NINGBO DM25LE/L Tubular Motor User Manual

June 1, 2024
Ningbo

NINGBO DM25LE/L Tubular Motor

Product Information

Specifications

  • Type: DM25LE/L
  • Rated Voltage: 8V/12V
  • Emission Frequency: 433.92MHz
  • Working Temperature: -10°C to +55°C

Product Usage Instructions

Functional Features

  • Electronic Limit Stall Protection
  • Jog & Tilt Program Button
  • Speed Regulation
  • Memorized Setting
  • Built-in Lithium Battery
  • Switch Direction
  • Built-in Receiver
  • Preferred Stop Position
  • Reset to Factory Mode
  • DC Power Solar Charging

Usage Instructions

  1. Charging: Use a DC782 charger or solar panels DC683B to charge the built-in battery. Red light indicates charging, and green light indicates full charge.
  2. Maximum Running Time: The Motor stops automatically after running for 6 minutes without any operation.
  3. Reversing Rotation: Use the P1 button for direction setting.
  4. Limit Position Setting:
  5. Enter limit position setting mode.
  6. Set up and down-limit positions for curtain movement.

FAQ

  • Q: What should I do if the emitter is lost?
  • A: To set up again with a new emitter, follow the instructions provided in the manual.
  • Q: How do I know if the battery is fully charged?
  • A: The charger light shows red during charging and turns green when the battery is fully charged.
  • Q: What happens if I haven’t completed the limit setting?
  • A: If the limit setting is not completed, the motor will exit the setting mode. Complete the limit setting to ensure proper operation.

SAFETY NOTE

  1. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  2. Children shall not play with the appliance.
  3. Cleaning and user maintenance shall not be done by children without supervision.
  4. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard.
  5. WARNING: the drive shall be disconnected from its power source during cleaning, maintenance and replacement parts.
  6. The instructions shall state that the A-weighted emis sion sound pressure level of the drive is equal to or less than 70 dB(A), e.g. by writing LpA ≤ 70 dB(A).
  7. The mass and the dimension of the driven part shall be compatible with the rated torque and rated operating time.
  8. The type of driven part the drive is intended for.
  9. WARNING: Important safety instructions. It is important for the safety of persons to follow these instructions. Save these instructions.
  10. Do not allow children to play with fixed controls. Keep remote controls away from children
  11. Frequently examine the installation for imbalance and signs of wear or damage to cables and springs. Do not use if repair or adjustment is necessary
  12. Watch the moving shutter and keep people away until the shutter is completely closed
  13. WARNING: Important safety instructions. Follow all instructions, since incorrect installation can lead to severe injury.
  14. Before installing the drive, remove any unnecessary cords and disable any equipment not needed for powered operation

Product introduction

One motor maximum can store 20 channels, over 20 channels, if still need to add new channels, it will repeat the covered last channel.

Functional features

  • Electronic Limit
  • Stall Protection
  • Jog & Tilt
  • Program Button
  • Speed Regulation
  • Memorized Setting
  • Built-in Lithium Batt
  • Switch Direction
  • Built-in Receiver
  • Preferred Stop Position
  • Reset to Factor Mode
  • DC Power
  • Solar Charging

Parameter (More models and parameters are subject to the nameplate)

  • Type: DM25LE/L
  • Rated Voltage: 8V/ 12V
  • Emission Frequency: 433.92MHz
  • Working Temperature: -10℃ ~ +55℃

Motor installation

  1. Driving tube must be close-fitting with crown and drive adapter.
  2. Choose a crown and drive adapter based on the driving tube.

NINGBO-DM25LE-L-Tubular-Motor-fig-2 NINGBO-
DM25LE-L-Tubular-Motor-fig-3

Charging instructions

  • The motor has a built-in battery,0.7nm motor uses a DC782 charger to charge.
  • You can also use solar panels DC683B to charge; when the battery is low, insert the charge, charger light shows a red light. batteries are full when the red light turns to green.

NINGBO-DM25LE-L-Tubular-Motor-fig-4

Operation note

Please read the following precautions before use:

  1. Don’t operate motors when low voltage alarm:
    • 8V motor power supply voltage is below 6.8V when the motor stops running when the voltage is more than 7.5V to restart; When the power supply voltage is lower than 7.5V motor, the motor will call the alarm and the buzzer will call 10 times.
    • 12V motor power supply voltage is below 8.0V when the motor stops running when the voltage is more than 8.5V to restart; When the power supply voltage is lower than 7.0V when the motor stops the buzzer call when the voltage is greater than 7.5V before starting again; When the power supply voltage is lower than 10V motor, the motor will call the alarm and the buzzer will call 10 times.
  2. Operating:
    • The valid interval of the emitter button is 10s, the emitter will quit the set after 10s.
    • The motor will run or beep for the hint, please do the next step after the hint.
  3. Set limit position:
    • After the up/down limit position setting, the up/down limit position can’t at the same position.
    • After limit setting, with power off and memory function.
    • Into the match-code status 2 minutes later, it will quit out the setting limits status automatically.
    • It will delete every memory and restore the factory settings.
  4. When the motor runs without any operation, the maximum running time is 6 minutes,it will stop automatically.
  5. If the emitter is lost, please set it up again with the new emitter.

Button specification

NINGBO-DM25LE-L-Tubular-Motor-fig-6

Setting up P2→P2→Up

  • If you need to reverse the rotation of the motor controlled by the emitter, please run the reverse of direction setting(see the motor P1 button operation).

NINGBO-DM25LE-L-Tubular-Motor-fig-7

Note: after the success of the code, remove the original travel setting and the speed of the motor operation mode, and restore the factory value.

Limit position setting

  • Enter the limit position setting mode P2→Up→P2

NINGBO-DM25LE-L-Tubular-Motor-fig-8

Note: This operation must be carried out without the limit; In the process of the motor running upward or downward, press the emitter setting button,the motor enters the jog-move operation state, can precisely set the limit position.

  • Set the up limit position Up→Stop→Stop

NINGBO-DM25LE-L-Tubular-Motor-fig-9

  • Set the down limit position Down→Stop→Stop

NINGBO-DM25LE-L-Tubular-Motor-fig-10

Note: After the motor is powered off again, it will exit the trip setting mode; If you have not completed the limit, you will exit the setting mode of the limit, if you already have a limit, you will continue to use the pre-set limit;If the motor already has a limit, you need to delete the limit before you can set the limit.

Fine-tuning the up/down limit position setting

  • Up+Down→Up/Down→Stop

NINGBO-DM25LE-L-Tubular-Motor-fig-11

Preferred stop position

  • P2→Stop→Stop
  • After the up limit and down limit setting, you can set the preferred stop position between them as the half-open position.

NINGBO-DM25LE-L-Tubular-Motor-fig-12

Note: In continuous moving mode, long press stop button, the curtain runs directly from the current position to the preferred stop position(Apply to the shade); in Jog-move mode, long press stop button, The motor will first run to the down limit position, then run to preferred stop position(Apply to Venetian blinds); Repeat this operation to remove preferred stop position.

Jog-move setting

  • P2→Up→Down

NINGBO-DM25LE-L-Tubular-Motor-fig-13

Note: Repeat this operation to cancel the dot-move function;In the jog- move mode, short press up/down burron 2s to loosen, the motor is jog-move to run;If long press more than 2s, the motor run continuously.

Add emitter

NINGBO-DM25LE-L-Tubular-Motor-fig-14

Note: Emitter (a) is the one that already matches the code, while emitter (b) has not; Repeat method one to remove the added emitter (b) ; After the success of the code to retain the original motor all the settings.

Delete all emitters

  • P2→Stop→P2

NINGBO-DM25LE-L-Tubular-Motor-fig-15

Cancel limit

  • P2→Down→P2

NINGBO-DM25LE-L-Tubular-Motor-fig-16

Note: This operation together with the preferred stop position to delete.

Speed Regulation

  1. Improve the speed of the motor Up+Stop
  2. Reduce the motor running speed Down+Stop

Note: If the motor does not run for hint, indicate that the motor has reached the maximum or minimum value.

Motor P1 button operation

  • Short press operation

NINGBO-DM25LE-L-Tubular-Motor-fig-19

Note: This operation should be carried out under the conditions of motor has the limit.

  • Setting up or add emitter

NINGBO-DM25LE-L-Tubular-Motor-fig-20

  • Shielding wireless function

NINGBO-DM25LE-L-Tubular-Motor-fig-21

Note: the motor enters the wireless shield mode, saves the previous system function setting and the emitter code, and closes the wireless reception function(short press P1 to restore wireless reception).

Switch direction

NINGBO-DM25LE-L-Tubular-Motor-fig-22

Note: After the success of the reversing, motor limit remains the same.

Reset to factor mode

NINGBO-DM25LE-L-Tubular-Motor-fig-23

Fault and solution

NINGBO-DM25LE-L-Tubular-Motor-fig-24

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.RF Exposure Information

The device has been evaluated to meet general RF exposure requirement.
The device can be used in portable exposure condition, compliance with exposure requirements.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Ningbo User Manuals

Related Manuals