Combisteel 7464.0315 Series Grab and Go Beverage Cooler User Manual
- June 9, 2024
- CombiSteel
Table of Contents
- Combisteel 7464.0315 Series Grab and Go Beverage Cooler
- Overall appearance of the coolers
- Introduction
- Technical specifications of coolers
- Installation of coolers
- Cleaning, maintenance and transportation of coolers
- Troubleshooting
- Conformity standards of products
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Combisteel 7464.0315 Series Grab and Go Beverage Cooler
Overall appearance of the coolers
- a. Upper cover
- b. Shelf
- c. Front shutter
- d. Legs/castors
- e. Honeycomb
- f. Electronic display
- g. Aluminium profiles
- h. Night cover
- i. Air absorbance vent
NOTE: The information given above and the pictures given on the next pages are optional. They may vary due to models and version.
Introduction
Please read carefully the manual prior to using your cooler in order to have
maximum efficiency from the cooler produced to serve you for long years.
“Environment friendly” technologies have been used, and materials and gases
not harming natural life have been preferred throughout all processes in the
production on of the cooler. Please read this manual carefully and thoroughly
in order to get maximum efficiency and to avoid any usage mistakes. Please
check if the cooler is defective or not upon delivery. In case of any defects,
refer to your authorized dealer within at most 24 hours.
Caution! Wait for at least 2 hours to operate the cooler after any
transportation. If the cooler has been subject to a temperature below 0°C for
a long time, wait for the compressor temperature to reach above +5°C before
starting the cooler again.
Technical specifications of coolers
TECHNICAL FEATURES| Operating temperature (°C)| Exterior
dimensions WxDxH (mm)| Interior dimensions WxDxH (mm)| Max. shelf
load (kg)
---|---|---|---|---
7464.0300| 0 /+10| 655x570x1132| 566x486x529| 29,3
7464.0305| 0 /+10| 655x575x1498| 601x495x907| 29,3
7464.0310| 0 /+10| 655x424x986| 599x286x428| –
7464.0315| 0 /+10| 630×630x1575| 520x300x831| 19,6
7464.0325| 0 /+10| 730×742x1850| 620x402x1103| 25,2
Values specified in above table are given according to standard values and can vary by optional features. Type label is located in the refrigerant part of the cabinet. Please see the back page of the guide for the type label sample.
- Excluding 20mm spacer
- Excluding 80mm spacer
- Excluding 100mm spacer
Climate Classes
Class| Temperature °C| Relative humidity %| Dew point °C
0| 20| 50| 9,3
1| 16| 80| 12,6
2| 22| 65| 15,2
3| 25| 60| 16,7
4| 30| 55| 20,0
5| 27| 70| 21,1
6| 40| 40| 23,9
7| 35| 75| 30,0
8| 23,9| 55| 14,3
Installation of coolers
Air circulation on the back side is necessary to get maximum efficiency from coolers. Push backwards and place the cooler. At least 10cm of space should be left on the side and back part of the cooler. Then connect the plug to the socket.
Usage of coolers
These coolers have been designed to prevent any contact with air from outside thanks to an air curtain. The products to be cooled should be placed on the base section and shelves. The products placed on the base should not hinder absorbance vent. Cooler should not be placed near those areas with high air circulation (such as in front of an air conditioner, under air channel, etc.). Food stuff to be cooled should be placed in a manner not to hinder air circulation. Otherwise there might be great temperature differences between lower and upper sections of the cooler. A heater is placed inside vaporization container on the lower section of the cooler. When the water level reaches to contact such heater, a sizzling sound is produced. Such sound is due to the heating of water but not due to a failure.
For 7464.0300, 7464.0305 and 7464.0310:
Place the products to be cooled onto the shelves. Avoid blocking the suction
vent by the products placed onto the shelves. Don’t place the refrigerator
close to the points having more air circulation (such as in front of an air
conditioner, under air channel, etc.). Food stuff to be cooled should be
placed in a manner not to hinder air circulation. Otherwise there might be
great temperature differences between lower and upper sections of the cooler.
There is no power on/off button on the cooler. Light illuminates at all times.
The replacement of fluorescent tube can be made by opening the white panel. It
is recommended to replace the fluorescent lamp and starter at the same time.
There is no defrosting timing for this product.
Night cover (7464.0315,
7464.0320)
This section is fixed onto the front upper section of the cooler. The cover
should be drawn to save energy during those times when any product is not to
be taken from the cooler other than working times. Open the cover by pulling
the handle and attaching to the cover holder on the front section of the
cooler. When you want the cover closed again, spring mechanism will
automatically be activated upon removing from the holder and rewind the cover.
Air curtain (honeycomb & vent sheet)
This is an air current generated on the front section of the cooler to prevent
cold air within the cooler getting affected by outside air. Air blown from
inside the honeycomb behind the nigh cover on the upper section of the cooler
is absorbed by the absorbance vents on the lower section of the cooler to
produce a current. Honeycomb and vent sheet should not be hindered to prevent
air current from getting affected and low performance of the cooler.
Attaching the shelves
First fit the upmost shelf into the spaces on shelf carrying profiles on the
back corners of the cooler with upper claws into the space, and then after
installing the 2nd claw, press slowly on the shelf to make it properly fit
into the space. Then with the same method attach the other shelves. The
materials inside the cooler are cooled by air circulation so do not place the
shelves close to each other.
Defrosting
Cooling process performs automatic defrosting thanks to thermostat control for
models 7464.0315 and 7464.0320. Water produced after defrosting accumulates in
a channel under water evaporator and conducted to drain pan through a pipe and
evaporated. The models 7464.0300, 7464.0305 and 7464.0310 require manual
defrosting. Defrosting might be accelerated by placing a cup of hot water (not
boiled) under the cooler. Clean the device after defrosting and wipe water and
humidity inside. Plug in the device again and refill the cooler after one
hour. Replacing the fluorescent lighting: (if your product has fluorescent
lamp) Before dismantling the lamp, always unplug your cooler. After
dismantling the lamp cover inside the cooler, remove the lamp and always
replace it with a lamp of the same features (length, power, etc.)
WARNING:
Your cooler can have a fluorescent lamp. If the fluorescent lamp doesn’t illuminate or start blinking, please call technical service to repair it in a short while. Please do not remain your cooler whit non-working lighting system.
WARNING:
Your cooler can have a LED illumination. If you face any problem with LED
illumination, never try to repair it yourself. Inform an authorized service.
For electronic controlled models
Control unit flashes for a few seconds in order to check if all connections
are made correctly when the cooler is plugged in. This is normal, then the
display will indicate current temperature. Set temperature is adjusted to keep
your beverages at optimum temperature, please do not attempt to change the
settings. Control unit set values are protected with a password. Front panel
of control unit is waterproof (IP65). However do not wash the surface where
control unit is placed for safety reasons.
Cleaning, maintenance and transportation of coolers
Clean your cooler regularly for best efficiency. Do not use alcohol (spirit)
cleaning powder or hard materials for cleaning. Plug off your cooler prior to
cleaning. Wipe with a blend including 2 teaspoons of soda water into 1 liter
water. Wipe the external part of your cooler with a wet cloth and dry with a
dry cloth.
Warning: do not use hot water, electrical heater, sharp devices and
similar objects as your cooler might be damaged.
Vacations/intermitting use
If you are to go on a short vacation or stop using the cooler for a while, do
not plug off your cooler. If you are to go on a long vacation or stop using
the cooler for a longer time, plug off and discharge your cooler. Clean and
dry the interior parts of your cooler with a cloth after defrosting.
Transportation
Before relocating the cooler, unplug it from the mains socket, defrost it,
wipe the interior walls and base with a humid cloth and carry it in the normal
position as it is used.
Warning: expansion gas (C-Pentane) is used in the insulation system of the
cooler. When you dispose the body, it requires observing the applicable laws
and rules of the country in which it is used. Cleaning / maintaining of your
cooler’s condenser must be done at least two times in a year by authorized
service.
Troubleshooting
If the cooler does not function:
- Check if the cooler is properly plugged in the mains socket.
- Check if there is electric current to the mains socket.
- Check if the fuse has blown out or if there is power failure.
If the cooler does not cool enough:
- Check if the internal air circulation is interrupted by overloading.
- Cleaning/maintaining of condenser might not be done.
If there is odour in the cooler:
- Check if odorous stuff is openly stored.
- Check if inside is properly cleaned.
After having checked the above mentioned points and carried out the recommendations, if your cooler still functions unsatisfactorily, contact the nearest authorized service centre, informing your complaints as well as the model and serial number of your cooler.
Conformity standards of products
Coolers described in this manual are manufactured and tested in compliance with the
- TS EN ISO 23953-1
- TS EN ISO 23953-2
- TS EN 60335-2-89
- IEC 60335-2-89
- 2006/95/EC,
- 2004/108/EC
References
Read User Manual Online (PDF format)