 1261-61
www.sigor.de
info@sigor.de