BEGA 85124K3 Performance Floodlight User Manual
- June 1, 2024
- BEGA
Table of Contents
BEGA 85124K3 Performance Floodlight User Manual
Performance floodlight
Instructions for use
Application
Performance floodlight with mounting box. For a variety of interior and
exterior lighting applications. Product description Luminaire made of
aluminium alloy, aluminium and stainless steel BEGA Unidure® coating
technology Colour graphite or silver Clear safety glass Silicone gasket
Reflector surface made of pure aluminium BEGA Hybrid Optics® Rotation range of
floodlight 350° Swivel range -30°/+80° Mounting box with 2 fixing holes ø
4.8mm · 35mm spacing 1 cable entry for mains supply cable up to ø 10,5mm
Connecting terminals 2.5@ Earth conductor connection BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR
63158, DIN IEC/TR 61547-1 LED power supply unit 220-240 V x 0/50-60 Hz DC
176-280 V BEGA Thermal Control® Temporary thermal regulation to protect
temperature-sensitive components without switching off the luminaire Safety
class I Protection class IP 65 Dust-tight and protection against water jets
Impact strength IK07 Protection against mechanical impacts < 2 joule
Conformity mark Wind catching area: 0.01 m²
Weight: 0.85 kg
This product contains light sources of energy efficiency class(es) E
Lighting technology
Focused light distribution with minimal diffuse light percentage. Half beam
angle 9°
For special lighting applications, an optical filter can be used to change the
symmetrical light cone into a flat beam light distribution.
Lamp
** Module connected wattage| 8.8 W
---|---
Luminaire connected wattage| 10 W
Rated temperature| ta=25 °C
Ambient temperature| ta max=50 °C
85 124K3
Module designation| LED-1268/930
Colour temperature| 3000 K
Colour rendering index| CRI >90
Module luminous flux| 1080 lm
Luminaire luminous flux| 528 lm
Luminaire luminous efficiency| 52,8 lm/W
85 124K4**
Module designation| LED-1268/940
Colour temperature| 4000 K
Colour rendering index| CRI >90
Module luminous flux| 1140 lm
Luminaire luminous flux| 557 lm
Luminaire luminous efficiency| 55,7 lm/W
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components. You can find them on our website
at www.bega.com.
The ideal protection of all electronic components installed in the luminaires
is achieved by using bounce-free switching contacts such as an electronic
relay (solid-state relay), e.g. BEGA 71320.
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Undo hexagon socket head screw (wrench size 3mm) up to the stop and
disassemble the mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Be sure to use the gasket rings supplied. Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection. Connect
the floodlight unit’s green and yellow protective earth conductor to the
terminal marked 1 in the mounting plate. Make sure that gasket is positioned
correctly.
Place floodlight unit onto the mounting plate as displayed in the sketch,
align and screw together firmly.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 3 mm) and set the desired
beam direction.
Tighten the joint screw.
Torque = 2.5Nm.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable between mounting box and floodlight has to be inspected
regarding obvious damages and has to be replaced by a qualified electrician
only.
Please note:
Do not remove the desiccant bag from the luminaire housing. It is needed to
remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module. The light colour and
light output of BEGA replacement modules correspond to those of the modules
originally fitted. The replacement can be carried out by a qualified person
using standard tools. Disconnect the system from the power supply. Open the
floodlight: Remove the trim ring along with the safety glass and reflector by
twisting it anti-clockwise. Replace LED module. Please follow the installation
instructions for the LED module. Inspect and, if necessary, replace the
luminaire gaskets. Defective glass must be replaced. Place the trim ring with
glass and reflector on the floodlight housing so that the notches in the trim
ring and luminaire housing sit on top of each other. Twist on the trim ring
clockwise as far as the stop
Accessories
71 288 Optical filter flat beam
71330 Shield
71 335 Cylindrical shield
For the accessories a separate instructions for use can be provided upon request.
Documents / Resources
| BEGA
85124K3 Performance
Floodlight
[pdf] User Manual
85124K3 Performance Floodlight, 85124K3, Performance Floodlight, Floodlight
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>