Temtop P10 Air Meter User Manual
- June 5, 2024
- Temtop
Table of Contents
Temtop P10 Air Meter User Manual
Factors Affecting Air Quality
PM2.5 (Particulate Matter 2.5) refers to particulates with diameter of 2.5 micrometers or less. Due to its tiny size, PM2.5 can be absorbed by bloodstream via the lungs. Exposure to high concentrations of PM2.5 may cause eye and nose irritation, cough, asthma, emphysema, lung disease, cancer or other respiratory and cardiovascular diseases.
Formaldehyde is a colorless and strong-smelling chemical with formula CH2O or H-CHO, which has been classified by IARC as Group ‘carcinogen due to its significant dangers to human health. Long-term exposure to just low doses could cause chronic respiratory diseases, nasopharyngeal cancer, colon cancer, brain tumors, nuclear gene mutations and etc.
TVOC (Total Volatile Organic Compounds) refers to various common VOCs including benzene, toluene, styrene, formaldehyde and etc. Due to their volatility as well as toxicity, irritability and carcinogenicity, long-term exposure to TVOCs can cause damage to the skin, liver, kidneys, central nervous system and etc.
AQI (Air Quality Index) is a quick guide on air quality levels. It aims to indicates how clean or polluted the air is in a way that’s easy to understand. It ranges from 0 to 500 that higher values indicate higher air pollution levels and more adverse for health. AQI assessment can indicated for PM2.5, PM10, 03, 502, NO2, CO etc. Temtop follows EPA Standards to calculate and focus only for AQI of PM2.5&10.
Warnings!
-
Do not place the detector in heavily polluted environment for a long time. Otherwise, the sensor may be damaged and cannot run normally.
-
Do not use the detector in humid environment in order to maintain the detection accuracy.
-
Do not cover the air inlet/outlet while in use.
Do not let fluff or hair entering the detector. -
Try to avoid using the product in the environment with strong odour or pungent smell.
Product Overview
Only M10i has this symbol.
Functions
Model /Function
| P10| M10| M10i
---|---|---|---
PM2.5| ✓| ✓|
✓
AQI*
| ✓| ✓| ✓
HCHO| | ✓|
✓
TVOC
| | ✓| ✓
Wi-Fi| | |
✓
- Following the US EPA Standards for Particle Pollution to calculate AQI.
Specifications
Model: P10/M10/M10i | PM2.5 |
---|---|
Battery capacity: 2200mAh | Sensor: Laser PM sensor Measuring range: 0-999mg/m3 |
Resolution: 1µgm3
Accuracy: +10[Jg/m3(0-100mg/m3);
+10%mg/m3(others)
Battery life: Aqpm6 hours on a single charge
Input: DC SV; 0.5A-1A
Operating environment: 0-50°C;0-90%RH
Dimensions: 82x82x31 mm3.2×3.2×1.2 in| HCHO3
Weight: 200g| Sensor : Electrochemical sensor Measuring range: 0-2mg/m3
Resolution: 0.01mg/m3
Accuracy: ±0.03mg/m3 (0.03mg/m3);
±10%mg/m3(others)
TVOC Measuring range’: 0-5mg/m3
TVOC Resolution; 0.01mg/m3
This Function is for M10/M10i only.
Operations
Before you begin
Unpack and take out the detector.
Place it outdoors for more than 6 hours for calibrations.
Turn On/Off
Press and hold Home button for 2 seconds to turn on/off the detector. After
turn on, please wait for the countdowns.
Display
-
M10/M10i Model
HCHO concentration will auto display after the countdowns:
Then press Home Button to display PM2.5 concentration:
Then press Home Button to display TVOC concentration;
Then press Home Button again to display AQI index:
Other Operations
Manual Loop: Repeat above steps can manually loop the display in order of ncno, PlViz.5, +voc, AQi.
Auto Loop: Double press Home Button can auto loop each display every 3s. Double press again to exit Auto Loop mode.
Note: For further Wi-Fi connecting instructions to M10i model, please refers to another manual that ¢omes along: “MJ0i Add Devi¢e and Connect Wi-Fi. -
P10 Model
PM2.5 concentration will auto display after turn on countdowns;
Then press Home Button to display AQI index:
Other Operations
Manual Loop: Repeat above steps can manually loop and display the PM2.5, AQI.
Auto Loop: Double press Home Button can auto loop each display every 3s. Double press again to exit Auto Loop mode.
Indicator Lights
The indicator lights on the panel indicate the corresponding air quality:
Status
| Good| Fair| Poor
---|---|---|---
Color| Green| Yellow|
Red
The battery level indicator on the screen indicates the device charging status:
Status
| Charging| Full
---|---|---
Color| Yellow|
Green
Charging
When battery level is low, please charge by connecting it with the USB cable and power supply.
**HCHO Calibration***
It is suggested to calibrate the detector after 3 months usages. The calibration instructions are showing below:
- a) Turn on the detector and wait for about 10 minutes.
- b) Use the pin tool to press the calibration button for more than 10 seconds until HCHO icon blinks on the screen.
- c) Place the detector outside for 10 minutes for ventilation.
- d) When HCHO icon does not blink, it indicates that the calibration has finished.
Air Quality Parameter for Reference
Status/ Pollutant | Good | Fair | Poor |
---|---|---|---|
PM2.5 (µg/m3) | ≤12 | 12.1∼55.4 | ≥ 55.5 |
AQI* | ?50 | 51-150 | ≥ 151 |
following the EPA Standards for Particle Pollution to calculate AQI for PM2.5.
Status/ Pollutant
| Healthy| Unhealthy
---|---|---
TVOC (mg/m3)
| ≤ 0.5|
0.5
HCHO| ≤ 0.1|
0.1
What’s Included
-
Air Quality Detector x1
-
P10/M10/M10i Manual x1
-
USB Cable x1
-
Pin Tool* x1
-
MlOi Add Device and Connect Wi-Fi Manual** x 1
-
Only included for M10 and M101
** Only included for MlOi
Elitech Technology, Inc.
2528 Qume Dr, Ste 2
San Jose, CA 95131 USA
Tel: +1 408-898-2866
Sales: sales@temtopus.com
Website: www.temtopus.com
Elitech (UK) Limited
Unit 13 Greenwich Business Park,
53 Norman Road, London, SE10 9QF
Tel: +44 (0) 208-858-1888
Support: service@elitech.uk.com
Website: www.elitecheu.com
Elitech Brazil Ltda
R.Dona Rosalina,90 – Lgara, Canoas – RS
92410-695,Brazil
Tel: +(55)S1-3939-8634
Sales: brasil@e-elitech.com
Website: www.elitechbrasil.com.br
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>