SLV 1007502 Panel V DALI 625 LED Recess-Mounted Ceiling Light Instruction Manual

June 1, 2024
SLV

INSTRUC TION MANU AL PART A
Recess-Mount ed Ceilin g Light

1007502/1007503
1007504/1007505

1007502 Panel V DALI 625 LED Recess-Mounted Ceiling Light

SLV 1007502 Panel V DALI 625 LED Recess-Mounted Ceiling Light - Fig
1

 The inst allation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and nationa regulations!

The light source is only exchangeable by a prof essional. The separate control unit is only exchangeable by a professional.

Technical Details are subject to change.

SLV UK
Unit E Chiltern Park
Boscombe Road, Bedfordshire
LU5 4LT

Operating Manual PART B
Recess-Mounted Ceiling Light
1007502 …03 …04 …05

Read manual carefully and keep for further use!

Safety advices for installation and operation.
Disregard may lead to danger of life, burning or fire!
Any works on the electrical connection only by electrician.
Do not alter or modify the product.
Do not fasten anything on the product.
Do not cover the product.
Take out of service when suspecting a defect or matfunction and contact your dealer or a qualified electrician.
Take measures that children get not harmed by the product.
Do not stare into the active light source.
Additional safety advices =

Use as directed

Safety class Il (2) Icon– Safety insulated – Connection without protective conductor.
Operate only firmly fixed on an even surface.
Operate only on normal or not inflammable surfaces.
Operate only indoors.
Do not strain mechanically or expose to strong dirt contamination.
IP40: Protection against foreign objects > Ø 1,0mm – No protection against water.
IP54: Protection against disturbing dust deposition – Protection against splashing water from all directions.
Admissible ambient temperature(ta): -20°C …+40°C.

Light Source

The light source of this luminaire may only be replaced by the Manufacturer, an authorized service technician or a comparable qualified person.
1007502 ..03
This product contains a light source of the energy efficiency class E. 1007504 …05
This product contains a light source of the energy efficiency class F.

Care / Storage
Disconnect product from mains and let it cool down.
Clean external surfaces regularly with a slightly moistened (water) cloth.
Store dry and clean.

Installation

Switch off mains / fixed connection cable!
Use only described accessories.
1007502 …04
Only for installation into grid ceilings 60 x 60 cm.
1007503 …05
Only for installation into grid ceilings 62 x 62 cm.
Keep sufficient distance to inflammable materials.
Ensure sufficient aeration.
: Do not cover, especially not with insulating materials.
Install as shown in the figure.

Electrical connection

Equip flexible wire ends with suitable wire ferrules!
Direct the fixed installation cable through strain relief.
Live conductor →Terminal L
Neutral conductor → Terminal N
Dali control wires → Terminals DA
Secure strain relief.
Ensure that the fixed installation cable is securely kept by the strain relief.
Check secure fixation and proper function!

0001 06.06.2023 © SLV GmbH , Daimlerstr .
21 -23, 52531 Übach-Pale nberg, Germany,
Tel. + 49 (0)2451 4833-0.
Made in China.