SLV 1004680 Outdoor Floor Stand Luminaire Instruction Manual
- June 1, 2024
- SLV
Table of Contents
SLV 1004680 Outdoor Floor Stand Luminaire
Specifications:
- Model Numbers: 1004680, 1004681
- Power Supply: 220V-240V ~56/60Hz
- Power Consumption: 9.2W
- Light Output: 3000K – 580 lm, 4000K – 630 lm
- Color Rendering Index (CRI): >80
- Weight: 3.00 kg (1004680), 3.50 kg (1004681)
- Cable Type: H05RN-F
Product Usage Instructions
Installation:
Warning: The installation should be performed by an approved electrician following local and national regulations.
- Switch off mains/fixed connection cable before installation.
- Use only described accessories and suitable fastening materials.
- Ground surface mounting is recommended.
- Follow local regulations for outdoor installations.
- Do not seal the product yourself with silicone.
Care and Storage:
- Disconnect the product from the mains and let it cool down before cleaning.
- Clean external surfaces regularly with a slightly moistened cloth; do not use a pressure washer.
- Avoid covering the base with foliage, soil, etc.
- Ensure openings for aeration or drainage remain clear.
- Avoid exposure to acidic surroundings, high salt content, cleaning agents, chemicals, etc.
- Store the product in a dry and clean environment.
Electrical Connection:
- Protect the connection using an IP68 connection box or cable connector (eg, SLV 228730).
- Use a suitable terminal block for connection (400V, 16A).
- Verify secure fixation and proper function after connection.
FAQ:
Q: Can I replace the light source myself?
A: The light source of this luminaire should only be replaced by the
manufacturer, an authorized service technician, or a qualified person.
Q: How should I clean the product?
A: Clean external surfaces with a slightly moistened cloth; avoid using a
pressure washer. Do not cover the base and ensure proper aeration for
longevity.
Q: What type of electrical connection is recommended?
A: Use an IP68 connection box or cable connector for electrical
connections. Ensure proper fixation and function post-connection.
SPECIFICATION
INSTRUCTION MANUAL PART A
Floor lamp
The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.
Technical Details are subject to change.
Operating Manual PART B
Outdoor Floor Stand Luminaire 1004680 …81
Read manual carefully and keep for further use!
- Safety advices for installation and operation.
- Disregard may lead to danger of life, burning or fire!
- Any works on the electrical connection only by electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Operate only with intact protection glass.
- The supply cord may not be covered with soil.
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or a qualified electrician to avoid hazard.
- Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
- Take measures that children get not harmed by the product.
- Do not stare into the active light source.
Additional safety advices =
Use as directed
Safety class I (1) – Connection with protective conductor.
- Do not operate indoors.
- Operate only firmly fixed on an even surface.
- Operate only on normal or not inflammable surfaces.
- Do not strain mechanically or expose to strong dirt contamination.
IP65: Protection against dust (dust-tight) – Protection against jetted
water from all directions.
Admissible ambient temperature(ta): -20°C …+45°C.
Light Source
The light source of this luminaire may only be replaced by the manufacturer,
an authorized service technician or a comparable qualified person.
This product contains a light source of the energy efficiency class D.
Reference control setting: 4000K
Care / Storage
Disconnect product from mains and let it cool down.
Clean external surfaces regularly with a slightly moistened (water) cloth.
Do not clean with pressure washer.
The base may not be covered (e.g. with foliage, soil, etc.)
Openings providing aeration or drainage must be kept free.
The following influences may have unwanted effects on the product: acidic
surrounding, high salt content in the air, cleaningagents, fertilizer, thawing
salt, chemicals.
Store dry and clean.
Installation
- Switch off mains / fixed connection cable!
- Use only described accessories.
- Use only suitable fastening materials.
- Only suited for ground surface mounting.
- Follow local regulations for outdoor installations.
- Do not seal the product yourself (e.g. with silicone).
- Install according to declared IP type.
- Install as shown in the figure.
Types of fixation
Fixation with screws (not included in delivery).
Ground spike (SLV 228722): Fixation in soil.
Concrete anchor (SLV 228712): to be casted into concrete.
Electrical connection
Protect the connection applying an IP 68 connection box or cable connector
(e.g. SLV 228730).
Suitable terminal block: 400V, 16A, Pole: 3
Live conductor Conductor L
Neutral conductor Conductor N
Protective conductor Conductor (PE)
Check secure fixation and proper function!