ERMENRICH Reel SLR540 Laser Meter User Manual

June 2, 2024
ERMENRICH

ERMENRICH Reel SLR540 Laser Meter

Specifications

Dimensions: 86x50x80mm / 3.4×2.0x3.1in

Weight: 305g / 0.67lb

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Product Usage Instructions

  • Turning the Device On/Off and Taking Measurements
    • Press and hold the Power/measure button (1) for 3 seconds to turn the device on/off. Aim the laser beam at the target and press the Power/measure button (1) to take a measurement.
  • Reference Point
    • The default reference point is the bottom end of the device. To get a measurement value from the top of the device, and subtract 86mm (3 3/8in) from the obtained measurement (the length of the device).
  • Changing Units of Measurement
    • To change the unit of measurement, press and hold the Power/measure button (1) for 3 seconds.
  • Care and Maintenance
    • Battery Safety Instructions: Ensure proper handling of batteries as per manufacturer guidelines.

FAQ

  • *  **Q: How do I change the reference point on the device?**
    • A : The default reference point is the bottom end of the device. To measure from a different reference point, manually adjust your calculations by considering the device’s length.
    • Q: What should I do if the device does not turn on?
    • A : Check the battery compartment and ensure the batteries are properly inserted. If the issue persists, contact customer support for further assistance.

Parts overview

ERMENRICH-Reel-SLR540-Laser-Meter-fig2

  1. Power/measure button
  2. LCD screen
  3. Tape locking button
  4. Strap mount (not shown)
  5. Laser emitter
  6. Laser receiver
  7. Magnet hook

Screen interface

  1. Battery status indicator
  2. Reference point
  3. Mode (distance/area/ volume)
  4. First measurement value
  5. Current value

Ermenrich Reel SLR540 Laser Meter

  • Using
    • Press (1) and hold it for 3 seconds to turn the device on/off. Aim the laser beam at the target and press (1) to take a measurement.
  • Reference point
    • The default reference point is the bottom end of the device. To know a measurement value from the top of the device, subtract 86mm (3 3/8in) (the length of the device).
  • Units of measurement
    • Press (1) and hold it for 3 seconds to change the unit of measurement.

Specifications

  • Measuring range / 0.2–40m
  • Measuring accuracy/ 3mm
  • Units of measurement / m, ft, in
  • Laser class / class II, 630–670nm, < 1mW
  • Battery life / 5,000 measurements
  • Power supply /2 AAA batteries
  • Device auto-off /180 seconds
  • Tape length /5m
  • Operating temperature range, °C/°F / 0… +40 (operating), –10… +60 (storage) / +32…+104 (operating), +14…+140 (storage)
  • Dimensions/ 86x50x80mm / 3.4×2.0x3.1in
  • Weight/ 305g / 0.67lb

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Care and maintenance

Please carefully read the safety instructions and user manual before using this product. Otherwise, it may result in hazardous laser radiation and electric shock. Keep away from children.

This is a class II laser product. Please DO NOT look directly into the beam with unprotected eyes or through an optical device at any time and never direct it toward other people. Do not remove any safety labels. Do not aim the device directly at the sun. Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Do not use the product in an explosive environment or close to flammable materials. Store the device in a dry cool place. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately.

Battery safety instructions

Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones or batteries of different types. Clean the battery contacts and also those of the device priorto battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.

Levenhuk International Lifetime Warranty

All Levenhuk telescopes, microscopes, binoculars, and other optical products, except for their accessories, carry a lifetime warranty against defects in materials and workmanship. A lifetime warranty is a guarantee on the lifetime of the product on the market. All Levenhuk accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions are met.

For further details, please visit: www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.

References