S21 Hyd.
Product Manual
Mar. 2024
Specification
Product Glance | Value |
---|---|
Model | S21 Hyd. |
Version | m0-10 |
Crypto algorithm/coins | SHA2561BTC/BCH/BSV |
Typical Hashrate, TH/s(1-1) | 335 |
Power on wall @35°C(1-2), watt 1-1) | 5360 |
Power efficiency on wall@35°C(1-2), j/TH(1-1) | 16.0 |
Detailed Characteristics | Value |
--- | --- |
Power supply
Power supply AC input voltage, Volt(2-1)| 380-415V AC
Power supply AC input frequency range, Hz| 50-60
Power supply AC input current, Amp(2-2)| 12
Hardware configuration
Network connection mode| RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm| 339163207
Server size (LengthWidthHeight, with package), mm| 570316430
Net weight, kg| 12.3
Gross weight, kg| 13.6
Environment requirements
Inlet water temperature, °C(2-3)| 20∼50
Water flow, L/min| 8.0∼10.0
Water pressure bar| ≤ 3.5
Working fluid(2-4)| Antifreeze/Deionized water/Pure water
Liquid PH| 8.5∼9.5
Diameter of water pipe connector, mm| DN10
Storage temperature, °C| -20∼70
Operation humidity(non-condensing), RH| 10∼90%
Notes:
(1-1) The hashrate value, Power on wall, and Power efficiency on wall are all
typical values.
The actual hashrate value fluctuates by ±3%, and the actual Power on wall and
Power efficiency on wall fluctuate by ±5%.
(1-2) Inlet water temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) Three-phase AC input, 12A max.
(2-3) If the inlet water temperature is lower than 20 °C, the miner cannot be
started. For the external dry cooler (EC2-DT),
- if the outlet water temperature is 35°C, the maximum ambient temperature is 30°C;
- if the outlet water temperature is 45°C, the maximum ambient temperature is 40°C;
- if the outlet water temperature is 50°C, the maximum ambient temperature is 45°C.
(2-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.
Performance Curve
(1) Hashrate vs. Inlet Water Temperature
(2) Power Efficiency vs. Inlet Water Temperature