SLV 1007502 Recess Mounted Ceiling Light Instruction Manual
- June 1, 2024
- SLV
Table of Contents
SLV 1007502 Recess Mounted Ceiling Light
Product Information
- Specifications
- Model Numbers: 1007502, 1007503, 1007504, 1007505
- IP Rating: IP40, IP54
- Voltage: 220V-240V ~50/60Hz
- Luminous Flux: 4100 lm (3000K), 4300 lm (4000K), 4000 lm (3000K)
- Power Consumption: 34W
- Color Rendering Index (CRI): >80
- Dimensions: 59.5 x 59.5 x 2.8 cm, 62 x 62 x 2.8 cm
- Weight: 1.70 kg, 1.80 kg, 1.90 kg, 1.95 kg
Product Usage Instructions
- Installation
- Warning: The installation must be carried out by an approved electrician following local and national regulations.
- Disconnect the product from the mains before installation.
- Mount the product as shown in the installation diagram.
- Ensure the electrical connections are made securely and follow the specified wiring instructions.
- Keep a safe distance from flammable materials and ensure proper ventilation around the product.
- Maintenance and Care
- Warning: Do not cover the product or modify it in any way.
- Regularly clean the external surfaces with a slightly moistened cloth.
- Store the product in a dry and clean environment when not in use.
- Light Source Replacement
- Warning: The light source should only be replaced by a qualified person.
- Disconnect the product from the mains before replacing the light source.
- Replace the light source with the same type recommended by the manufacturer.
FAQs
- Q: Can I install the product myself?
- A: No, the installation must be done by an approved electrician.
- Q: How do I clean the product?
- A: Use a slightly moistened cloth to clean the external surfaces regularly.
FEATURE
INSTRUCTIONS PART
- INSTRUCTION MANUAL PART A Recess-Mounted Ceiling Light
- 1007502
- 1007503
- 1007504
- 1007505
The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.
Technical Details are subject to change.
Operating Manual
Operating Manual PART B Recess-Mounted Ceiling Light 1007502 …03 …04 …05
- Read the manual carefully and keep it for further use!
- Safety advice for installation and operation.
- Disregarding may lead to danger of life, burning or fire!
- Any work on the electrical connection only by the electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
- Take measures that children are not harmed by the product.
- Do not stare into the active light source.
- Additional safety bits of advice =
Use as Directed
- Safety class II (2) – Safety insulated – Connection without a protective conductor.
- Operate only firmly fixed on an even surface.
- Operate only on normal or not inflammable surfaces.
- Operate only indoors.
- Do not strain mechanically or expose to strong dirt contamination.
- IP40: Protection against foreign objects > Ø 1,0mm
- No protection against water.
- IP54: Protection against disturbing dust deposition
- Protection against splashing water from all directions.
- Admissible ambient temperature(ta): -20°C …+40°C.
Light Source
- The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician or a comparable qualified person.
- 1007502 …03
- This product contains a light source of the energy efficiency class E.
- 1007504 …05
- This product contains a light source of the energy efficiency class F.
Care / Storage
- Disconnect the product from the mains and let it cool down.
- Clean external surfaces regularly with a slightly moistened (water) cloth. Store dry and clean.
Installation
- Switch off mains / fixed connection cable!
- Use only described accessories.
- 1007502 …04
- Only for installation into grid ceilings 60 x 60 cm.
- 1007503 …05
- Only for installation into grid ceilings 62 x 62 cm.
- Keep sufficient distance from inflammable materials.
- Ensure sufficient aeration.
- Do not cover, especially not with insulating materials. Install as shown in the figure.
Electrical connection
- Equip flexible wire ends with suitable wire ferrules!
- Direct the fixed installation cable through strain relief.
- Live conductor Terminal L
- Neutral conductor Terminal N
- Dali control wires Terminals DA
- Secure strain relief.
- Ensure that the fixed installation cable is securely kept by the strain relief.
- Check secure fixation and proper function!