MEAN WELL NTS-450 Series 450W High Reliable True Sine Wave DC to AC Power Inverter Owner’s Manual
- June 1, 2024
- MEAN WELL
Table of Contents
- MEAN WELL NTS-450 Series 450W High Reliable True Sine Wave DC to AC Power
- Product Information
- Product Usage Instructions
- Features
- Applications
- Description
- SPECIFICATION
- DERATING CURVE
- Remote ON-OFF Control
- LED STATUS
- Accessory List
- TYPICAL APPLICATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL NTS-450 Series 450W High Reliable True Sine Wave DC to AC Power
Inverter
Product Information
Specifications
- Model: NTS-450 series
- Input Power: 450W
- Waveform: True Sine Wave
- Compliance: IEC62368-1, BS EN/EN62368-1, AS/NZS 62368.1
- Output: AC
Product Usage Instructions
Installation
- Ensure the DC input side is securely connected to a compatible power source.
- Place the inverter in a well-ventilated area with sufficient airflow.
- Connect the AC output side to the device you wish to power.
Operation
- Turn on the DC input side to supply power to the inverter.
- The inverter will convert the DC power to AC power with a true sine wave output.
- Use the AC output to power your mobile devices or other compatible equipment.
Maintenance
Regularly check for any loose connections or signs of wear and tear. Clean the
inverter as needed to prevent dust buildup.
FAQ
-
Q: What should I do if the inverter is not powering my devices?
A: Check the connections and ensure the input power source is functioning correctly. If issues persist, consult the user manual for troubleshooting tips or contact customer support. -
Q: Can this inverter be used in a vehicle?
A: Yes, this inverter’s compact size and light weight make it suitable for use in vehicles to power mobile devices and other electronics.
Features
- Compact size and lightweight
- True sine wave output (THD<3%)
- High surge power up to 900W
- Temperature-controlled cooling fan
- AC output voltage and frequency selectable by DIP S. W
- No load disspation <1.5W max. at standby saving mode
- -25°C~+70°C wide operating temperature
- Power ON-OFF remote control
- Front panel indicator for operation status
- Protections:
- Input: Reverse polarity / DC low alarm / DC low shutdown / Over voltage
- Output: Short circuit / Overload / Over temp.
- Battery over-discharge protection(Low voltage disconnect)
- Suitable for lead-acid or li-ion batteries
- Carry handle accessory available(Order NO.: Carry handle, sold separately)
- Conformal coating
- 3 years warranty
Applications
- Mobile device
- Home and office appliance
- Power tools
- Portable equipment
- Vehicle
- Yacht
- Off-grid solar power system
- Wireless network
- Telecom or datacom system
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
NTS-450 is a 450W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high-quality fan with low acoustic noise, 900W peak power, adjustable AC output voltage and frequency, -25~+70 C wide operating temperature range, complete protections features, etc. combined with batteries, the NTS-450 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, etc.
Model Encoding
SPECIFICATION
MODEL NO.| NTS-450-112| NTS-450-124| NTS-450-148|
NTS-450-212| NTS-450-224| NTS-450-248
---|---|---|---|---|---|---
= US, GFCI, UN| = EU, CN, AU, UK, UN
AC OUTPUT| RATED POWER(Continuous)| 450W
OVER RATED POWER(3 Min.)| 517.5W
PEAK POWER(10 Sec.)| 675W
SURGE POWER(30 Cycles)| 900W
AC VOLTAGE| Default setting set at 110VAC| Default setting set at 230VAC
100 / 110 / 115 / 120Vac selectable by DIP S.W| 200 / 220 / 230 / 240Vac
selectable by DIP S.W
FREQUENCY| Default setting set at 60Hz±0.1Hz| Default setting set at
50Hz±0.1Hz
50/60Hz selectable by DIP S.W| 50/60Hz selectable by DIP S.W
WAVEFORM **Note.1| True sine wave (THD<3%)
AC REGULATION| ±3.0% at rated output voltage
FRONT PANEL LED| Please refer to page5
DC INPUT| DC VOLTAGE| 12V| 24V| 48V| 12V| 24V| 48V
VOLTAGE RANGE (Typ.)| 10 ~ 16.5Vdc| 20 ~ 33Vdc| 40 ~ 66Vdc| 10 ~
16.5Vdc| 20 ~ 33Vdc| 40 ~ 66Vdc
DC CURRENT (Typ.)| 50A| 25A| 14A| 50A| 25A| 14A
NO LOAD DISSIPATION**
(Typ.)
| NON-SAVING MODE| 10W| 10W| 12W| 10W| 10W| 12W
SAVING MODE
| Default disable, ≦1.2W ~ 1.5W by models @ auto detec AC output load ≦10W
will be changed to saving mode
1.2W| 1.3W| 1.5W| 1.2W| 1.3W| 1.5W
OFF MODE CURRENT DRAW| ≦1mA
EFFICIENCY (Typ.) Note.1| 88%| 91%| 91%| 90%| 93%| 93%
BATTERY TYPES| Lead Acid or li-ion
PROTECTION| DC INPUT| FUSE (Internal)| 40A2| 40A1| 10A2|
40A2| 40A1| 10A2
LOW| ALARM| 11±0.3Vdc| 22±0.5Vdc| 44±1Vdc| 11±0.3Vdc| 22±0.5Vdc|
44±1Vdc
SHUTDOWN| 10±0.3Vdc| 20±0.5Vdc| 40±1Vdc| 10±0.3Vdc| 20±0.5Vdc| 40±1Vdc
RESTART| 12.5±0.3Vdc| 25±0.5Vdc| 50±1Vdc| 12.5±0.3Vdc| 25±0.5Vdc|
50±1Vdc
HIGH| ALARM| 15.5±0.3Vdc| 31±0.5Vdc| 62±1Vdc| 15.5±0.3Vdc|
31±0.5Vdc| 62±1Vdc
SHUTDOWN| 16.5±0.3Vdc| 33±0.5Vdc| 66±1Vdc| 16.5±0.3Vdc| 33±0.5Vdc|
66±1Vdc
RESTART| 15±0.3Vdc| 30±0.5Vdc| 60±1Vdc| 15±0.3Vdc| 30±0.5Vdc| 60±1Vdc
BAT. POLARITY| By internal fuse open
AC OUTPUT| OVER TEMPERATURE| Protection type : Shut down o/p
voltage, re-power on to recover
OUTPUT SHORT| Protection type : Shut down o/p voltage, re-power on to
recover
OVER LOAD (Typ.)| 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10
sec.
Protection type : Shut down o/p voltage, re-power on to recover
GFCI PROCTECTION
| Design refer to UL458
(Only for “GFCI” AC socket , by request)
| ****
None
FUNCTION| REMOTE CONTROL| Power ON-OFF remote control by front
panel dry contact connector (by RELAY); Open : Normal work ; Short , Remote
off
ENVIRONMENT| WORKING TEMP.| -25 ~ +70℃(Refer to “Derating curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-
condensing
VIBRATION| 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC ( Note.4)| SAFETY STANDARDS| CB
IEC62368-1,Dekra BS EN/EN62368-1,E13,EAC TP TC 004 approved;Design refer to
AS/NZS 62368.1 (Please refer to next page“AC output socket” table for more
details) ; Design refer to UL458 (By request)
WITHSTAND VOLTAGE| DC I/P – AC O/P:3.0KVac AC O/P – FG:1.5KVac
EMC EMISSION| Parameter| Standard| Test Level / Note
Radiated| FCC for 112,124,148 only(expect for Type-UN)| Class A
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)| Class A
Harmonic Current| BS EN/EN61000-3-2| —–
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55024, BS EN/EN55035
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2 , 3V/m
Magnetic Field| BS EN/EN61000-4-8| Level 1 , 1A/m
OTHERS
| MTBF| 843.9K hrs min. Telcordia TR/SR-332 (Bellcore) ; 85K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 21013055mm (LWH)
PACKING| 1.3Kg; 8pcs/ 11.4Kg/ 1.74CUFT
NOTE| 1. Efficiency, AC regulation and THD are tested by 450W, linear
load at 12.5Vdc/25Vdc/50Vdc input voltage.
2. All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
3. Internal pre-start circuit, the setup time is 8s.
4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
AC Output Socket
DERATING CURVE
Remote ON-OFF Control
Remote ON-OFF | AC Output Status |
---|---|
Open | power inverter ON |
Short | power inverter OFF |
AC Output Voltage, Frequency, Power saving mode selectable by DIP SW
Output voltage and frequency setting factory settings are either
110Vac/60Hz or 230Vac/50Hz, users are able to adjust the voltage and
frequency, through the DIP switch of position 1,2,3,4 on the panel.
AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW
SW1| SW2| SW3| SW4
OFF| OFF :| 100Vac or 200Vac| ON: 50Hz| ON: Saving mode
OFF| ON :| 110Vac or 220Vac
ON| OFF :| 115Vac or 230Vac| OFF: 60Hz| OFF: Non-Saving mode
ON| ON :| 120Vac or 240Vac
LED STATUS
Normal work:
Abnormal status:
MECHANICAL SPECIFICATION
Accessory List
※Carry handle (Optional accessory, Power inverter and Pull handle should ordered separately).
TYPICAL APPLICATION
INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html