Specifications:
- Model: Item#1459-XXX
- Date: New.11/30/2023
- Maximum Bulb Wattage: 60 watts each
- Support Cable Length: Adjustable
- Fixture Body Material: Metal
Product Usage Instructions
Preparation:
- Shut off power at the fuse box or circuit breaker box and remove the old fixture.
- Unpack the new fixture and lay out all parts in a clean area.
Assembling the Fixture with Chain Loop:
- Secure tube (J) into all thread (I) of fixture body, passing wires carefully through the metal tube.
- Determine the desired hanging height and attach loop (H1) by threading it to the rod (F1).
- Attach quick link (G) to connect loop (H1) and loop (H2) on the canopy (D).
Connecting the Wires:
- Connect the electrical wires as shown in Fig 2, ensuring all wire connectors are secured.
- If there is a ground wire present, connect the fixture’s ground wire to it; otherwise, connect it directly to the circular strap using the provided green screw.
Completing the Installation:
- Secure canopy (D) with screws (A) and knobs (E).
- Place candle covers (M) over sockets (N) of fixture body.
- Install five candelabra base bulbs (L) up to 60 watts each or equivalent CFL/LED bulbs.
FAQ:
Q: What should I do if I exceed the maximum bulb wattage rating?
A: It is important not to exceed the maximum wattage rating specified for
the fixture to prevent damage or hazards. Ensure to use bulbs within the
recommended wattage range.
Q: Can I adjust the length of the support cable?
A: Yes, the support cable provided can be adjusted to suit the hanging
height of the fixture. Follow the instructions provided to adjust it
accordingly.
INSTALLATION INSTRUCTIONS
Item#1459-XXX (New.11/30/2023)
READ AND SAVE THESE INSTRUCTIONS
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
PREPARATION (Fig. 1)
-
Shut off power at the fuse box or circuit breaker box and remove the old fixture including mounting hardware.
-
Carefully unpack your new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.
ASSEMBLING THE FIXTURE WITH CHAIN LOOP (Fig.1) -
Secure tube (J) into all thread (I) of fixture body, pass wires carefully through metal tube as you assemble.
-
Determine the desired hanging height and thread rods (F1, F2 and F3) to all thread of tube (J). Then attach loop (H1) by threading it to rod (F1).
-
Carefully pass wires through each rod as you assemble.
-
Attach quick link (G) connect to loop (H1) and loop (H2) on canopy (D).
-
Carefully feed wire over loop (H1), quick link (G) and loop (H2).
-
Thread screws (A) into the pre-drilled holes in circular strap (B) spaced same distance apart as holes in canopy (D). The length of screws (A) may be adjusted if necessary.
-
Attach circular strap (B) to junction box (Not included) with mounting screws (C) (Size: #8-32N*L0.5”). The side of circular strap (B) marked “GND” must face out.
-
The support cable is provided to support the weight of fixture while wiring. Align fixture to circular strap (B) and attach hook (P) on the end of support cable (K) into a slot located on circular strap (B). Carefully allow support cable (K) to support weight of fixture while wiring (Fig.1)
CONNECTING THE WIRES (Fig. 2) -
Connect the electrical wires as shown in Fig 2, making sure that all wire connectors are secured. If your outlet has a ground wire (green or bare copper), connect the fixture’s ground wire to it.
Otherwise, connect fixture’s ground wire directly to circular strap using green screw provided. -
Tuck wire connectors neatly into junction box and raise canopy all the way to ceiling.
COMPLETING THE INSTALLATION (Fig. 1) -
Thread screws (A) into canopy (D), and secure with knobs (E).
-
Place candle covers (M) over sockets (N) of fixture body.
-
Install (5) five candelabra base bulbs (L) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification. — DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!)
Your installation is now complete. Return power to the junction box and test the fixture.